跳至主要内容
临床试验/NCT07682311
NCT07682311招募中不适用

Automated Daytime Adaptive Deep Brain Stimulation Parameter Optimization in Patients Implanted With Percept Neurostimulator

University of California, San Francisco1 个研究点 分布在 1 个国家目标入组 40 人开始时间: 2026年6月4日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
招募中
入组人数
40
试验地点
1
主要终点
Change in number of bothersome movement symptoms on data-driven adaptive deep brain stimulation compared to open-loop deep brain stimulation

研究概览

简要总结

Parkinson's disease (PD) affects ~1% of people over 60 years old, is highly disabling and represents a large economic burden. While dopaminergic medications effectively treat motor symptoms early in the disease, most patients develop complications, including motor fluctuations and dyskinesias, which can be partially managed by deep brain stimulation (DBS). This surgical therapy consists of delivering continuous electrical stimulation through electrodes permanently implanted in basal ganglia nuclei, with a pulse generator and battery unit implanted in the chest. However, conventional DBS therapy is delivered with constant stimulation parameters, referred to as constant deep brain stimulation (cDBS), that are unresponsive to patient activities or to variations in the severity of symptoms during daily life. This leaves many patients under- or over-stimulated during parts of the day.

To address the shortcomings of cDBS, adaptive DBS (aDBS) uses real-time detection of neural signals to automatically adjust stimulation amplitude or other parameters in response to patients' dynamic clinical needs. aDBS was approved by the U.S. Food and Drugs Administration (FDA) for clinical treatment of PD in the Percept PC and RC (Medtronic) device in February 2025.

Fully leveraging this therapy in the real world is limited by technical challenges, in particular the fact that: while the investigators developed a consistent pipeline for implementing aDBS, there were several critical control parameters that strongly influenced algorithm performance and required prolonged trial-and-error based testing, to achieve successful control. In this new study, the investigators seek to significantly extend this work and address the major barriers to widespread, easy adoption of aDBS by groups without specialized knowledge of neurophysiology or feedback control. Here the investigators aim to test an automated, data-driven pipeline for the recommendation of the adaptive control parameters.

详细描述

Parkinson's disease (PD) affects ~1% of people over 60 years old, is highly disabling and represents a large economic burden. While dopaminergic medications effectively treat motor symptoms early in the disease, most patients develop complications, including motor fluctuations and dyskinesias, which can be partially managed by deep brain stimulation (DBS). This surgical therapy consists of delivering continuous electrical stimulation through electrodes permanently implanted in basal ganglia nuclei, with a pulse generator and battery unit implanted in the chest. DBS devices have been implanted in ~200,000 PD patients worldwide and most PD patients will become surgical candidates during their disease. Further, DBS is an approved treatment for essential tremor and isolated dystonia, and a potential treatment for other brain disorders, including major depression. Thus, the potential impact of improvements in DBS systems is high. However, conventional DBS therapy is delivered with constant stimulation parameters, referred to as constant deep brain stimulation (cDBS), that are unresponsive to patient activities or to variations in the severity of symptoms during daily life. This leaves many patients under- or over-stimulated during parts of the day. To address the shortcomings of cDBS, adaptive DBS (aDBS) uses real-time detection of neural signals to automatically adjust stimulation amplitude or other parameters in response to patients' dynamic clinical needs. aDBS was approved by the U.S. Food and Drugs Administration (FDA) for clinical treatment of PD in the Percept PC and RC (Medtronic) device in February 2025.

