Iowa Cochlear Implant Clinical Research Center Study on Robotic-Assisted Versus Manual Electrode Array Insertion

University of Iowa2 个研究点 分布在 1 个国家目标入组 100 人开始时间: 2025年6月30日最近更新:

试验速览

阶段
不适用
状态
招募中
入组人数
100
试验地点
2
主要终点
scalar translocation

研究概览

简要总结

Robotics-assisted electrode insertion overcomes many surgeon-related kinetic limitations such as insertion speed, tremor, drift, and lack of accurate force control. In human cadaveric cochleae, robotics-assisted electrode insertion causes less intracochlear trauma compared to manual insertion. Whether this technical advance results in functional benefits in CI patients remains unknown. To address this critical knowledge gap, the investigators will compare cochlear trauma assessed using CT scans, cochlear and AN function assessed using ECochG and/or the eCAP, and clinical outcomes quantified by postoperative residual acoustic hearing and speech perception scores between participants randomized to either manual or robotics-assisted electrode array insertion.

详细描述

Electrode insertion force is a critical determinant of the degree/amount of intracochlear trauma caused by CI surgery. It is affected by the speed of electrode array insertion, with higher insertion speeds leading to greater insertion forces. In addition, rapid electrode array insertions with higher forces are associated with translocation of electrode arrays from the scala tympani into the scala media or vestibuli which leads to lower performance and higher rates of loss of residual hearing. Furthermore, variability in insertion force during electrode insertion can cause dramatic increases in intracochlear fluid pressure which appears to be traumatic. The recent FDA-approved iotaSOFT™ insertion system is designed to address these issues by controlling the speed of implant insertion (0.1-1.0 mm/sec) with reduced insertion force and variability. Use of the iotaSOFT™ insertion system significantly reduces the maximum insertion force, variation in insertion force and intracochlear pressure changes over time, which leads to decreased intracochlear trauma compared with manual insertion in cadavers. In addition, this robotics-assisted insertion system can be used with ECochG monitoring systems, which enables response dynamics that can dramatically reduce electrode array stopping distances (1-2 µm of further electrode array advancement) compared to the kinetics of human manual insertion (~1 mm) once a change in intraoperative ECochG response is detected. Theoretically, robotics-assisted electrode array insertion should result in better preserved structural and functional integrity of the peripheral auditory system due to reduced intracochlear trauma. However, this theoretical possibility has not been tested in human CI users.

To address this knowledge gap, the investigators propose to determine the functional benefits of using robotics-assisted electrode insertion in reducing intracochlear trauma. This will be achieved by comparing trauma to the cochlea from electrode insertion based on postoperative CT scans, electrode impedance, the functional status of the cochlea and the AN, as well as preservation of acoustic hearing in participants randomized to have the electrode array inserted manually or with the iotaSOFT™ insertion system. The investigators hypothesize that robotics-assisted electrode insertion will better preserve peripheral structural and functional integrity by reducing intraoperative trauma. The investigators expect that participants with robotics-assisted electrode insertions will show smaller trauma scores based on CT scans, lower electrode impedance, better functional statuses of the AN, higher ENI indices, less hearing loss, and improved speech perception scores than participants with manual electrode insertions.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Basic Science
盲法
None

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Candidate for a cochlear implant according to CMS guidelines
  • Willingness to comply with all study requirements
  • Patent cochlea and normal cochlear anatomy, as confirmed by preoperative imaging
  • English speaking

排除标准

  • Medical or psychological conditions that contraindicate undergoing surgery
  • Ossification or any other cochlear anomaly that might prevent complete insertion of the electrode array.
  • Unrealistic expectations on the part of the candidate and/or candidate's family, regarding the possible benefits, risks, and limitations that are inherent to the surgical procedure(s) and prosthetic devices.

结局指标

主要结局

scalar translocation

时间窗: Postoperative standard of care CT (approximately at activation or 2 weeks)

Postoperative CT scan will be used to assess scalar translocation

Angular Insertion depth

时间窗: Postoperative standard of care CT (approximately at activation or 2 weeks)

Angle of the electrode array inside the cochlea, measured relative to the round window membrane.

次要结局

  • Impedance(initial activation and at 3 and 6 months post CI)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Bruce J Gantz

Chair Emeritus, Department of Otolaryngology--Head and Neck Surgery