跳至主要内容
临床试验/NCT02516163
NCT02516163已完成不适用

A Prospective, Non-randomized,Study of the Clinical Outcomes of Participants That Receive the Stryker Triathlon Total Knee System for Total Knee Arthroplasty Implanted Using ShapeMatch® Cutting Guides: Sub-Study A

Stryker South Pacific0 个研究点目标入组 55 人开始时间: 2010年12月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
55
主要终点
Repeatability of Cutting Guide Position

研究概览

简要总结

This is a prospective, non-randomized, study of the clinical outcomes of participants that receive the Stryker Triathlon® Total Knee System for Total Knee Arthroplasty implanted using ShapeMatch® Cutting Guides.

详细描述

This is a prospective, non-randomized, study of the clinical outcomes of participants that receive the Stryker Triathlon® Total Knee System for Total Knee Arthroplasty implanted using ShapeMatch® Cutting Guides. Sub-study A aims to quantify the reproducibility of intra-operatively positioning the cutting guides onto the affected femoral and tibial joint surfaces.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
50 Years 至 90 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • The patient is a male or non-pregnant female between the ages of 50-
  • The patient requires a primary total knee replacement and is indicated for computer-assisted surgery.
  • The patient has a primary diagnosis of osteoarthritis (OA).
  • The patient has intact collateral ligaments.
  • The patient is able to undergo MRI scanning of the affected limb.
  • The patient has signed the study specific, HREC-approved, Informed Consent document.
  • The patient is willing and able to comply with the specified pre-operative and post-operative clinical and radiographic evaluations.

排除标准

  • The patient has a history of total, unicompartmental reconstruction or fusion of the affected joint.
  • The patient has had a high tibial osteotomy or femoral osteotomy.
  • The patient is morbidly obese (BMI ≥ 40).
  • The patient has a deformity which will require the use of stems, wedges or augments in conjunction with the Triathlon Total Knee System.
  • The patient has a varus/valgus malalignment ≥ 15° (relative to mechanical axis).
  • The patient has a fixed flexion deformity ≥ 15°.
  • The patient has a neuromuscular or neurosensory deficiency, which would limit the ability to assess the performance of the device.
  • The patient has a systemic or metabolic disorder leading to progressive bone deterioration.
  • The patient is immunologically suppressed or receiving steroids in excess of normal physiological requirements.
  • The patient has a cognitive impairment, an intellectual disability or a mental illness.
  • The patient is pregnant.
  • The patient has metal hardware present in the region of the hip, knee or ankle (as this is known to create geometrical distortion in the region of the implant).
  • The patient has any known contraindications for undergoing assessment by MRI (e.g. ferrous implants, metallic clips, magnetically activated implanted devices such as cardiac pacemakers, etc).

结局指标

主要结局

Repeatability of Cutting Guide Position

时间窗: Intraoperative - participants were followed for the duration of the operation, an average of 1 hour and 50 minutes.

Repeatability of cutting guide position on the distal femur and proximal tibia assessed by repeated measures using computer navigation system for total knee replacement, assessed intra-operatively. Placement of the cutting guides by the surgeon was determined by recording the position of the cutting guide when placed by the same surgeon multiple times. The intraclass correlation coefficient (ICC) was calculated for each positioning parameter. This included femoral and tibial varus/valgus,flexion/extension, medial resection, lateral resection and rotation. ICC agreement categories:\>0.75 excellent agreement; 0.75-0.4 good or fair agreement; \<0.4 poor agreement.

次要结局

未报告次要终点

研究者

申办方类型
Industry
责任方
Sponsor

相似试验