跳至主要内容
临床试验/NCT03533517
NCT03533517进行中(未招募)不适用

An Early Feasibility Evaluation of the AccuCinch® Ventricular Restoration System in Patients With Heart Failure and Reduced Ejection Fraction (HFrEF) - The CorCinch-HFrEF Study

Ancora Heart, Inc.34 个研究点 分布在 1 个国家目标入组 22 人开始时间: 2018年8月23日最近更新:
适应症

试验速览

阶段
不适用
状态
进行中(未招募)
入组人数
22
试验地点
34
主要终点
Safety measured by device-related or procedure-related major adverse events (MAEs)

研究概览

简要总结

This is a non-randomized, prospective, multi-center Early Feasibility Study to evaluate the AccuCinch® Ventricular Restoration System in Patients with Heart Failure and Reduced Ejection Fraction (HFrEF).

详细描述

Device name changed from AccuCinch® Ventricular Repair System to AccuCinch® Ventricular Restoration System, FDA Approval Date 08Aug2020.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Device Feasibility
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Study patient is at least 18-years old
  • Ejection Fraction: ≥20 and ≤40%
  • LV end-diastolic diameter ≥55 mm
  • Symptom Status: NYHA III-IV (i.e., ambulatory)
  • Treatment and compliance with optimal guideline directed medical and device-based therapies for heart failure (unless contraindicated or intolerant) for at least 3 months and stable doses for 1 month with stable defined as no more than 100% increase or 50% decrease of total daily doses.
  • Patients with left bundle branch block pattern and QRS duration >150ms are required to have a CRT device for at least 3 months
  • Patients required to have an ICD are required to have ICD implant at least 1 month prior to enrollment
  • Able and willing to complete all qualifying diagnostic and functional tests and agrees to comply with study follow-up schedule

排除标准

  • Myocardial infarction or any percutaneous cardiovascular intervention, cardiovascular surgery, or carotid surgery within 3 months
  • Mitral regurgitation grade 3 (moderate-severe) or more
  • Prior surgical, transcatheter, or percutaneous mitral valve intervention
  • Untreated clinically significant coronary artery disease (CAD) requiring revascularization
  • Hemodynamic instability: Hypotension (systolic pressure <90 mmHg) or requirement for inotropic support or mechanical hemodynamic support
  • Any planned cardiac surgery or interventions within the next 6 months (including right heart procedures)
  • NYHA class IV (i.e., non-ambulatory)
  • Significant RV dysfunction (TAPSE < 14)
  • Severe tricuspid regurgitation
  • Hypertrophic cardiomyopathy, restrictive cardiomyopathy, constrictive pericarditis, or any other structural heart disease causing heart failure other than dilated cardiomyopathy of either ischemic or non-ischemic etiology
  • Anatomical pathology or constraints preventing appropriate access/implant of the AccuCinch® Ventricular Repair System (e.g., femoral arteries will not support a 20F system)
  • Renal insufficiency (i.e., eGFR of <30ml/min/1.73m2; Stage 4 or 5 CKD)
  • Moderate or severe aortic valve stenosis or regurgitation or aortic valve prosthesis
  • Fluoroscopic or echocardiographic evidence of severe aortic arch calcification, mobile aortic atheroma, intracardiac mass, thrombus or vegetation
  • Active bacterial endocarditis
  • History of any stroke within the prior 3 months or Modified Rankin Scale ≥ 4 disability from any prior stroke
  • Subjects in whom anticoagulation or antiplatelet therapy is contraindicated
  • Known allergy to nitinol, polyester, or polyethylene
  • Any prior true anaphylactic reaction to contrast agents; defined as known anaphylactoid or other non-anaphylactic allergic reactions to contrast agents that cannot be adequately pre-medicated prior to the index procedure.
  • Life expectancy < 1 year due to non-cardiac conditions
  • Currently participating in another interventional investigational study
  • Implant or revision of any rhythm management device (CRT or CRT-D) prior 3 months or implantable cardioverter defibrillator within the prior 1 month
  • Subjects on high dose steroids or immunosuppressant therapy
  • Female subjects who are pregnant, of child bearing potential without a documented birth control method, or lactating

结局指标

主要结局

Safety measured by device-related or procedure-related major adverse events (MAEs)

时间窗: 30-day

Device-related or procedure-related major adverse events (MAEs)

次要结局

未报告次要终点

研究者

申办方类型
Industry
责任方
Sponsor

研究点 (34)