临床试验/NCT06417021
NCT06417021已完成不适用

The Position of the Ultrasound Machine in the Placement of the Central Venous Catheter: a Randomized Controlled Study

University of Padova2 个研究点 分布在 1 个国家目标入组 239 人开始时间: 2024年5月25日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
239
试验地点
2
主要终点
Time to correct CVC position

研究概览

简要总结

The study will compare two different positions of the ultrasound machine during simulated CVC positioning.

The position of the ultrasound machine will be randomized. Group A will perform the procedure with the ultrasound monitor facing them, while subjects randomized to group B will perform the procedure with the ultrasound machine positioned at a 90° angle to their visual axis.

详细描述

We will recruit medical trainees affiliated with the 'Anesthesia and Intensive Care' and 'Emergency Medicine' schools. Data collected for each participant will include: age, gender, specialty school, year of specialization training, expertise in using ultrasound for ultrasound-guided procedures. Once informed consent is obtained, subjects will be divided through simple randomization (a list generated in advance with Excel and subjected to the opaque envelope method) into two groups: A and B. All subjects will be asked to perform CVC placement using the simulator through an 'oblique in-plane' approach. Subjects randomized to group A will perform the procedure with the ultrasound monitor facing them, while subjects randomized to group B will perform the procedure with the ultrasound machine positioned at a 90° angle to their visual axis.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Other
盲法
Single (Outcomes Assessor)

盲法说明

A clip of the ultrasound procedure will be saved and reviewed by a blind assessor that will value the quality of the procedure

入排标准

性别
All
接受健康志愿者

入选标准

  • 'Anesthesia and Intensive Care' and 'Emergency Medicine' residents
  • Informed consent

排除标准

  • 未提供

结局指标

主要结局

Time to correct CVC position

时间窗: baseline

Investigators will measure time needed to correctly perform the procedure in seconds. The chronometer will be started when the participant takes the ultrasound probe and will be stopped when the guidewire will be correctly placed

次要结局

  • Needle tip visualization(baseline)
  • Complications(baseline)
  • Success of the procedure(10 minutes from the baseline)

研究者

发起方
University of Padova
申办方类型
Other
责任方
Principal Investigator
主要研究者

Alessandro De Cassai

Principal Investigator

University of Padova

研究点 (2)

Loading locations...