International Multicenter Study of the Navitor/Navitor Vision Transcatheter Aortic Valve Platform (The Intensive Study)
试验速览
- 阶段
- 不适用
- 状态
- 招募中
- 发起方
- 入组人数
- 1,000
- 试验地点
- 1
- 主要终点
- All-Cause Mortality
研究概览
简要总结
INTENSIVE is a prospective, single-arm, multi-center, international, investigator-initiated study of the Navitor/Navitor Vision Transcatheter Aortic Valve (Navitor/Navitor Vision Valve) in patients with symptomatic, severe native aortic stenosis to monitor the outcomes of this valve in a real-world clinical setting.
详细描述
This comprehensive data collection across 25 interventional centers, aligned with standard clinical care practices, seeks to provide an objective benchmark for current TAVR practice.
The Navitor System includes the Navitor Transcatheter Aortic Valve (23 mm, 25 mm, 27 mm, 29 mm, and 35 mm), FlexNav Delivery System (small and large), and Navitor Loading System (small, large, and LG+). The FlexNav Delivery System (small and large) is commercially available in Europe. The 23 mm, 25 mm, 27 mm, 29 mm, and 35 mm valves and their loading systems are currently CE marked.
The Navitor Valve maintains several design features of the first-generation Portico Valve including the same valve sizes and range of use (except for the addition of the 35 mm valve to expand the use range), open stent cell design to provide easy coronary access and blood flow, repositionable with the ability to re-sheath and retrieve, leaflets derived from pericardial bovine tissue, and intra-annular placement of leaflets/cuff within the stent frame for early valve function to maintain hemodynamic stability during implantation.
The Study will enroll subjects that, after comprehensive Heart Team evaluation, are scheduled for treatment with the Navitor/Navitor Vision Valve according to the standard of care at up to 25 experienced TAVI implant centers across Europe and the UK. All sites must either have prior Portico or Navitor/Navitor Vision TAVI system experience. Subjects who provide informed consent for the collection of their clinical data in this Study will undergo Navitor/Navitor Vision Valve implantation via a transfemoral or alternative access (subclavian or axillary) approach using the site's anesthesia protocol for TAVI procedures.
In the Study, the point of enrollment is defined as signing of informed consent, whereas the point of registration is defined as the insertion of the FlexNav Delivery System (loaded with a Navitor/Navitor Vision Valve) into the subject's vasculature (the subject is considered to have undergone an attempted Navitor/Navitor Vision Valve implantation at this point). Only registered subjects will be included in the analysis.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Subject is referred to undergo TAVI with a Navitor/Navitor Vision valve according to the local Heart Team. The Heart Team determines the indication for TAVI with Navitor/Navitor Vision before possible enrolment and independently of the study.
- •Subject is of legal age for consent in the host country.
- •Subject has been informed of the nature of the study, agrees to its provisions, and has provided written informed consent as approved by the Ethics Committee (EC) of the respective clinical site.
排除标准
- •Pregnant or nursing subjects
- •Need for emergency surgery for any reason
- •Contraindications to Navitor/Navitor Vision TAVI according to the IFU:
- •Any sepsis, including active endocarditis
- •Any evidence of left ventricular or atrial thrombus
- •Vascular conditions (i.e., stenosis, tortuosity, or severe calcification) that make insertion and endovascular access to the aortic valve impossible
- •Non-calcified aortic annulus
- •Any leaflet configuration other than tricuspid
- •Inability to tolerate antiplatelet/anticoagulant therapy
- •Incapacitated individuals, defined as persons who are mentally ill, mentally handicapped, individuals with severe dementia or individuals without legal authority
- •Individuals who are unable to read or write
研究组 & 干预措施
Aortic Stenosis Patients
This Study will enroll subjects of all genders who have symptomatic severe AS, either in a native valve or in a surgical bioprosthetic valve, and who have an indication for TAVI. The latter may also be predominantly regurgitant and remain suitable for enrolment. Subjects must meet all general eligibility criteria for the TAVI procedure and provide written informed consent before sites collect any clinical data for this Study.
The operative risk determination of study candidates will be done by the local heart team. The assessment of surgical risk will include the Society of Thoracic Surgeons (STS) Adult Cardiac Surgery Risk Calculator score and/or EuroSCORE II, indices of frailty, and comorbidities not captured by risk calculators, as described below, and current TAVI practice guidelines.
结局指标
主要结局
All-Cause Mortality
时间窗: 12 months
The primary endpoint is all-cause mortality at 12 months after the index Navitor/Navitor Vision implantation procedure.
次要结局
- Valve Academic Research Consortium 3 (VARC-3) event definitions(30 days and 12 months)
- Valve Academic Research Consortium 3 (VARC-3) event definitions(30 days, 3 months, and 12 months)
- Valve Academic Research Consortium 3 (VARC-3) event definitions(30 days, 12 months and annually through 5 years)
