跳至主要内容
临床试验/NCT05350280
NCT05350280已完成不适用

Evaluation the Effects of Low-intensity Electrical Current on the Rate of Orthodontic Tooth Movement, and Dentoalveolar Changes During En-masse Retraction of Maxillary Anterior Teeth: A Randomized Controlled Clinical Trial)

Damascus University1 个研究点 分布在 1 个国家目标入组 38 人开始时间: 2018年8月20日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
38
试验地点
1
主要终点
Rate of retraction

研究概览

简要总结

Thirty-eight patients requiring extraction of maxillary first premolars and maximum anchorage to retract the upper anterior teeth will participate in the study. They will be divided randomly into two groups: electrical group and control group. In each group, en-masse retraction will be initiated after completion of the leveling and alignment phase via closed nickel-titanium coil springs applying 250 g of force per side, Mini-implants will be used as an anchor unit.

The dental changes will be detected using dental casts and to evaluate the rate of teeth retraction.

详细描述

Prior to enrollment of each subject into the study, they will be examined completely to determine the orthodontic treatment plan. The operator will inform them about the aim of the study and ask them to provide a written informed consent.

Self-drilling titanium mini-implants (1.6mm diameter and 8mm length) will be used. They will be inserted between the maxillary second premolar and first molar at approximately 8-10mm above the archwires at the mucogingival junction and will be checked for primary stability (mechanical retention). Then the maxillary first premolar will be extracted. The maxillary arch will be levelled and aligned. The rectangular stainless steel archwires (0.019" × 0.025") with anterior 8mm height soldered hooks distal to the canines will be inserted.

A removable device containing a small electrical circuit will be applied to each patient to supply the required electric current.

Each patient in the electrical group will be asked to wear the device for five hours a day until the completion of the retraction of the upper anterior.

(250-300) g force will be applied on each side using two NiTi springs attached between the mini-implants and the soldered hooks in a direction approximately parallel to the occlusal plane for conducting an en-masse retraction. The force level will be measured every 2 weeks. Retraction will be stopped when a class I canine relationship will be achieved and a good incisor relationship will be obtained.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single (Outcomes Assessor)

入排标准

年龄范围
16 Years 至 25 Years(Child, Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Adult healthy patients, Male and female, Age range: 15-27 years.
  • •Class II Division 1 malocclusion:
  • •Mild / moderate skeletal Class II (sagittal discrepancy angle ≤7)
  • •Overjet ≤10
  • •Normal or excessive facial height (Clinically and then cephalometrically assessed using these three angles: mandibular/cranial base angle, maxillary/mandibular plane angle and facial axis angle)
  • •Mild to moderate crowding ≤ 4
  • •Permanent occlusion.
  • •Existence of all the upper teeth (except third molars).
  • •Good oral and periodontal health:
  • •Probing depth < 4 mm
  • •No radiographic evidence of bone loss.
  • •Gingival index ≤ 1
  • •Plaque index ≤ 1

排除标准

  • •Medical problems that affect tooth movement (corticosteroid, nonsteroidal anti-inflammatory drugs (NSAIDs), ...)
  • •Presence of primary teeth in the maxillary arch
  • •Missing permanent maxillary teeth (except third molars).
  • •Poor oral hygiene or Current periodontal disease:
  • •Probing depth ≥ 4 mm
  • •radiographic evidence of bone loss
  • •Gingival index > 1
  • •Plaque index > 1
  • •Patient had previous orthodontic treatment

研究组 & 干预措施

Low-intensity electrical current (LIEC)

Experimental

A removable device containing a small electrical circuit will supply the required electric current for five hours a day until the completion the retraction of the upper anterior teeth.

干预措施: electric current (Device)

Traditional fixed orthodontic appliance

Active Comparator

The maxillary arch will be levelled and aligned. (250-300) g force will be applied on each side using two NiTi springs attached between the mini-implants and the soldered hooks in a direction approximately parallel to the occlusal plane for conducting an en-masse retraction.

干预措施: Traditional treatment (Device)

结局指标

主要结局

Rate of retraction

时间窗: The calculation of the rate of retraction will be done once the retraction procedures has finished. Completion of this procedure is expected to occur within 6 months in the experimental group and 8 months in the control group.

Assessment will be performed on study models. The amount of distance being retracted in millimeters will be divided by the duration of retraction in weeks to give an estimation of the retraction rate.

Change in Incisors' positions

时间窗: T0: 1 day before the beginning of retraction. T1: after 1 month (m) of retraction. T2: after 2 m of retraction. T3: after 3 m. T4: after 4 m. T5: at the end of retraction (expected to be within 6 m in the exp. group and 8 m in the control group)

Amount of distance being traveled by the retracted anterior teeth is going to be measured on study models taken at monthly intervals until the end of the retraction phase.

次要结局

  • Change in the inter-molar width(T0: 1 day before the beginning of retraction. T1: after 1 month (m) of retraction. T2: after 2 m of retraction. T3: after 3 m. T4: after 4 m. T5: at the end of retraction (expected to be within 6 m in the exp. group and 8 m in the control group))
  • Change in the inter-canine width(T0: 1 day before the beginning of retraction. T1: after 1 month (m) of retraction. T2: after 2 m of retraction. T3: after 3 m. T4: after 4 m. T5: at the end of retraction (expected to be within 6 m in the exp. group and 8 m in the control group))
  • Change in Molars' positions(T0: 1 day before the beginning of retraction. T1: after 1 month (m) of retraction. T2: after 2 m of retraction. T3: after 3 m. T4: after 4 m. T5: at the end of retraction (expected to be within 6 m in the exp. group and 8 m in the control group))

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...