跳至主要内容
临床试验/NCT04437407
NCT04437407终止不适用

UniSA BackOff! Study: A Randomized, Controlled, Five-way, Cross-over Trial to Evaluate the Effect of a Positional Therapy Device on Maternal Sleeping Position in the Third Trimester of Pregnancy

Shiphrah Biomedical Inc.2 个研究点 分布在 1 个国家目标入组 6 人开始时间: 2020年2月1日最近更新:
适应症

试验速览

阶段
不适用
状态
终止
入组人数
6
试验地点
2
主要终点
Specificity of Ajuvia for prone position

研究概览

简要总结

Stillbirth (SB) is a devastating complication of pregnancy and contributes to over 2 million deaths globally every year. Over 20 million infants are born every year with low birth weight (LBW), which is associated with a twenty times increased risk of death in the first year of life and high rates of short- and long-term illnesses. Sleeping on one's back during pregnancy has recently emerged as a potential risk factor for LBW and SB in the medical literature. In high-income countries, SB rates have mostly remained the same in the past two decades and targeting modifiable risk factors could help reduce the number of SB and LBW in the population.

When a pregnant woman sleeps on her back, her body position compresses underlying blood vessels and reduces blood flow to the developing baby. This body position could cause unpleasant symptoms for the mother and result in LBW or SB of her baby. Lying on her side or with a slight lateral tilt helps relieve this compression. One way to keep people off their back while sleeping is by using positional therapy (PT). It is a simple, safe, inexpensive and effective intervention for preventing people who snore or people who's breathing pauses during sleep from sleeping on their back. Reducing the amount of time pregnant women sleep on their back could help reduce SB and LBW rates. The investigators developed a PT device (PrenaBelt) and tested it in three clinical trials, which demonstrated that it significantly decreases the number of time women spend sleeping on their back. Using feedback from our previous research, the investigators developed five additional devices that will be tested in this study.

The purpose of this study is to evaluate the new PrenaBelt (PB2) prototypes' ability to reduce the amount of time pregnant women sleep on their backs in the third trimester of pregnancy, validate the Ajuvia Sleep Monitor, and collect feedback on the devices.

Demonstrating that the sleeping position of pregnant women can be modified through the use of a simple, inexpensive PT intervention may be one of the keys to achieving significant reductions in LBW and late SB rates in Australia and worldwide.

详细描述

The ability of the PB2 prototypes to reduce the amount of time pregnant women spend sleeping on their backs at night in the home setting in the third trimester of pregnancy will be evaluated via a consecutive, six-night, in-home, controlled, cross-over sleep study in third trimester pregnant women where the Ajuvia Sleep Monitor is validated against infrared video on the first night.

Six nights: the first night is a control night with infrared video recording where only the Ajuvia is worn in passive mode to collect data on the participant's body position and is followed by five nights with the five different prototypes.

Randomization: The order in which the different devices will be worn on the second night through fourth night, inclusive, will be determined by simple randomization. This will minimize the potential impact of changes to sleep across the nights resulting from familiarization with the equipment as the sleep tests proceed through the five non-control nights, which could bias the results. For logistical reasons, the sixth night is non-randomized and will include the Ajuvia in 'active' mode Cross-over: After the first night, on each of the subsequent four nights, the participants will "cross over" to a different PB2 device (depending on their randomization order) and "cross over" to the Ajuvia in 'active' mode on the sixth night to allow each participant to act as her own control for comparison of treatment effect on outcomes.

In home: conducting this study in the home setting will allow for a more accurate representation of sleep patterns as the participants will be in the comfort of their own bed.

Sleep test: The maternal pelvis position will be recorded while the participants are sleeping using the Ajuvia device. Going to bed- and wake-times, as well as experience with each device will be recorded daily in a sleep diary.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Prevention
盲法
Double (Investigator, Outcomes Assessor)

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
Female
接受健康志愿者

入选标准

  • ≥18 years old
  • low-risk singleton pregnancy
  • in the last trimester of pregnancy (at least 28 weeks + 0 days but not more than 36 weeks + 0 days of gestation)
  • access to and ability to use iPhone (for downloading and using Ajuvia app)
  • residing in the Greater Adelaide Area.

