Endoscopic Ultrasound Elastography (Strain Ratio) and Fractal-based Quantitative Analysis for the Mediastinal and Abdominal Lymphadenopathies

Istituto Clinico Humanitas1 个研究点 分布在 1 个国家目标入组 101 人开始时间: 2019年9月27日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
101
试验地点
1
主要终点
Accuracy of quantitative EUS-E (strain ratio)

研究概览

简要总结

Endoscopic ultrasound (EUS) and EUS-guided tissue acquisition (EUS-TA) are minimally invasive techniques to establish the benign or malignant nature of lymph nodes (LNs) with a very high accuracy. In particular, for mediastinal LNs, a meta-analysis underlined that EUS features alone are not enough to reach a good sensitivity and specificity, while EUS-TA showed a slightly high sensitivity (88% vs. 85%) and a significantly high specificity (96% vs. 85%) for diagnosing the cause of LN enlargement. Considering all sites, according to the meta-analysis of Xu and colleagues, the assessment of LNs by EUS-elastography is a useful tool in differentiating benign and malignant LNs, with a sensitivity of 88% and a specificity of 85%.

For lymphadenopathy of unknown origin, ESGE recommends performing EUS-TA (or alternatively endobronchial ultrasound [EBUS]-guided) if the patient management requires a pathological result and no superficial lymphadenopathy is easily accessible. Unfortunately, EUS-TA may sometimes be challenging or inconclusive, due to blood contamination or insufficient material.

EUS elastography (EUS-E) is a non-invasive ultrasound technique that measures the hardness of tissues. The level of hardness of region of interest (ROI) can be evaluated using qualitative scores and/or quantitative methods (strain ratio; SR).

To date, most of the studies on EUS-E have been carried out using the Hitachi ultrasound machine. In particular, Paterson performed a quantitative analysis considering as a pathological value cut-off, the SR ≥7.5 for EUS-E in the nodal staging of esophageal cancer. The study involved 53 LNs using cytology as gold standard: their data showed that EUS-E had a sensitivity of 83%, specificity of 96%, PPV of 95% and NPV of 86%.

Recently, a new compact ultrasound processor, EU-ME2 (Olympus SE & CO. KG, Hamburg, Germany) that includes an elastography software was developed although data regarding its application in LNs evaluation are still not available. The concept of fractal geometry as a tool for describing natural objects was originally introduced by Benoit Mandelbrot. A fractal can be considered as an irregularly shaped object and that can be divided into fragments, each of them representing a self-similar reduced copy of the whole. The hun body is an example of natural fractal, as many of its parts are characterized by features resembling the typical fractal nature. It has been demonstrated that fractal geometry can be used to efficiently evaluate the geometrical complexity of imaging patterns observed in oncology.

The investigators recently published a study on the role of EUS elastography and fractal based analysis in the differentiation of solid pancreatic lesions. However, data regarding the application of fractal analysis to evaluate lymphadenopathies are still not available.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • patients with identified enlarged lymph nodes;
  • patients >18 years old.

排除标准

  • patients who decline to participate in the study
  • patients with contraindication to the procedure

结局指标

主要结局

Accuracy of quantitative EUS-E (strain ratio)

时间窗: 24 Months

The primary aim of this study is to evaluate the accuracy of quantitative EUS-E (strain ratio) for the diagnosis of malignancy in enlarged lymph nodes.