The original studies of aDBS in PD were performed peri-operatively, with externalized brain leads attached to a large equipment rack. Fully implantable bidirectional neural interfaces, which can sense neural activity during stimulation and have circuitry to implement feedback control, have recently been available for investigational use only in the US. Medtronic Percept PC is a commercial neurostimulator that has chronic brain sensing enabled as a standard feature. Its adaptive DBS capability is now commercially available following a pivotal trial that demonstrated safety. A rechargeable version of Percept (Percept RC) was released in January 2024. Until recently, most aDBS studies using these devices have been performed in clinic, for short durations only, often in a "distributed mode" in which neural signals are routed through an external computer. While useful for therapy development, distributed mode aDBS would be cumbersome to use in patients going about their normal daily lives, given the need for close proximity to an external computer. As a result of our group's recently completed NIH funded study, "Closed loop deep brain stimulation in Parkinson's disease", the investigators achieved the first demonstration that chronic personalized embedded aDBS improves parkinsonian motor signs more than fully optimized cDBS. The investigators have implanted 12 subjects with bilateral subthalamic depth leads, for stimulation and sensing, and chronic bilateral subdural cortical paddle-type leads, for sensing only. These were attached to an investigational pulse generator, enabled for sensing and aDBS, Summit RC+S (Medtronic). Patients were first clinically optimized in cDBS by a movement disorders neurologist for up to 1 year. A subset of patients, following clinical optimization, had bothersome residual motor signs (bradykinesia, dyskinesia, or dystonia), despite optimal cDBS. The investigators developed a method of aDBS based on the detection of individualized cortical or subcortical oscillatory activities that served as markers of hyperkinetic or hypokinetic states. The investigators implemented a control policy that automatically adjusted stimulation levels between predefined upper and lower limits, smoothing out residual motor fluctuations. In a first randomized, blinded study design comparing personalized aDBS to clinically optimized cDBS, aDBS significantly reduced the patient's most bothersome residual motor fluctuations, assessed both in blinded daily self-assessments, and objectively by wearable monitors, and improved quality of life. One other formal clinical trial of chronic adaptive DBS was recently completed (the Medtronic ADAPT study in North America and Europe, utilizing the Percept PC), and another one is recruiting (a study sponsored by Newronica, Inc., in Europe only, utilizing the AlphaDBS device). Both trials aim to adjust stimulation amplitude using basal ganglia beta band activity. In results of these unblinded, uncontrolled, studies, aDBS is only shown to be approximately equivalent, rather than significantly superior to cDBS.

Fully leveraging this therapy in the real world is limited by technical challenges, in particular the fact that: while the investigators developed a consistent pipeline for implementing aDBS, there were several critical control parameters that strongly influenced algorithm performance and required prolonged trial-and-error based testing, to achieve successful control. Our initial study demonstrated that fully embedded, chronic aDBS improved neurostimulation therapy compared to highly optimized standard cDBS. In this new study, the investigators seek to significantly extend this work and address the major barriers to widespread, easy adoption of aDBS by groups without specialized knowledge of neurophysiology or feedback control. To address the barrier presented by the large new parameter space (8 additional parameters for finetuned control) created by the greatly expanded suite of aDBS control settings and the need for periodic adjustment, here the investigators aim to test an automated, data-driven pipeline for the recommendation of the adaptive control parameters.

Potential risks associated with the study include temporary worsening of symptoms associated with medication withholding and with adjusting stimulation, which might induce periods of over- and under-stimulation that could lead to temporary worsening of motor and non-motor symptoms that are usually not severe, and in rare cases could lead to suicidal ideation and severe non-motor symptoms such as temporary confusion. Other risks include increased battery drain due to neural data recording and stimulation adapting, and skin irritation due to using wearable monitors to track severity of PD symptoms. Benefits from the study include improved clinical management of PD symptoms, close follow-up with and improved understanding of PD conditions in the enrolled patients. The investigators will mitigate the risks by performing offline verification of all pipeline-suggested aDBS settings before their application and ensuring that stimulation amplitudes stay within the safe amplitude limits set by the clinician. Note that there is no direct or automated connection between the analysis pipeline and the Percept device. All parameter suggestions are reviewed by a clinical researcher and manually programmed if deemed appropriate. In addition, patients will always have the option to revert to their baseline DBS settings.

