跳至主要内容
临床试验/NCT00693030
NCT00693030Unknown4 期

In-Vivo Vascular Response of Sirolimus-,Paclitaxel- and Zotarolimus-Eluting Stents in Long Lesions Requiring Overlapping. A Prospective, Randomized, Controlled Study Using Optical Coherence Tomography

A.O. Ospedale Papa Giovanni XXIII2 个研究点 分布在 1 个国家目标入组 77 人开始时间: 2006年8月1日最近更新:
适应症

试验速览

阶段
4 期
发起方
入组人数
77
试验地点
2
主要终点
Number of uncovered and/or malapposed stent struts at overlapping versus non overlapping sites in drug eluting vs bare metal stents

研究概览

简要总结

Increasing lesion complexity in percutaneous coronary interventions (PCI) has warranted the use of overlapping drug-eluting stents. Whether the substantial impairment of arterial healing observed at sites of overlap in preclinical pathologic studies persists in patients undergoing PCI is unknown. Consecutive patients with long lesions in native coronary vessels requiring stents in overlap are prospectively randomized to receive multiple sirolimus-,paclitaxel polymer-or zotarolimus eluting stents versus bare metal stents. The completeness of stent struts coverage and/or late malapposition are evaluated by Optical Coherence Tomography at 6 months follow-up

详细描述

If overlapping drug-eluting stents provide increased vessel toxicity is not known. Given the association of delayed healing and incomplete endothelialization observed in animal and human autopsy studies at overlapping sites it is unclear why most patients do well with multiple DES implanted. OCT detecs smaller degrees of in-stent neointima more accurately than IVUS and might be a useful method for identify strut coverage and/or malapposition.

Patients if eligible on the basis of clinical and angiographic criteria, are randomized (2:2:2:1) to receive multiple TAXUS Libertè™ vs Cypher Select™ vs Endeavor™ vs Libertè BM stents, in overlap. Stent implantation are done accordingly to the normal interventional practice. QCA and IVUS are performed at the end of optimal stents placement per visual judgement (residual stenosis < 10%, TIMI 3 flow). Stent, lumen size and volume as well as complete stent strut apposal will be determined by IVUS analysis. Clinical follow-up will take place at 1 month (±1 week), 6 months (±2 weeks) and 1 year (±2 weeks). At 6-months follow-up all patients will undergo a quantitative coronary angiography (QCA), IVUS and Optical Coherence Tomography (LightLab OCT Imaging M2, automated pull back and flushing combination)assessments.

OCT images will be acquired at 15-30 frames per second. Blind corelab quantitative strut by strut analysis will be performed using a novel dedicated software at each 0.5 mm section. The following OCT variables will be evaluated:number of visualized strut per section, mean-max neointimal thickness per section, % struts well apposed with neointima at overlapping vs non overlapping sites, % struts without neointima, % struts malapposed, rate of > 30% uncovered struts/total number of struts per section.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Native coronary artery disease with ≥ 75% diameter stenosis
  • Lesion length ≥ 20 mm,
  • Vessel size in between 2.5 and 3.5 mm.
  • Multiple, overlapped DES vs BMS placement (intention to overlap ≥ 4 mm)
  • Signed patient informed consent

排除标准

  • left main coronary artery disease,
  • lesions in coronary artery bypass grafts,
  • acute myocardial infarction,
  • poor cardiac function as defined by left ventricular global ejection fraction ≤ 30%.
  • allergy to aspirin and or clopidogrel/ticlo,
  • renal failure with creatinine value > 2.5,
  • no suitable anatomy for OCT scan

结局指标

主要结局

Number of uncovered and/or malapposed stent struts at overlapping versus non overlapping sites in drug eluting vs bare metal stents

时间窗: 6 months

次要结局

  • Ischemia Driven Target Vessel Failure(12 months)
  • Number of uncovered and/or malapposed stent struts at overlapping sites in sirolimus-, paclitaxel- or zotarolimus eluting stents(6 months)