Comparison of Three Cannulas for Hysterosalpingography: A Prospective, Randomized Study
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 114
- 试验地点
- 2
- 主要终点
- pain scores
研究概览
简要总结
The aim of this study is to compare the three commonly used hysterosalpingography (HSG) injection devices on the basis of patient pain perception, total fluoroscopic and procedural time, and side effects in a prospective, randomized study. An important and novel secondary outcome is the comparison of the quality of images obtained with these three devices. The investigators hypothesize that the balloon catheter and cervical vacuum cup will be less painful than the acorn tipped cannula and that there will be no difference in image quality between the three groups.
详细描述
This study is a prospective, randomized trial of women undergoing HSG as part of their infertility evaluation. At the time of scheduling, the patient will be randomized to either the cervical vacuum cup, balloon catheter (H/S catheter set, UA Medical, Biotech America), or the acorn-tipped cannula using stratified blocked randomization. 100 subjects will be randomized to one of the three cannulas. Patients will be stratified into 4 groups representative of the four reproductive endocrinologists in order to overcome any potential interoperator bias.
Four reproductive endocrinologists will perform the HSG procedures in a standardized fashion. Fluoroscopy will ensure proper location of the cannula and check for uterine filling of contrast. Digital images will document tubal filling and spilling of contrast. The patient will be rolled to right and left side to confirm free spillage of contrast in the peritoneal cavity. The last image will be taken after the balloon tip is deflated or the cannulas are removed to best evaluate the lower uterine segment.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Diagnostic
- 盲法
- Double (Participant, Outcomes Assessor)
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- Female
- 接受健康志愿者
- 否
入选标准
- •Women undergoing HSG at an academic medical center
排除标准
- •Contrast media allergy
- •Prior LEEP (Loop Electrosurgical Excision Procedure) or other cervical procedure
- •Contraindication to NSAID use
- •Known active pelvic infection
- •Active vaginal bleeding
结局指标
主要结局
pain scores
时间窗: 15 minutes
次要结局
- diagnostic quality of images obtained(1 month)
- the total duration of the procedure(15 minutes)
- direct fluoroscopic time(15 minutes)
- rates of vasovagal reaction(15 minutes)