Intra-operative Evaluation of the Glenoid Implant Position With Structured Light

Sunnybrook Health Sciences Centre1 个研究点 分布在 1 个国家目标入组 14 人开始时间: 2021年11月19日最近更新:
适应症

试验速览

阶段
不适用
入组人数
14
试验地点
1
主要终点
Identify accuracy of the structured light computer vision system

研究概览

简要总结

Positioning of the glenoid component is one of the most challenging steps in shoulder replacement surgery. Prosthesis longevity and functional outcomes are considered highly dependent on accurate positioning. Currently, there are no adequate means to verify the position of the glenoid component during surgery which is a significant impediment to accurate positioning. We propose a non-interventional study to validate a novel technology for verifying the position of the glenoid component during shoulder replacement surgery.

详细描述

Positioning of the glenoid component is one of the most challenging steps in shoulder replacement surgery. In this study, we are testing a new method of checking the glenoid component position using an optical light 3D scanner for both total and reverse total shoulder replacements. Currently, the position of the glenoid component is verified by the operating surgeon visually and there is no routine imaging to verify the position of the glenoid component during surgery.

Participants in this study will have a 3D optical image of their glenoid bone taken during the surgical procedure. Taking this image will require less than 3 minutes and the image will only include their surgical wound (no facial features or other identifying features will be taken in the images). Two to six weeks after the surgery, the study participants will have CT scan of their replaced shoulder. This will allow the researchers to measure the accuracy of the new imaging system.

It is anticipated that about 14 people will participate in this study at Sunnybrook. The length of this study for participants is 6 weeks. The entire study is expected to take about 1 year to complete and the results should be known 6 months after study completion.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Cross Sectional

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Greater than 18 years of age.
  • Scheduled to undergo total shoulder arthroplasty surgery.
  • Scheduled pre-operative CT imaging of the shoulder and the surgical plan includes open exposure of the glenoid.

排除标准

  • Previous shoulder surgery involving the glenoid.
  • No clinically indicated pre-operative CT imaging.
  • Pregnancy (current or planned).
  • Current or planned participation in other research, or having a clinical condition that would result in cumulative annual radiation exposure exceeding the regulatory limit (30 mSv) from all sources.

结局指标

主要结局

Identify accuracy of the structured light computer vision system

时间窗: Surgical timepoint

The primary study outcome will be the accuracy of the structured light computer vision system. The outcome is a single measure quantified by the difference in predicted and actual position of the glenoid implant. The measure of the difference is a combination of version error (degrees), inclination error (degrees), and offset error (mm).

次要结局

  • Early post-operative complications (evaluated at 3 months follow-up from chart review)(3 months after surgery)
  • Operative delay for imaging (seconds)(Surgical timepoint)
  • Computer vision system image processing time (seconds)(Surgical timepoint)
  • Intra-operative complications(Surgical timepoint)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Dr. Robin Richards

Orthopaedic Surgeon, Division of Orthopaedic Surgery

Sunnybrook Health Sciences Centre