Epilepsy Seizure Detection With Innovative Tripolar EEG (tEEG)
试验速览
- 阶段
- 不适用
- 状态
- 招募中
- 发起方
- 入组人数
- 90
- 试验地点
- 2
- 主要终点
- Technical and diagnostic accuracy
研究概览
简要总结
Concurrent electroencephalography (EEG) and new tripolar EEG (tEEG) will be recorded from adult and pediatric patients. In some patients stereo EEG (sEEG) will also be recorded concurrently.
详细描述
This study is a prospective observational study of the clinical utility (usability + accuracy) and safety of a novel EEG diagnostic device, the Tripolar Concentric Ring Electrode (TCE), that will be used to record the tripolar electroencephalogram (tEEG). The major objectives of the proposed studies will be to compare the recording qualities of the standard scalp EEG and intracranial stereo-EEG (sEEG), in preparation for obtaining FDA clearance for the TCRE and the tEEG technique. tEEG resolves the fundamental drawbacks of conventional EEG, providing significant improvement in signal fidelity, spatial resolution, and registering of higher frequency brain activities. In this project, a comparison of the safety, ease of use, and accuracy of the TCRE device to standard EEG and intracranial sEEG recordings in patients with epilepsy will be performed. An overview of the proposed studies are as follows:
Milestone 1: Simultaneous tEEG and EEG will be recorded in the outpatient clinical EEG lab. Per recording, tEEG and gold standard scalp EEG will be compared in 30-minute studies, examining a) usability (i.e., ease of application, time for electrode application, and subject ratings of comfort), b) EEG data quality, and c) accuracy of blinded analysis of common EEG patterns, including epileptiform activity.
Milestone 2: Data collected will be analyzed in Milestone 2, to assess the ability of tEEG to suppress commonly encountered EEG artifacts, by comparing blinded analysis of tEEG to the gold standard scalp EEG.
Milestone 3: Simultaneous tEEG and EEG will be collected in the inpatient epilepsy monitoring unit. It is anticipated that recordings will last 24-120 hours. From these data, a comparison of the sensitivity and accuracy of tEEG and scalp EEG for detection of seizures and high-frequency oscillations (HFOs) will be performed in long-term (24 hours to 120 hours) studies in subjects undergoing continuous video-EEG monitoring in the Epilepsy Monitoring Unit.
Milestone 4: A comparison of the accuracy of tEEG, to gold standard intracranial sEEG for seizure and high frequency oscillation (HFO) localization, will be performed in patients undergoing invasive diagnostic evaluation for epilepsy surgery.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 6 Years 至 —(Child, Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Pediatric (BCH): Age ≥ 6 years and < 18 years
- •Adult (BNI): Age ≥ 18 years
- •Able to provide written informed consent or have a legally authorized representative able to provide consent; pediatric patients to provide assent when appropriate
- •Scheduled for routine outpatient EEG for clinical diagnosis
- •Able to participate in a post-EEG telemedicine video visit
- •Clinical diagnosis of epilepsy with epileptiform discharges on prior routine EEG
- •Scheduled for inpatient video-EEG monitoring for clinical diagnosis
- •MRI of brain available for co-registration
- •Confirmed diagnosis of focal epilepsy by prior video-EEG monitoring interpreted by board-certified epileptologist or clinical neurophysiologist
- •Scheduled for inpatient video-EEG monitoring with intracranial stereo-EEG electrodes for epilepsy presurgical evaluation
- •MRI of brain available for co-registration
- •Exclusion criteria
- •Presence of a condition or abnormality that in the opinion of the Investigator would compromise the safety of the subject or the integrity of the data
- •Any clinical suspicion of prion disease
- •History of allergy or adverse reaction to EEG electrode paste or gel
- •Scalp lesions or infections
- •Severe intellectual disability or behavioral disorders with inability to cooperate with EEG application or recording
排除标准
- 未提供
结局指标
主要结局
Technical and diagnostic accuracy
时间窗: up to 10 days
1. Establish the technical accuracy of tEEG (ability to record waveforms accurately and reproducibly in clinical conditions in comparison to conventional EEG). 2. Establish the diagnostic accuracy of tEEG compared to conventional EEG (combination of improved artifact reduction, better interrater agreement for interictal epileptiform activity, and earlier identification of ictal patterns), as determined by blinded expert EEG readers.
次要结局
- Scalp integrity(up to 10 days)
- Recording of high frequency oscillations(up to 10 days)
- Seizure onset zone localization(up to 10 days)
- Tolerability of tripolar concentric ring electrode electroencephalography(up to 10 days)