临床试验/NCT01271543
NCT01271543已完成4 期

Comparing Hemodynamic Changes for Intubation With Shikani Intubating Stylet and Macintosh Laryngoscope

Milton S. Hershey Medical Center2 个研究点 分布在 1 个国家目标入组 60 人开始时间: 2011年2月最近更新:
适应症

试验速览

阶段
4 期
状态
已完成
入组人数
60
试验地点
2
主要终点
Heart Rate and Blood Pressure Double Product

研究概览

简要总结

Because of its simplicity of function and reliability, direct laryngoscopy it is routinely used for endotracheal intubation during general anesthesia. However, direct laryngoscopy is fraught with concerns for cardiovascular stimulation during induction of general anesthesia. This can be attributed to the placement of the laryngoscope blade into the vallecula and then applying force in an upward direction to expose the glottic opening. The average force necessary for visualization of the glottic opening is approximately 5.4kg. This can lead to significant pressor responses and tachycardia though stimuli to supraglottic region.

An alternative airway management device is the Shikani optical stylet (SOS). It is an effective, safe and reusable intubation device that has been shown to be effective in cases of difficult intubation. It consists of a fiberoptic bundle within a J - shaped malleable stainless steel sheath. At the proximal end of the sheath is an eyepiece with an attachment to a light source. An adjustable "tube stop" firmly affixes the endotracheal tube to the stylet, and has a port to be able to deliver oxygen. (4) The operator inserts the tip of the stylet with the loaded endotracheal tube into the patient's oropharynx and under direct visualization through the eyepiece, is able to visualize the vocal cords. Because the end of the stylet is at the end of the endotracheal tube, it can be directly visualized to be entering trachea past the vocal cords.

The investigators hypothesize that endotracheal intubation performed by the aid of SOS by minimizing oropharyngolaryngeal stimulation will result in fewer hemodynamic changes in patients with normal airways as compared with the MacIntosh laryngoscope.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single (Participant)

入排标准

年龄范围
18 Years 至 75 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • 18 - 75 years, ASA I and II, normotensive, Mallampati class: I and II, thyromental distance > than 6.5 cm, interincisor distance > than 3 cm, BMI < 35 Kg/m2

排除标准

  • Exclusion criteria: pregnant patients, known or expected difficult airway, gastroesophageal reflux, esophageal pathology, pulmonary pathology, cardiovascular pathology.

结局指标

主要结局

Heart Rate and Blood Pressure Double Product

时间窗: Noninvasive blood pressure and heart rate will be recorded preinduction, preintubation, and every min for the first 5 min after successful intubation.

The double product was measured. The double product is calculated by multiplying the heart rate with the systolic blood pressure. It is also known as the rate pressure product and it is used to measure hemodynamic response.The double product is calculated from the values obtained preinduction, during intubation and after intubation.(5 minutes after intubation)The double products from each time point are averaged to get one mean double product value.

次要结局

  • Time to Complete Laryngoscopy and Successful Intubation(Noninvasive blood pressure and heart rate will be recorded preinduction, preintubation, and every min for the first 5 min after successful intubation.)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Sonia Vaida

M.D, Vice Chair for Reasearch

Penn State University