跳至主要内容
临床试验/NCT07041697
NCT07041697已完成不适用

Application of Photobiomodulation Therapy by LED Using a Combined Red and Near-infrared Light Spectrum Improves the Vascular Function of the Radial Artery in Vitro

University of Sao Paulo2 个研究点 分布在 1 个国家目标入组 30 人开始时间: 2023年1月12日最近更新:

试验速览

阶段
不适用
状态
已完成
入组人数
30
试验地点
2
主要终点
Diameter of Isolated Radial Artery Rings (2 mm)

研究概览

简要总结

LED photobiomodulation therapy (PBMT) is widely recognized for its beneficial effects in several clinical conditions; however, its potential in modulating vascular function is not yet fully established. Objective: This study aimed to evaluate the application of PBMT by LED (light-emittion diode) using a combined red and near-infrared light spectrum, with a focus on improving the vascular function of the radial artery in vitro. Methodology: A total of 30 radial artery segments were studied and divided into three groups of 10 segments: the PBMT LED group combined with red and infrared light (R + IR), the red light (R) group, and the infrared light (IR) group. Prior to light irradiation at wavelengths of 650 nm and 940 nm, vascular function in these segments was pharmacologically inhibited using L-NAME. The drugs phenylephrine, acetylcholine, and sodium nitroprusside were used to determine if irradiation could restore the inhibited vascular functions. Superoxide anion levels, an important reactive oxygen specie (ROS), were measured using a chemiluminescence assay with lucigenin. The bioavailability of nitric oxide was evaluated using a Griess Reagent Kit assay, while nitric oxide production was assessed through the DAF fluorescence assay. The vascular inflammation was determined by the Intercellular Adhesion Molecule 1 (ICAM-1) expression.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Crossover
主要目的
Prevention
盲法
None

入排标准

年龄范围
20 Years 至 60 Years(Adult)
性别
All
接受健康志愿者

入选标准

  • Patients undergoing coronary artery bypass grafting using the radial artery

排除标准

  • Patients with poorly compliant radial arteries or those who underwent coronary artery bypass grafting without use of the radial artery were excluded from the study

结局指标

主要结局

Diameter of Isolated Radial Artery Rings (2 mm)

时间窗: 12 months

Description of Primary Outcome Measure(s): The primary outcome of this study is the evaluation of vascular compliance during vasodilation of isolated radial artery rings (2 mm in diameter), with a specific focus on the effects of LED photobiomodulation on arterial function.

次要结局

  • Evaluation of reactive oxygen species (ROS)(12 months)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

André Timóteo Sapalo

Clinical Professor

University of Sao Paulo

研究点 (2)

Loading locations...

相似试验