跳至主要内容
临床试验/NCT04936191
NCT04936191已完成不适用

Dynamic Change of Coronary Artery Curvature After Adaptive Remodeling

National Taiwan University Hospital2 个研究点 分布在 1 个国家目标入组 48 人开始时间: 2022年11月18日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
48
试验地点
2
主要终点
The differences of vessel geometry

研究概览

简要总结

The novolimus-eluting DynamX bioadaptor system is composed of 71 µm cobalt-chromium sinusoidal rings connected to each other axially by three S-links Each ring contains three uncaging elements that are positioned at equal distance in low stress regions of struts oriented in a helical configuration along the length of the bioadaptor which remain intact after uncaging. The uncaging elements consist of three separable junctions per ring held together by a 6 µm polymer coating that is resorbed over six months, allowing uncaging of the vessel and adaptive remodeling. Previous study showed the DynamX biodaptor is safe and effective treating in de novo coronary lesion. It also increased of vessel and device area while maintain in the mean lumen area after one year follow-up. However, the unchanging effect of Dynamx bioadaptor on coronary geometry change remained unknown. The present randomized control study is designed to investigate the differences of dynamic coronary artery geometry changes evaluated by coronary computed tomography angiography after DynamX Bioadaptor and permanent metallic DES implantation.

详细描述

Coronary artery disease (CAD) is the most common type of heart disease and the leading cause of death worldwide. Percutaneous coronary intervention and coronary artery bypass graft are the guideline suggested treatment. Drug-eluting stents (DES) is the guideline suggested treatment options. Percutaneous coronary intervention with DES provides not just acute luminal gains, but also good long-term patency and clinical outcomes. However, in-stent neoatherosclerosis, very late stent thrombosis, and endothelial dysfunction remained important long-term issues. In addition, metallic stent encages the vessel segment, limits its remodeling and vasomotor function. The original vessel geometry, curvature, tortuosity, and wall shear stress, which are associated with plaque formation are also changed permanently by stent implantation. Although bioresorbable scaffolds attempted to address these issues by providing structural support to the vessel early on, followed by resorption, randomized trials showed that, prior to their resorption, they were less safe and effective than contemporary DES. Since that, the novel DES, DynamX Bioadaptor, is designed to improve these limitations.

The novel DES, DynamX Bioadaptor, is designed to restore normal pulsatility and adaptive remodeling in blood vessels after stent implantation. It is a cobalt-chromium stent with a biodegradable polymer coating that releases novolimus. Segments of the stent are held together by the polymer coating, which is designed to be fully absorbed in 6 months. After degradation of polymer, the stent struts unlink and uncage the stented segment. Pilot study demonstrated vessel uncaging and restoration of cyclic pulsatility 12 months after DynamX Bioadaptor implantation. Adaptive remodeling 12 months after DynamX Bioadaptor implantation will restore flexibility and natural geometry of the stented vessel segment. Thus, the dynamic beat-to-beat (cardiac cycle) changes of curvature and tortuosity will be more pronounced in the DynamX Bioadaptor group compared with that in the permanent metallic Elixir DESyne DES group. The DynamX Bioadaptor can potentially restore the vessel geometry and improve outcomes. The present randomized control study is designed to investigate the differences of dynamic coronary artery geometry changes after DynamX Bioadaptor and permanent metallic DES implantation, using coronary computed tomography angiography (CCTA) as an evaluation tool.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Double (Participant, Outcomes Assessor)

入排标准

年龄范围
20 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patient is ≥ 20 years old.
  • Written informed consent can be obtained.
  • The enrolled coronary vessel only has one target coronary lesion required stenting.
  • The target coronary lesion is 50 to 100% stenosis and stenting is required.
  • Coronary artery de novo lesion requiring implantation of a single drug eluting stent with length ≥ 32 mm.
  • Patients are able to tolerate dual antiplatelets for at least six months.

排除标准

  • Patient is unwilling to join this study.
  • Patients have end-stage renal disease under dialysis, chronic kidney disease (serum creatine > 1.5 mg/dL), symptomatic heart failure, active cancer, high bleeding risk, ST elevation myocardial infarction or hemodynamic unstable non-ST elevation myocardial infarction.
  • Coronary lesion with following features: heavily calcification, ostial lesion, lesions requiring post-stenting side branch dilatation and lesions required more than one stent to treat.
  • The left ventricular ejection fraction is ≤ 40%.
  • No scheduled operation within six months after the coronary stenting is allowed unless continuous dual antiplatelet use is acceptable.
  • Patients are unsuitable or unable to receive CCTA.
  • Pregnant women or women with breast feeding or suitable pregnant women without contraception during the study period.
  • Patient is currently participating another interventional trial.

结局指标

主要结局

The differences of vessel geometry

时间窗: 12 months ± 2 weeks

The differences of vessel geometry during systolic-diastolic phases, 12 months ± 2 weeks after DynamX Bioadaptor or Elixir DESyne DES implantation, measured by CCTA.

次要结局

  • New plaque formation related in-stent/in-segment restenosis(12 months ± 2 weeks)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验