跳至主要内容
临床试验/NCT04337515
NCT04337515招募中不适用

A Feasibility Study of Using the CiniMacs® Device for Alpha/Best T-Cell Depletion in Stem Cell Transplant Recipients

Christopher Dvorak1 个研究点 分布在 1 个国家目标入组 90 人开始时间: 2019年12月19日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
招募中
发起方
入组人数
90
试验地点
1
主要终点
100-day incidence of Grade III-IV acute GVHD

研究概览

简要总结

Patients in need of an allogeneic hematopoietic cell transplant (HCT) are at risk of developing graft-versus-host-disease (GVHD). In certain clinical situations, the optimal approach to minimize the risk of GVHD is to perform ex vivo alpha-beta T-cell depletion of the donor cells. However, the CliniMACS® Device is FDA-approved only for a narrow indication. All other uses of ex vivo processed cells must be done under a feasibility study protocol.

详细描述

The original CliniMACS® device (CD34 Reagent System) employs a reagent consisting of an antibody that specifically binds to blood cells that express the CD34+ surface marker (hematopoietic stem cells or blood stem cells). The CD34 antibody is conjugated to an iron-containing particle that is only nanometers in size and safe for infusion. The enrichment of CD34+ cells is accomplished by passing the antibody/magnetically-labeled cell suspension through a magnetic separation column, which is provided as part of a single-use disposable tubing set. Magnetically-labeled CD34+ target cells are retained within the separation column, while the unlabeled cells flow through. Recovery of CD34+ cells is achieved by removing the magnetic field and eluting the targeted CD34+ stem cells into a collection bag.

On January 24, 2014, the FDA approved the CliniMACS CD34 Reagent System as a Humanitarian Use Device for the prevention of graft-versus-host disease (GVHD) in patients with acute myeloid leukemia (AML) in first complete remission undergoing allogeneic HCT from a matched related donor. Humanitarian Use Device (HUD) is a device that is intended to benefit patients by treating or diagnosing a disease or condition that affects or is manifested in fewer than 4,000 individuals in the United States per year. The CliniMACS® CD34 Reagent System is now indicated for processing hematopoietic progenitor cells collected by apheresis (PBSC) from an allogeneic, Human Leukocyte Antigen (HLA)-identical matched sibling donor (MSD) to obtain a CD34+ cell-enriched population for hematopoietic reconstitution following a myeloablative preparative regimen without the need for additional GVHD prophylaxis in patients with AML in first morphologic complete remission (CR1). The approval as an HUD, however, asserts that there was sufficient information for the FDA to determine that the device does not pose an unreasonable or significant risk of illness or injury. Furthermore, the clinical data supported the premise of a "probable benefit"; in that the risk to health outweighs the risk of injury or illness from its use, taking into account the probable risks and benefits of currently available devices or alternative forms of treatment.19 The CliniMACS CD34 Reagent System was shown to meet these requirements.

Uses of the CliniMACS CD34 Reagent System beyond MSD PBSC HCT for AML in CR1 are currently not FDA approved and therefore considered research, even though CD34-selection is widely considered to be a standard-of-care option for haploidentical HCT. In Europe, the European Medicines Agency (EMA) has made the CliniMACs System components available as Conformité Européene (CE) marked medical devices, and "any clinical application of the target cells is exclusively within the responsibility of the user of a CliniMACS System."

The CD34-selection system has been widely used in haploidentical HCTs, with the first patient treated at University of California, San Francisco (UCSF) in 2002. Since then, CD34-selection has facilitated over 70 HCTs at UCSF on 2 successive protocols (#01151 and #10082). However, the removal of almost all cells beyond those which are CD34+ leads to minimal passive transfer of immunity. It is therefore complicated by a slow recovery of immunity, with high rates of life-threatening viral infections, and an appreciable degree of transplant-related mortality (TRM).

Beginning in 2014, a new approach to ex vivo processing of stem cells was developed with a goal of mainly replacing the older CD34-selection technology. This technique utilizes negative depletion of the cells thought to be most responsible for the development of aGVHD, the alpha-beta T-cell Receptor positive T-cells.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
— 至 30 Years(Child, Adult)
性别
All
接受健康志愿者

入选标准

  • Male or female 0-30 years of age at time of transplant admission
  • Documentation of a disease requiring HCT
  • A donor (mismatched related or unrelated) must be located who are healthy and willing, and whom are able to donate bone marrow (BM) or peripheral blood stem cells (PBSC). Matched related donors may be used for patients with Fanconi Anemia.
  • Written informed consent (and assent when applicable) obtained from subject or subject's legal representative and ability for subject to comply with the requirements of the study

排除标准

  • Pregnant, breastfeeding, or unwilling to practice birth control during participation in the study
  • Presence of a condition or abnormality that in the opinion of the Investigator would compromise the safety of the patient or the quality of the data
  • Presence of a healthy and willing HLA-identical related donor (except when the patient has Fanconi Anemia).
  • Patient with an anticipated life expectancy of <1 month
  • Patients with known hypersensitivity to murine (mouse) proteins or iron dextran

研究组 & 干预措施

Patients receiving allogeneic hematopoietic cell transplant

Experimental

The test product is a stem cell product which has been alpha-beta T- cell depleted using the CliniMACS system. Alpha-beta T-cell depleted cells are given intravenously over a period of time as dictated by the final volume of the infused product (5 ml/kg/hour).

The target dose of CD34+ cells is ≥20x10^6/kg, but a minimum of

≥2.5x10^6/kg is required. The target dose of T-cell receptor (TCR) alpha-beta CD3+ cells is ≤1x10^5/kg.

干预措施: CliniMacs® (Device)

结局指标

主要结局

100-day incidence of Grade III-IV acute GVHD

时间窗: 100 days

The cumulative incidence of Grade III-IV acute GVHD at Day 100 will be summarized by incidence curves. GVHD evaluations will be performed using standard criteria.37 Patients with graft rejection will be censored.

次要结局

  • 1-year incidence of systemic steroid-requiring chronic GVHD(12 months)
  • 1-year incidence of transplant-related mortality(12 months)
  • 1-year incidence of autoimmunity requiring intervention with immunosuppressive agents as treatment.(12 months)
  • 30-day incidence of engraftment(30 days)
  • 180-day incidence of T-cell reconstitution (CD4+ T-cell count >200 and proliferation to PHA >50% control).(180 days)

研究者

发起方
Christopher Dvorak
申办方类型
Other
责任方
Sponsor Investigator
主要研究者

Christopher Dvorak

Professor of Pediatrics

University of California, San Francisco

研究点 (1)

Loading locations...