跳至主要内容
临床试验/NCT03782571
NCT03782571已完成不适用

Influence of Lens Design on Particulate Exchange in the Post-lens Tear Film

Johnson & Johnson Vision Care, Inc.2 个研究点 分布在 1 个国家目标入组 34 人开始时间: 2018年11月16日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
34
试验地点
2
主要终点
Microsphere Clearance Rate

研究概览

简要总结

This is a 5-visit, controlled, bilateral, randomized, subject-masked, crossover (4 treatments x 4 period), non-dispensing study. Subjects will attend all study visits in their spectacle correction having not worn contact lenses on the day of the visit.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Treatment
盲法
Single (Participant)

入排标准

年龄范围
18 Years 至 40 Years(Adult)
性别
All
接受健康志愿者

入选标准

  • Potential subjects must satisfy all of the following criteria to be enrolled in the study:
  • The subject must read, understand, and sign the STATEMENT OF INFORMED CONSENT and receive a fully executed copy of the form.
  • The subject must appear able and willing to adhere to the instructions set forth in this clinical protocol.
  • The subject must be between 18 and 40 (inclusive) years of age at the time of screening.
  • The subject must own a wearable pair of spectacles and be willing to wear them to each study visit.
  • The subject must be an adapted soft contact lens wearer in both eyes, having successfully worn contact lenses in the last six months by self-report.
  • The subject must agree not to participate in other clinical research for the duration of this study.
  • The subject's refractive cylinder must be <-1.25DC in each eye.
  • The subject must have best corrected visual acuity of 0.20 logMAR or better in each eye.

排除标准

  • Potential subjects who meet any of the following criteria will be excluded from participating in the study:
  • Currently pregnant or breast feeding (self-reported).
  • Any systemic disease (e.g., Sjögren's Syndrome), infectious disease (e.g., hepatitis, tuberculosis), contagious immunosuppressive diseases (e.g., HIV), autoimmune disease (e.g. rheumatoid arthritis), or other diseases, by self-report, which are known to interfere with contact lens wear and/or participation in the study (at the Investigator's discretion).
  • Use of topical medication such as eye drops or ointment within 24 hours prior to the study visit.
  • Any history of anaphylaxis or severe allergy.
  • Any previous, or planned (during the course of the study) ocular surgery (e.g., radial keratotomy, PRK, LASIK, etc.)
  • Participation in any contact lens or lens care product clinical trial within 14 days prior to study enrollment
  • Employee or immediate family member of an employee of clinical site (e.g., Investigator, Coordinator, Technician)
  • They have any slit lamp findings of grade 3 or higher (e.g. corneal edema, corneal neovascularization, tarsal abnormalities, conjunctival injection) or findings of < Grade 3 which in the investigator's opinion would contraindicate contact lens wear.

结局指标

主要结局

Microsphere Clearance Rate

时间窗: Post microsphere application over a 30 minute period

The rate of microsphere clearance from the post-lens tear film was assessed by the C30 image analysis metric. Where bare eye was assigned, a droplet of microsphere suspension was applied directly onto the superior temporal conjunctiva. Where lens wear was assigned, the microsphere suspension was dispensed onto the posterior concave contact lens surface immediately prior to lens application. A series of digital images were taken over a 30-minute period (every minute for the first 10 minutes and then every 5 minutes for the next 20 minutes). Data transformed from the images were calculated by the C30 image analysis metric. Higher numbers represented greater clearance. The right eye was used to evaluate microsphere clearance.

Microsphere Uptake Rate

时间窗: Post microsphere application over a 10 minute period

The rate of microsphere uptake into the post-lens tear film was assessed by the U5 image analysis metric. Where bare eye was assigned, a droplet of microsphere suspension was applied directly onto the superior temporal conjunctiva. Where a lens was assigned the lens was applied and after a 10-minute settling period, a droplet of microsphere suspension was applied directly to the superior temporal conjunctiva. A series of digital images were taken over a 10-minute period (every minute for 10 minutes). Data transformed from the images were calculated by the U5 image analysis metric. Higher numbers represented greater uptake rate. The left eye was used to evaluate microsphere uptake.

次要结局

  • Lens Movement(Post microsphere application at 30-minute timepoint (OD); post microsphere application at 10-minute timepoint (OS))
  • Blink Rate(Baseline and the 30-minute post microsphere application time point in the right eye and at the 10-minute post microsphere application timepoint in the left eye.)
  • Corneal Curvature(Baseline)

研究者

申办方类型
Industry
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验