Assessment of Surface Coverage of Polymer-based Sirolimus-eluting Stent( Cypher ) or Polymer-free Paclitaxel-eluting Stent (YinYi )in Diabetes Mellitus and Non- Diabetes Mellitus Patients by Optical Coherence Tomography
试验速览
- 阶段
- 不适用
- 状态
- 终止
- 发起方
- 入组人数
- 120
- 试验地点
- 1
- 主要终点
- To investigate the difference of surface coverage pattern between diabetic patients and non-diabetic patients after DES (Cypher stent or YINYI stent)implantation
研究概览
简要总结
Diabetic patients are prone to a diffuse and rapidly progressive form of atherosclerosis. Both clinical and angiographic outcomes following percutaneous coronary intervention (PCI) are poor in patients with DM compared with those without DM. Autopsy study has shown delayed neointimal healing with inadequate endothelialization and persistent stent surface fibrin deposition after DES implantation in DM patients. This might partially contribute to the high risk of late stent thrombosis.
YINYI Polymer-Free paclitaxel stent is a domestic new type stent with bare metal base with micro porous surface. However, limited data is available in vivo about the surface coverage after stent implantation in DM patients because of lack of sensitive imaging modalities. Optical coherence tomography (OCT) is an optical analogue of intravascular ultrasound(IVUS)that allows high-resolution tomographic intravascular imaging. Furthermore, several studies have demonstrated the feasibility of OCT to quantitatively evaluate the surface coverage and stent conditions in the follow up after PCI .
Therefore, the aim of this study was to analyze the surface coverage and late malapposition after two types of DES implantation in DM patients compared with non-DM patients by using OCT and IVUS
详细描述
Diabetic patients are prone to a diffuse and rapidly progressive form of atherosclerosis. Both clinical and angiographic outcomes following percutaneous coronary intervention (PCI) are poor in patients with DM compared with those without DM. Autopsy study has shown delayed neointimal healing with inadequate endothelialization and persistent stent surface fibrin deposition after DES implantation in DM patients. This might partially contribute to the high risk of late stent thrombosis.
YINYI Polymer-Free paclitaxel stent is a domestic new type stent with bare metal base with micro porous surface. However, limited data is available in vivo about the surface coverage after stent implantation in DM patients because of lack of sensitive imaging modalities. Optical coherence tomography (OCT) is an optical analogue of intravascular ultrasound(IVUS)that allows high-resolution tomographic intravascular imaging.
Therefore, the aim of this study was to analyze the surface coverage and late malapposition after two types of DES implantation in DM patients compared with non-DM patients by using OCT and IVUS
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Single Group
- 主要目的
- Treatment
- 盲法
- Single (Outcomes Assessor)
入排标准
- 年龄范围
- 18 Years 至 75 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •General Inclusion Criteria:
- •Age : 18-75Y
- •Patients diagnosed as type 2 DM or non-DM.
- •Angiographic Inclusion Criteria:
- •Patients were considered eligible if they have one significant (>70%) angiographic stenosis lesions in native coronary vessel by CAG.
- •Each target is de novo lesion that can be treated with 1-2 stents.
- •Reference vessel diameter of 2.5 to 4.0 mm.
排除标准
- •General Exclusion Criteria:
- •ST-segment elevation myocardial infarction within 7 days prior to the index procedure.
- •Life expectancy <12 months due to another medical condition.
- •Contraindication to antiplatelet therapy or a history of hypersensitivity to sirolimus and paclitaxel or structurally related compounds.
- •Creatinine level more than 2.0mg/dL or ESRD.
- •Severe hepatic dysfunction (more than 3 times normal reference values).
- •Planned surgery procedure≤12 months post-index procedure.
- •Known allergy to stainless steel.
- •Female of childbearing potential with a positive pregnancy test within 7 days before the index procedure, or lactating, or intends to become pregnant during the 12 months post index procedure.
- •Patient is not clinically appropriate for OCT evaluation in the opinion of investigator.
- •Angiographic Exclusion Criteria:
- •Study lesion is ostial in location (within 3.0 mm of vessel origin).
- •Study lesion involving arterial segments with highly tortuous anatomy.
- •Complex lesion morphologies (bifurcation needs two stents technique, left main lesion, chronic obstructive occlusion, severe thrombus, heavy calcification).
结局指标
主要结局
To investigate the difference of surface coverage pattern between diabetic patients and non-diabetic patients after DES (Cypher stent or YINYI stent)implantation
时间窗: 6 months
To investigate the difference of surface coverage pattern between diabetic patients and non-diabetic patients after DES (Cypher stent or YINYI stent)implantation
次要结局
- To investigate the difference of surface coverage pattern between diabetic patients and non-diabetic patients after DES (Cypher stent or YINYI stent) implantation(12 months)
- To investigate the incidence of malapposition between diabetic patients and non-diabetic patients after DES (Cypher stent or YINYI stent) implantation(12 months)
- To investigate the differences of surface coverage pattern,the incidence of malapposition and in-stent thrombosis between Cypher stent and YINYI in diabetic patients(6 and 12 months.)
- To investigate the differences of surface coverage pattern,malapposition and the incidence of thrombosis between Cypher stent and YINYI in non-diabetic patients(6 and 12 months.)
研究者
Yu Bo
Prof
Harbin Medical University