NCT04806607已完成不适用
19Gauge Fine Needle Biopsy (FNB) Versus 22Gauge FNB for Endoscopic Ultrasound Guided Liver Biopsy (EUS-LB): A Randomized Prospective Trial
适应症
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 42
- 试验地点
- 2
- 主要终点
- Length of Longest Piece
研究概览
简要总结
To determine the adequacy of EUS-LB using a 19G core needle compared to a 22G core needle in a prospective randomized study.
详细描述
The 19Gauge core and 22Gauge core needles have both been used for EUS-LB with good success. Previous studies have reported good safety and tissue adequacy with both the needles, but the head-on comparison between these two needles is lacking.
This is a prospective randomized trial comparing the biopsy specimen adequacy of 19Gauge versus 22Gauge core needles for EUS-LB.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 89 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patients undergoing EUS-LB
- •Platelet Count > 50,000
- •International normalized ratio (INR) < 1.5
- •Age > 18 years of age
- •Non-Pregnant Patients
排除标准
- •Age < 18 Years of Age
- •Pregnant Patients
- •Inability to obtain consent
- •Anticoagulants or anti-platelet agents (excluding aspirin) within the last 7 -10 days
- •Platelet count < 50,000
- •Presence of Ascites
- •Known Liver Cirrhosis
结局指标
主要结局
Length of Longest Piece
时间窗: Up to 5 Days
Length of the longest piece of the liver tissue obtained
次要结局
- Adverse Events and Serious Adverse Events(7 to 10 Days Post Procedure)
- Aggregate Specimen Length(3 to 5 Days)
- Degree of Fragmentation(3 to 5 Days)
- Number of Portal Tracts in the Specimen(3 to 5 Days)
研究者
David L. Diehl
Principal Investigator
Geisinger Clinic
研究点 (2)
Loading locations...
相似试验
已完成
不适用
EUS GUIDED Transduodenal Biopsy Using the 19G FlexAbdominal NeoplasmsNCT02307253Catholic University of the Sacred Heart246
已完成
不适用
Comparison of 22-gauge and 19-gauge Aspiration Needle During EBUS-TBNALung CancerNCT02813603University Hospital, Essen100
Unknown
不适用
Comparing of a 22G EUS Procore Fine Needle Biopsy Device and a 20G EUS Procore Fine Needle Biopsy DevicePancreas NeoplasmsNCT03803930Huazhong University of Science and Technology1,224
已完成
3 期
Evaluation of the new 22-gauge EUS guided Biopsy Needle (Acqiure) Comparing to another new 20-gauge FNA needle with forward-cutting bevel (ProCore) in Patients With Autoimmune Pancreatitis : A Prospective Randomized, Controlled Multicenter Studytype 1 autoimmune pancreatitisJPRN-UMIN000027668Bilio-Pancreatic Stenting study group110
已完成
不适用
Evaluation of 19-gauge vs 21-gauge EBUS TBNA in Assessing Thoracic LymphadenopathyEnlarged Lymph Nodes (Excluding Infective)NCT03657849HealthPartners Institute60
