Evaluation of the Hemodynamic Effects of Transvenous Phrenic Stimulation
试验速览
- 阶段
- 不适用
- 发起方
- 入组人数
- 10
- 试验地点
- 2
- 主要终点
- measurement of integral time speed by cardiac transthoracic ultrasound
研究概览
简要总结
Mechanical ventilation is a cornerstone in the management of severe forms of pneumonia, acute respiratory distress syndrome. It provides essential oxygen to patients, ventilates the lungs but also has deleterious effects like any treatment, in particular by reducing cardiac output by reducing venous return. Mechanical ventilation also has effects on the diaphragm: diaphragmatic dysfunction. It is explained by a prolonged inactivity of this muscle with a reduction of muscle fibers that can settle down quickly, after only a few days of mechanical ventilation. This dysfunction results in a reduction in the latter's ability to generate intrathoracic pressure necessary for ventilation, slows the withdrawal of mechanical ventilation and lengthens the duration of stay in intensive care unit. To reduce this dysfunction, phrenic stimulation has been proposed as an alternative to remuscler the diaphragm thanks to electrodes located on a central venous catheter, also used to deliver the usual therapies in intensive care unit.
The HEMOSTIM study is interested in the effects of phrenic stimulation on regional ventilation, cardiac output and cerebral perfusion: investigator hypothesize that diaphragmatic stimulation allows an improvement of these parameters.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patient included in RESCUE 3 study, interventional arm with phrenic stimulation
- •Patient or family consent
排除标准
- •Patient not affiliated or not benefiting from a social security scheme
研究组 & 干预措施
phrenic stimulation
干预措施: phrenic stimulation (Procedure)
结局指标
主要结局
measurement of integral time speed by cardiac transthoracic ultrasound
时间窗: 1 minute
to assess the effects of phrenic stimulation on cardiac output
Measurement of increased venous return gradient in percentage (variation between the value before phrenic stimulation and the value after phrenic stimulation)
时间窗: 1 minute
To specify the mechanisms of the effect of phrenic stimulation on cardiac output
次要结局
- variation in ventilation distribution before and after phrenic stimulation measured in electrical impedance tomography(1 minute)
- Measurement of diaphragmatic stimulation on cerebral oxygenation evaluated by the Near infrared spectrometry technique(1 minute)
