A Clinical Trial of a 20mm Transcatheter Bioprosthetic Valve for Patients With Aortic Stenosis

Edwards Lifesciences8 个研究点 分布在 1 个国家目标入组 17 人开始时间: 2011年6月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
17
试验地点
8
主要终点
NYHA Improvement and AVA >= 0.65 cm2

研究概览

简要总结

A single arm, prospective multicenter non-randomized pivotal clinical trial evaluating the 20mm Edwards SAPIEN XT™ transcatheter heart valve (model 9300TFX), NovaFlex™ transfemoral delivery system, and crimper accessories. The trial includes a premarket pivotal cohort to evaluate the system performance as well as a post market clinical follow-up phase involving long term follow-up of all patients to evaluate the safety of investigational devices up to 5 years.

详细描述

Purpose: To evaluate the safety and efficacy of THV-9300 (20mm) for patients who have severe symptomatic aortic stenosis attributed to calcification and degeneration of a valve leaflet and for whom undergoing a surgery safely would be difficult.

Enrollment: 15 patients (No.of patients needed: 12)

Follow-up: Subject data collection will include clinical information at baseline and during the index procedure. Subjects will undergo clinical follow-up at discharge, 30 days, 6 months and annually for 5 years.

Clinical sites:

1)Osaka University Hospital, 2)Kurashiki Central Hospital, 3)Sakakibara Heart Institute, 4) Kokura Memorial Hospital

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
19 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients who were judged difficult to safely undergo AVR
  • Severe senile degenerative aortic valve stenosis
  • NYHA Functional Class II or greater
  • Signed Informed Consent

排除标准

  • Aortic valve is congenital unicuspid or bicuspid
  • Annulus size between < 16 mm or > 19 mm
  • LVEF < 20 %

结局指标

主要结局

NYHA Improvement and AVA >= 0.65 cm2

时间窗: 1 year

Improvement of the aortic valve area (AVA) and New York Heart Association (NYHA) functional classification from baseline to 1 year after the procedure. NYHA functional classification of heart failure based on how much a patient is limited during physical activity. The rating ranges from I-IV, with the lowest (I) as no limitations and the highest (IV) unable to carry on any physical activity without discomfort. The AVA at 1 year \>= 0.65 cm2 indicates improvement. This outcome measure shows the percentage of patients that had an improvement in both NYHA Class and AVA. Note: One patient did not complete a 6-month echo.