A Prospective, Multicenter, Self-controlled Clinical Trial to Validate Optical Ultrasonic Flow Ratio (OUFR) Based on Intravascular Imaging

Harbin Medical University5 个研究点 分布在 1 个国家目标入组 114 人开始时间: 2024年11月10日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
114
试验地点
5
主要终点
Patient-level sensitivity and specificity

研究概览

简要总结

The objective of is study is to validate a novel computational Fractional Flow Reserve (FFR) index method, termed Optical Ultrasonic Flow Ratio (OUFR), based on intravascular imaging including intravascular optical coherence tomography (OCT) and intravascular ultrasound (IVUS), using wire-based FFR as the gold standard. This is a prospective, multi-center, self-controlled clinical trial involving at least four medical centers and recruiting at least 114 subjects based on statistical power analysis.

Participants undoing anticipated percutaneous coronary intervention will be performed:

  1. Wire-based FFR measurement
  2. Intravascular imaging, including IVUS and integrated OCT-IVUS using a single catheter.

The primary endpoint is to assess patient-level sensitivity, specificity of OUFR computed based on OCT; (2) OUFR based on IVUS, and OUFR based on both OCT and IVUS, using wire-based FFR measurement as the gold standard.

详细描述

The objective of this study is to verify a novel computational Fractional Flow Reserve (FFR) index method, termed Optical Ultrasonic Flow Ratio (OUFR), based on intravascular imaging including intravascular optical coherence tomography (OCT) and intravascular ultrasound (IVUS). This is a prospective, multi-center, self-controlled clinical trial involving at least four medical centers to verify OUFR using wire-based FFR measurement as the gold standard.

Subjects: At least 114 subjects will be recruited based on statistical power analysis.

The primary inclusion criteria include: (1) At least 18 years old; (2) Anticipate to be performed percutaneous coronary intervention (PCI); (3) Can sustain FFR measurement, IVUS and OCT imaging; (4) Understand the objective of this study, and sign informed consent form voluntarily. (5) The pullback of intravascular imaging covers the FFR measurement site and the entire stenotic lesion, and the OCT and IVUS images are of sufficient quality for OUFR analysis.

Specific exclusion criteria include: (1) Women with pregnancy or anticipate to be pregnant within 6 months; (2) Participated in other clinical studies within 3 months; (3) Had acute coronary syndromes within 30 days; (4) Heart failure (NYHA III or NYHA IV, or left ventricular ejection fraction<30%); (5) Abnormal levels of cTnI or cTnT within 72 hours of the procedure; (6) Had coronary artery bypass grafting surgery; (7) Diagnosed as bacteremia or septicemia; (8) Diagnosed as coronary artery spasm; (9) Clinically significant abnormal coagulation function; (10) Clinically significant abnormal liver or kidney function; (11) Clinically significant hemodynamic disorders or coma; (12) Allergic to contrast or have other potential risks due to allergy; (13) Presence of clinical unstable conditions, including acute chest pain, cardiogenic shock, unstable blood pressure (e.g. systolic pressure < 90mmHg), severe congestive heart failure or acute pulmonary edema; (14) Presence of other medical conditions not suitable for participating in this clinical study, such as complex congenital heart disease, myocardial bridge, long QT syndrome (LQTS), severe asthma, severe chronic obstructive pulmonary disease (COPD), or COPD with a dependency on bronchodilator, or with other severe infection or acute diseases; (15) Reference vessel diameter outside the range of 2.0-4.0mm by angiography, and diameter stenosis outside the range of 30%-90%; (16) Lesions associated with left main or coronary ostium, target vessel with severe tortuosity or calcified lesions, coronary total occlusion, diffuse lesions; (17) Target vessel with thrombus or dissection confirmed by angiography; (18) Target vessel with previous stenting; (19) Target vessel with the minimum lumen diameter < 1.1mm; (20) TIMI flow grade≤2; (21) Balloon predilatation before FFR wire measurement or intravascular imaging; (22) FFR wire or intravascular imaging catheter cannot pass the stenotic lesion; (23) Unable to observe maximal hyperemia during FFR measurement or failure to obtain FFR data; (24) Intravascular imaging failure due to the damage of imaging catheters or insufficient blood clearance, or operational factors; (25) Presence of vasospasm or injury during imaging; (24) Other reasons identified by investigators that preclude the subjects from participating in the study.