排除标准

  • musculoskeletal disorder that prevents sleeping supine or on a certain side (e.g., arthritic shoulder)
  • non-English speaking and reading

结局指标

主要结局

Specificity of Ajuvia for prone position

时间窗: 1 night (approximately 8 hours)

The specificity(%) of the Ajuvia in determining the pelvic prone position during night sleep against the gold-standard of position as determined by review of infrared video will be calculated using a two-by-two contingency table.

Sensitivity of Ajuvia for left tilt position

时间窗: 1 night (approximately 8 hours)

The sensitivity(%) of the Ajuvia in determining the left pelvic tilt position during night sleep against the gold-standard of position as determined by review of infrared video will be calculated using a two-by-two contingency table.

Specificity of Ajuvia for left tilt position

时间窗: 1 night (approximately 8 hours)

The specificity(%) of the Ajuvia in determining the left pelvic tilt position during night sleep against the gold-standard of position as determined by review of infrared video will be calculated using a two-by-two contingency table.

Sensitivity of Ajuvia for supine position

时间窗: 1 night (approximately 8 hours)

The sensitivity(%) of the Ajuvia in determining the pelvic supine position during night sleep against the gold-standard of position as determined by review of infrared video will be calculated using a two-by-two contingency table.

Sensitivity of Ajuvia for left lateral position

时间窗: 1 night (approximately 8 hours)

The sensitivity(%) of the Ajuvia in determining the left lateral pelvic position during night sleep against the gold-standard of position as determined by review of infrared video will be calculated using a two-by-two contingency table.

Specificity of Ajuvia for left lateral position

时间窗: 1 night (approximately 8 hours)

The specificity(%) of the Ajuvia in determining the left lateral pelvic position during night sleep against the gold-standard of position as determined by review of infrared video will be calculated using a two-by-two contingency table.

Sensitivity of Ajuvia for right lateral position

时间窗: 1 night (approximately 8 hours)

The sensitivity(%) of the Ajuvia in determining the right lateral pelvic position during night sleep against the gold-standard of position as determined by review of infrared video will be calculated using a two-by-two contingency table.

Specificity of Ajuvia for right lateral position

时间窗: 1 night (approximately 8 hours)

The specificity(%) of the Ajuvia in determining the right lateral pelvic position during night sleep against the gold-standard of position as determined by review of infrared video will be calculated using a two-by-two contingency table.

Specificity of Ajuvia for supine position

时间窗: 1 night (approximately 8 hours)

The specificity(%) of the Ajuvia in determining the pelvic supine position during night sleep against the gold-standard of position as determined by review of infrared video will be calculated using a two-by-two contingency table.

Sensitivity of Ajuvia for prone position

时间窗: 1 night (approximately 8 hours)

The sensitivity(%) of the Ajuvia in determining the pelvic prone position during night sleep against the gold-standard of position as determined by review of infrared video will be calculated using a two-by-two contingency table.

Sensitivity of Ajuvia for right tilt position

时间窗: 1 night (approximately 8 hours)

The sensitivity(%) of the Ajuvia in determining the right pelvic tilt position during night sleep against the gold-standard of position as determined by review of infrared video will be calculated using a two-by-two contingency table.

Specificity of Ajuvia for right tilt position

时间窗: 1 night (approximately 8 hours)

The specificity(%) of the Ajuvia in determining the right pelvic tilt position during night sleep against the gold-standard of position as determined by review of infrared video will be calculated using a two-by-two contingency table.