This study will consist of a Phase 0, randomized, blinded, counterbalanced, within-subject study design, evaluating the performance of adaptive DBS based on automatically derived parameters compared to standard cDBS, assessed according to objective and subjective measures.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Treatment
盲法
Single (Participant)

入排标准

年龄范围
25 Years 至 75 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Diagnosis of idiopathic PD.
  • Patient has undergone surgical intervention with deep brain stimulation (Percept device) for their disorder at least 2 months prior to recruitment.
  • Absence of significant cognitive impairment (score of 24 or greater on the Montreal Cognitive Assessment (MoCA)).
  • Signed informed consent.
  • Ability to comply with study follow-up visits for brain recording, testing of adaptive stimulation, and clinical assessment.
  • Patient has been on cDBS for at least two months and still experiences significant residual motor fluctuation while on cDBS. Consequently, patient is undergoing aDBS treatment currently or was recommended aDBS as part of clinical care to manage their residual motor fluctuation.
  • Has available cDBS Timeline LFP and stimulation data lasting at least 1 day.
  • To be enrolled in the clinical trial phase of the study, patient will need to consent to reverting back to their baseline cDBS settings for all required cDBS testings.

排除标准

  • Patient meets criteria for a psychogenic movement disorder.
  • Significant untreated depression (BDI-II score >20). History of suicidal attempt or active suicidal ideation (Yes to #2-5 on C-SSRS).
  • Any personality or mood symptoms that study personnel believe will interfere with study requirements.

研究组 & 干预措施

Data-driven adaptive DBS programming

Experimental

Patients receive adaptive deep brain stimulation delivered through the Medtronic Percept PC/RC device, programmed with control parameters (sensing channel, detection thresholds, ramp rates, stimulation amplitude limits) recommended by the data-driven optimization pipeline and reviewed by a clinical researcher before programming. Stimulation amplitude is automatically adjusted between predefined upper and lower limits in response to sensed beta-band neural activity. Applied in counterbalanced 1-7 day blocks during awake hours in Session 6. These blocks will be randomized and counterbalanced for 40-60 days in patients' homes. Patients will be in cDBS mode overnight and will perform a blinded switch to either cDBS or aDBS upon waking in the morning.

干预措施: Medtronic Percept Deep Brain Stimulation (adaptive DBS) (Device)

Open-loop continuous deep brain stimulation

Active Comparator

Participants with Parkinson's disease implanted with Percept and receiving open-loop deep brain stimulation.

干预措施: Medtronic Percept Deep Brain Stimulation (adaptive DBS) (Device)

Open-loop continuous deep brain stimulation

Active Comparator

Participants with Parkinson's disease implanted with Percept and receiving open-loop deep brain stimulation.

干预措施: Medtronic Percept Deep Brain Stimulation (cDBS) (Device)

Data-driven adaptive DBS programming

Experimental

Patients receive adaptive deep brain stimulation delivered through the Medtronic Percept PC/RC device, programmed with control parameters (sensing channel, detection thresholds, ramp rates, stimulation amplitude limits) recommended by the data-driven optimization pipeline and reviewed by a clinical researcher before programming. Stimulation amplitude is automatically adjusted between predefined upper and lower limits in response to sensed beta-band neural activity. Applied in counterbalanced 1-7 day blocks during awake hours in Session 6. These blocks will be randomized and counterbalanced for 40-60 days in patients' homes. Patients will be in cDBS mode overnight and will perform a blinded switch to either cDBS or aDBS upon waking in the morning.

干预措施: Medtronic Percept Deep Brain Stimulation (cDBS) (Device)

结局指标

主要结局

Change in number of bothersome movement symptoms on data-driven adaptive deep brain stimulation compared to open-loop deep brain stimulation

时间窗: Through study completion, an average of 1 year.

Troublesome movement symptoms will be detected using validated wearable devices along with participant self-reporting.

次要结局

  • Changes in Quality of Life(Through study completion, an average of 1 year.)
  • Change in Total Electrical Energy Delivered (TEED)(Through study completion, an average of 1 year.)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Simon J. Little, MBBS, PhD

Assistant Professor, Clinical Neurology

University of California, San Francisco

研究点 (1)

Loading locations...

相似试验