Evaluation of the Erector Spinae Muscle Biomechanical Characteristics in Different Position and the Change After Receiving Myofascial Release.
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 30
- 试验地点
- 1
- 主要终点
- muscle stiffness of manual erector spinae myofascial realease
研究概览
简要总结
The purpose of this experiment is to evaluate whether MyotonPRO can quantify the changes in the muscle characteristics of the erector spinae in different postures and after myofascial relaxation, and to test the validity of the muscle tone tester.
详细描述
In clinical practice, manual muscle testing (MMT) and Modified Ashworth scale (MAS) grading systems are often used to assess muscle tension and tension. Although these methods are considered feasible, because these methods are mainly classified based on the subjective perception of the evaluator, the reliability and accuracy of the evaluation results are often questioned. Therefore, we should seek a way to objectively evaluate muscle tension with biomechanical properties and quantitative data to solve these deviations. MyotonPRO (Myoton AS, Tallinn, Estonia) is a tester that uses biomechanical principles to collect muscle tension status. This handheld muscle tension tester uses mechanical pressure and reaction force feedback to calculate through biomechanical conversion. The tone, stiffness and elasticity of the muscle are expressed as quantitative data. There have been many use reports showing that the muscle tone meter has the feasibility of quantifying muscle tone.
The erector spinae is one of the most important back muscles of the human body. After contraction, the entire spine can be erected, allowing the upper body to stand upright. When the posture changes, such as: sitting posture, hunchback, bending over, erector spinae will be stretched or continuously contracted due to different postures, resulting in changes in muscle characteristics. Therefore, if the erector spinae is used improperly for long-term poor posture, the erector spinae is easily damaged due to heavy burden, which can easily cause back pain. Myofascial release (myofascial release) is a soft tissue massage method that loosens the fascia with hands. By changing the mechanical properties of the muscles, it can loosen over-tension or tense muscles. It is the most commonly used by physical therapists to loosen muscles. One of the operation techniques. However, there is no literature to quantify the effect of myofascial mobilization. The purpose of this experiment is to evaluate whether MyotonPRO can quantify the changes in the muscle characteristics of the erector spinae in different postures and after myofascial relaxation, and to test the validity of the muscle tone tester.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 20 Years 至 65 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •age 20-65 healthy adult
排除标准
- •Radicular neurological signs
- •spinal deformity e.g.scoliosis, spondylolisthesis
- •infection or tumor
- •Rheumatologic conditions
- •Previous spinal surgery
- •History of hip or pelvic disorder that required treatment
- •male BMI> 27 and female BMI> 26
结局指标
主要结局
muscle stiffness of manual erector spinae myofascial realease
时间窗: 10 minutes
use MyotonPRO (Myoton AS, Tallinn, Estonia) to assess the muscle stiffness (N/m)
muscle elasticity of self-myofascial release technique
时间窗: 10 minutes
use MyotonPRO (Myoton AS, Tallinn, Estonia) to assess the muscle elasticity (ln(first wave peak/second wave peak))
muscle tone of self-myofascial release technique
时间窗: 10 minutes
use MyotonPRO (Myoton AS, Tallinn, Estonia) to assess the muscle tone (Hz)
muscle elasticity of manual erector spinae myofascial realease
时间窗: 10 minutes
use MyotonPRO (Myoton AS, Tallinn, Estonia) to assess the muscle elasticity (ln(first wave peak/second wave peak))
muscle stiffness of self-myofascial release technique
时间窗: 10 minutes
use MyotonPRO (Myoton AS, Tallinn, Estonia) to assess the muscle stiffness (N/m)
Muscle tone of manual erector spinae myofascial release
时间窗: 10 minutes
Use MyotonPRO (Myoton AS, Tallinn, Estonia) to assess the muscle tone (Hz)
次要结局
未报告次要终点