跳至主要内容
临床试验/NCT04704804
NCT04704804已完成不适用

Feasibility of MRI Workflow Alone in External Radiotherapy for the Treatment of Brain and Prostate Tumors

Institut Cancerologie de l'Ouest1 个研究点 分布在 1 个国家目标入组 94 人开始时间: 2020年7月24日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
94
试验地点
1
主要终点
describe the differences in volumetric and dosimetric accuracy between potential planning from MRI alone by CT-synthetics generation and standard planning from CT

研究概览

简要总结

In radiotherapy, Magnetic Resonance Imaging (MRI) is used as a complement to the CT scanner because it provides better tissue contrast and therefore more precise delineations without the need for additional irradiation. However, MRI does not allow the definition of the electronic densities of the tissues necessary for dose calculation.

In this work, we sought to measure the feasibility of a method for generating CT-synthetic images from MRI in terms of dosimetric and geometrical precision for the purpose of MRI workflow alone (see diagram). The cerebral sphere and the prostate are the two tumor locations considered. All patients will have a planning CT (reference) and an MRI in the treatment position. The contours of the structures will be contoured by a radiotherapist on both the MRI and the reference CT. Synthetic CTs will be generated from the MRI with the method of automatic assignment of densities in five classes. The volumes bypassed and the dosimetries performed will be compared. A study of the quality of the images generated from MRI for dose calculation and images for the verification of per-treatment positioning will be performed.

详细描述

This is a prospective single-center dosimetry study that exhaustively included brain tumor and prostate cancer patients treated at the ICO Site d'Angers by external radiotherapy and prior to which they were given an MRI and a simulation CT in treatment position over a 12-month period.

For patients who agree to participate in the study, CT-synthetic images will be generated from the MRI images by automatic assignment of densities (5 classes).

Reference CT images from CT and synthetic CT images from MRI will be available for comparison for all eligible patients.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Age ≥ 18 years old
  • •Male or Female with a (primary) brain tumour or Male with cancer and localized (non-metastatic) prostate cancer
  • •Patient having benefited from a planning MRI scan in treatment position performed according to the new acquisition modalities (allowing the generation of CT-synthetics by automatic assignment of densities) performed since January 2020 and a planning scanner in treatment position prior to external radiotherapy.
  • •Good general condition (SP < 3)

排除标准

  • •Excluded forms of the disease,
  • •MRI-specific contraindications (claustrophobia, foreign bodies)
  • •Obesity preventing the placement of equipment (contention/antennae)
  • •Poor general condition (SP > or = 2) preventing the patient from standing on the table -

结局指标

主要结局

describe the differences in volumetric and dosimetric accuracy between potential planning from MRI alone by CT-synthetics generation and standard planning from CT

时间窗: 3 month

Comparison of the contours of target volumes and organs at risk and comparison of dose distributions (dosimetries)

次要结局

  • Measurement of the quality of images generated from MRI for dose calculation and images for verification of per-treatment positioning relative to the reference CT in an MRI-only workflow objective.(3 month)

研究者

发起方
Institut Cancerologie de l'Ouest
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验

Feasibility of MRI Workflow Alone in External... | 临床试验