跳至主要内容
临床试验/NCT04712253
NCT04712253已完成不适用

Multicenter Retrospective International Study to Evaluate Outcomes and Safety of Patients Undergoing ERCP Using a Single-use Cholangioscope (SpyGlass DS II) and Single-use Duodenoscope (Exalt) - The MESE Study

Istituto Clinico Humanitas1 个研究点 分布在 1 个国家目标入组 50 人开始时间: 2021年1月27日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
50
试验地点
1
主要终点
Technical success

研究概览

简要总结

Since its introduction more than 40 years ago, endoscopic retrograde cholangiopancreatography (ERCP) has fundamentally changed the treatment of biliopancreatic diseases. Since late 1970s there have been sporadic reports of nosocomial infections linked to endoscopic procedures, the majority caused by inadequate reprocessing of endoscopes. Infections due to multidrug-resistant organisms (MDROs) however have increasingly become a concern in health care, including in gastrointestinal (GI) endoscopy. Since 2010, reports of individual cases and serial outbreaks of MDRO infections associated with ERCP have been published worldwide. This is because, unlike a gastroscope or colonoscope, the duodenoscope is a complex instrument with unique mechanical features incorporated at the distal tip. This includes a recessed space containing an elevator, a wire cable that moves the elevator, working channel, and most recently, a seal that prevents contamination of the elevator wire channel. This complex design creates hard-to-reach areas that make optimal mechanical cleaning and disinfection difficult. With the aim of overcoming these issues, a single-use duodenoscope (EXALT Model D, Boston Scientific Corporation, Marlborough, Massachusetts, USA) has been developed in the United States of America (USA) and approved by the United States Food and Drug Administration (FDA) for clinical use in December 2019. Different studies evaluating this new device, including randomized clinical trials (RCTs), have already been published, which have confirmed that single-use duodenoscopes represent an alternative to reusable duodenoscopes for performing low-complexity ERCP procedures in experienced hands.

Digital Single Operator Cholangioscopy (D-SOC) using the single use Spyglass DS II (Boston Scientific Corporation, Marlborough, Massachusetts, USA) is a diagnostic and therapeutic modality which allows for direct endoscopic visualization of the biliopancreatic ductal system.

The principal diagnostic indication of D-SOC are bile duct or pancreatic strictures and unclear filling defects, adding direct endoscopic appearance data to biopsy sampling or brush cytology in order to improve the diagnostic yield.

The major therapeutic indication for D-SOC is lithotripsy for difficult biliary and pancreatic stones.

However, cholangioscopy increased the risk of post ERCP cholangitis. Bacteremia was suggested to be specifically related to cholangioscopy in 13.9% of 72 patients, based on serial blood samplings, and to be associated with biopsy sampling and strictures.

For this reason, the recent European Society of Gastrointestinal Endoscopy (ESGE) guideline suggests that patients should be considered to be at high risk for post-ERCP cholangitis when cholangioscopy is performed.

Presently, there are very few clinical reports about technical and clinical outcome of ERCPs performed with single use duodenoscope and there is complete lack of data about efficacy, safety and adverse events of the combination of the new single-use duodenoscope and the Spyglass DS II.

The aim of this multicentric retrospective study was to evaluate the technical success, clinical outcome and rate of adverse events of this procedure.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Retrospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • patients that required an ERCP with cholangioscopy performed with the single-use EXALT duodenoscope in combination with the Spyglass DS II

排除标准

  • Age < 18
  • Lack of follow-up data (30 days at least)
  • Less than 3 cases performed during the study period

结局指标

主要结局

Technical success

时间窗: 6 Months

Technical success defined as the ability to successfully complete the entire procedure (completed without cross-over to a reusable duodenoscope) with the intended diagnostic or therapeutic maneuvers according to the clinical indication (i.e. stone fragmentation/removal, biopsies from the targeted tissue, etc)

Clinical Outcome

时间窗: 6 Months

Numbers of adverse events

次要结局

未报告次要终点

研究者

发起方
Istituto Clinico Humanitas
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验