Main intervantional procedure: (1) For subjects meeting all the inclusion criteria, obtain the informed consent; (2) Apply exclusion criteria based on medical history and conditions; (3) Perform coronary angiography; (4) Perform FFR measurement using the pressure wire from Abbott (IL, USA); (5) Perform intravascular imaging with the C1-1 catheter from Panovision (Beijing, China) to obtain IVUS and integrated OCT-IVUS pullback images; (6) Apply exclusion criteria based on angiography, FFR and intravascular imaging, if necessary; (7) Collect data from all centers and send the data to an independent Corelab from the lead institution for OUFR computation and statistical analysis.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • At least 18 years old
  • Anticipate to be performed percutaneous coronary intervention (PCI)
  • Can sustain FFR measurement, IVUS and OCT imaging
  • Understand the objective of this study, and sign informed consent form voluntarily
  • The pullback of intravascular imaging covers the FFR measurement site and the entire stenotic lesion, and the OCT and IVUS images are of sufficient quality for OUFR analysis

排除标准

  • Women with pregnancy or anticipate to be pregnant within 6 months
  • Participated in other clinical studies within 3 months
  • Had acute coronary syndromes within 30 days
  • Heart failure (NYHA III or NYHA IV, or left ventricular ejection fraction<30%)
  • Abnormal levels of cTnI or cTnT within 72 hours of the procedure
  • Had coronary artery bypass grafting surgery
  • Diagnosed as bacteremia or septicemia
  • Diagnosed as coronary artery spasm
  • Clinically significant abnormal coagulation function
  • Clinically significant abnormal liver or kidney function
  • Clinically significant hemodynamic disorders or coma
  • Allergic to contrast or have other potential risks due to allergy
  • Presence of clinical unstable conditions, including acute chest pain, cardiogenic shock, unstable blood pressure (e.g. systolic pressure < 90mmHg), severe congestive heart failure or acute pulmonary edema
  • Presence of other medical conditions not suitable for participating in this clinical study, such as complex congenital heart disease, myocardial bridge, long QT syndrome (LQTS), severe asthma, severe chronic obstructive pulmonary disease (COPD), or COPD with a dependency on bronchodilator, or with other severe infection or acute diseases
  • Reference vessel diameter outside the range of 2.0-4.0mm by angiography, and diameter stenosis outside the range of 30%-90%
  • Lesions associated with left main or coronary ostium, target vessel with severe tortuosity or calcified lesions, coronary total occlusion, diffuse lesions
  • Target vessel with thrombus or dissection confirmed by angiography
  • Target vessel with previous stenting
  • Target vessel with the minimum lumen diameter < 1.1mm
  • TIMI flow grade≤2
  • Balloon predilatation before FFR wire measurement or intravascular imaging
  • FFR wire or intravascular imaging catheter cannot pass the stenotic lesion
  • Unable to observe maximal hyperemia during FFR measurement or failure to obtain FFR data
  • Intravascular imaging failure due to the damage of imaging catheters or insufficient blood clearance, or operational factors
  • Presence of vasospasm or injury during imaging
  • Other reasons identified by investigators that preclude the subjects from participating in the study

结局指标

主要结局

Patient-level sensitivity and specificity

时间窗: "From enrollment to the end of data analysis, up to 12 months

With wire-based FFR measurement as the gold standard, using FFR=0.8 as the diagnostic threshold (FFR≤0.8: positive, FFR\>0.8: negative), evaluate patient-level sensitivity, specificity of (1) OUFR computed based on OCT (OUFRo); (2) OUFR based on IVUS (OUFRi); and (3) OUFR based on both OCT and IVUS (OUFRoi).

次要结局

  • Vessel-level sensitivity and specificity of OUFR("From enrollment to the end of data analysis, up to 12 months)
  • Patient-level accuracy of OUFR(From enrollment to the end of data analysis, up to 12 months)
  • Patient and vessel level positive predictive value (PPV), negative predictive value (NPV) and area under the ROC curve (AUC)(From enrollment to the end of data analysis, up to 12 months)

研究者

发起方
Harbin Medical University
申办方类型
Other
责任方
Principal Investigator
主要研究者

Yu Bo

Director, cardiology department, the 2nd Affiliated Hospital of Harbin Medical University

Harbin Medical University