Supine Sleep Time - Control

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the supine position with Ajuvia in passive mode

Supine Sleep Time - PB2-1

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the supine position with PB2-1 and Ajuvia in passive mode

Supine Sleep Time - PB2-2

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the supine position with PB2-2 and Ajuvia in passive mode

Supine Sleep Time - PB2-3

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the supine position with PB2-3 and Ajuvia in passive mode

Supine Sleep Time - PB2-5

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the supine position with PB2-5 and Ajuvia in active mode

Supine Sleep Time - PB2-4

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the supine position with PB2-4 and Ajuvia in passive mode

Prone Sleep Time - Control

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the prone position with Ajuvia in passive mode

Prone Sleep Time - PB2-4

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the prone position with PB2-4 and Ajuvia in passive mode

Prone Sleep Time - PB2-1

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the prone position with PB2-1 and Ajuvia in passive mode

Left-tilt Sleep Time - PB2-1

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the left pelvic tilt position with PB2-1 and Ajuvia in passive mode

Left-tilt Sleep Time - PB2-2

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the left pelvic tilt position with PB2-2 and Ajuvia in passive mode

Left-tilt Sleep Time - PB2-3

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the left pelvic tilt position with PB2-3 and Ajuvia in passive mode

Prone Sleep Time - PB2-5

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the prone position with PB2-5 and Ajuvia in active mode

Left-tilt Sleep Time - Control

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the left pelvic tilt position with Ajuvia in passive mode

Prone Sleep Time - PB2-2

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the prone position with PB2-2 and Ajuvia in passive mode

Prone Sleep Time - PB2-3

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the prone position with PB2-3 and Ajuvia in passive mode

Left-tilt Sleep Time - PB2-4

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the left pelvic tilt position with PB2-4 and Ajuvia in passive mode

Left-lateral Sleep Time - Control

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the left lateral position with Ajuvia in passive mode

Right-lateral Sleep Time - Control

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the right lateral position with Ajuvia in passive mode

Right-lateral Sleep Time - PB2-1

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the right lateral position with PB2-1 and Ajuvia in passive mode

Left-tilt Sleep Time - PB2-5

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the left pelvic tilt position with PB2-5 and Ajuvia in active mode

Left-lateral Sleep Time - PB2-4

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the left lateral position with PB2-4 and Ajuvia in passive mode

Right-tilt Sleep Time - PB2-1

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the right pelvic tilt position with PB2-1 and Ajuvia in passive mode

Left-lateral Sleep Time - PB2-2

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the left lateral position with PB2-2 and Ajuvia in passive mode

Left-lateral Sleep Time - PB2-3

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the left lateral position with PB2-3 and Ajuvia in passive mode

Right-tilt Sleep Time - Control

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the right pelvic tilt position with Ajuvia in passive mode

Left-lateral Sleep Time - PB2-5

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the left-lateral position with PB2-5 and Ajuvia in active mode

Right-tilt Sleep Time - PB2-2

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the right pelvic tilt position with PB2-2 and Ajuvia in passive mode

Left-lateral Sleep Time - PB2-1

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the left lateral position with PB2-1 and Ajuvia in passive mode

Right-tilt Sleep Time - PB2-3

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the right pelvic tilt position with PB2-3 and Ajuvia in passive mode

Right-tilt Sleep Time - PB2-4

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the right pelvic tilt position with PB2-4 and Ajuvia in passive mode

Right-tilt Sleep Time - PB2-5

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the right pelvic tilt position with PB2-5 and Ajuvia in active mode

Right-lateral Sleep Time - PB2-4

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the right lateral position with PB2-4 and Ajuvia in passive mode

Right-lateral Sleep Time - PB2-2

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the right lateral position with PB2-2 and Ajuvia in passive mode

Right-lateral Sleep Time - PB2-3

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the right lateral position with PB2-3 and Ajuvia in passive mode

Right-lateral Sleep Time - PB2-5

时间窗: 1 night (approximately 8 hours)

The time (in minutes) spent sleeping in the right lateral position with PB2-5 and Ajuvia in active mode

次要结局

未报告次要终点

研究者

申办方类型
Industry
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验