跳至主要内容
临床试验/NCT07753577
NCT07753577尚未招募不适用

Clinical Trial to Evaluate the Effectiveness of Liver Shear Wave Quantization Detector Spleen Stiffness Value in the Diagnosis of Esophageal Varices

Beijing Friendship Hospital0 个研究点目标入组 246 人开始时间: 2026年8月20日最近更新:
适应症

试验速览

阶段
不适用
状态
尚未招募
入组人数
246
主要终点
The results of esophagogastric duodenoscopy (EGD) were used as the gold standard to evaluate the diagnostic performance of spleen stiffness value detected by liver function shear wave quantization detector Pro9000X for esophageal varices (EV) in patients

研究概览

简要总结

Esophageal variceal bleeding is one of the serious and life-threatening complications of chronic liver disease (CLD). Studies have shown that the prevalence of esophageal varices (EV) in patients with liver cirrhosis is about 50%-60%. The annual incidence of variceal bleeding in these patients is about 5%-15%, and the rebleeding rate can reach 30%-40% within 6 weeks after the first bleeding. The 6-week mortality related to variceal bleeding is as high as 10%-20%, which seriously threatens the life safety of patients with liver disease. Clinically, esophagogastroduodenoscopy (EGD) is the gold standard for the diagnosis and grading of esophageal varices. However, EGD is an invasive examination, which has certain application limitations such as related complications and high cost, which limits the promotion and application of this technology.

Therefore, there is an urgent need for an accurate, convenient and non-invasive method for esophageal varices. To address this clinical pain point, Baveno VII guidelines state that spleen stiffness measurement (SSM) based on vibration-controlled transient elastography (TE) can be used as a noninvasive marker to predict esophageal varices (EV). Several studies have shown that SSM measured by TE has good diagnostic performance in relation to the occurrence and severity of esophageal varices. A study involving 191 patients with liver disease showed that spleen stiffness was significantly higher in patients with varices than in those without varices (63.69 vs 47.78 kPa, P<0.0001), and the AUC of SSM for the diagnosis of EV was 0.74. In another study involving 260 patients with chronic liver disease, the AUC of SSM was 0.728 (95% CI: 0.665-0.791) for EV and 0.780 (95% CI: 0.714-0.846) for high-risk varix (HRV). The above results indicate that SSM has good clinical value in the prediction of EV.

Pro9000X, a liver function shear wave quantization detector based on vibration control TE, has been developed by Wuxi Hisiel Medical Technology Co., LTD. The device integrates ultrasound image positioning and TE function, aiming to achieve rapid, quantitative and non-invasive detection of liver stiffness measurement (LSM) and SSM. The results of EGD examination were used as the gold standard to evaluate the diagnostic performance of the spleen stiffness value detected by Pro9000X in patients with chronic liver disease, and the main evaluation indicators were the sensitivity and specificity of EV diagnosis. Secondary evaluation included AUROC, optimal cut-off value and diagnostic value of high-risk EV.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Age over 18 years old, male or female;
  • patients with clinically diagnosed chronic liver disease, including hepatitis C virus (HCV) infection, hepatitis B virus (HBV) infection, fatty liver disease, autoimmune liver disease, and alcoholic liver disease *;
  • Liver stiffness measurement (LSM) ≥10kPa during screening or within one month before screening [4];
  • able to communicate well with the investigators, understand and comply with the requirements of the study;
  • Informed consent was signed voluntarily.

排除标准

  • alanine aminotransferase (ALT) or aspartate aminotransferase (AST) ≥250 U/L;
  • complicated with jaundice (serum total bilirubin ≥50 μmol/L);
  • complicated with important organ diseases (except liver) or serious systemic diseases (such as malignant tumors and HIV);
  • after liver transplantation or TIPS;
  • after splenectomy, splenic embolization or other portasystemic shunts;
  • patients with moderate-to-large amount of ascites;
  • unstable condition in the acute stage of esophageal variceal bleeding;
  • combined with liver malignant tumors;
  • patients with non-cirrhotic portal hypertension, Budd-Chiari syndrome and other hepatic vascular diseases; Acute or chronic portal vein thrombosis;
  • unhealed wounds or scars in the left abdomen were not suitable for ultrasound examination;
  • pregnant women;
  • Other conditions judged by the investigators as not suitable for participating in the study.

结局指标

主要结局

The results of esophagogastric duodenoscopy (EGD) were used as the gold standard to evaluate the diagnostic performance of spleen stiffness value detected by liver function shear wave quantization detector Pro9000X for esophageal varices (EV) in patients

时间窗: day 1: Screening period visit(Sign the informed consent form, meet the inclusion and exclusion criteria, et al) day 2-day 30: Trial visit during the period of experimentation (EGD and Pro9000X Spleen Hardness Examination) day 31: Pre-group visitation

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Hong You

Chief Physician, Principal Investigator

Beijing Friendship Hospital

相似试验