Cathodal Transcranial Direct Current Stimulation (tDCS) in Mild Cognitive Impairment (MCI): A Randomized, Double-Blind, Sham-Controlled Pilot Study

Mayo Clinic2 个研究点 分布在 1 个国家目标入组 16 人开始时间: 2018年2月20日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
Mayo Clinic
入组人数
16
试验地点
2
主要终点
Change in Dimensional Change Card Sort Test

研究概览

简要总结

This study evaluates the application of non-invasive brain stimulation in the treatment of Mild Cognitive Impairment (MCI) in adults aged 55-85. Half of the participants will receive transcranial direct current stimulation (tDCS), while the other half will receive sham (like placebo) stimulation.

详细描述

The purpose of this study is to investigate whether giving transcranial direct current stimulation (tDCS) treatment using an investigational device called the Soterix tES Device (tDCS device) on the right side of the brain can improve performance on cognitive tests. Investigational means that the tDCS device is not approved by the U.S. Food and Drug Administration (FDA) for the use in this study.

tDCS is a non-invasive way to electrically stimulate the brain. The tDCS device is portable and runs on two 9-volt batteries. Electrodes from the tDCS device carry weak electrical current through the scalp and skull and into the brain. When the direction of the electric current flow is called cathodal, the brain under the site of stimulation reduces its activity.

When tasks are performed, certain parts of the brain are activated. Research studies have shown that younger adults and older adults activate similar parts of the brain when performing the same task (a memory task, for example). However, other researchers found older adults who scored worse on memory tasks, and those with Mild Cognitive Impairment, activated an additional part of the brain so both sides of the brain are activated. Researchers are not sure whether this additional activation is helpful or not. Investigators in this study believe that this extra activation may be contributing to worse performance on tasks.

It may be possible to use tDCS to reduce the brain activity on the extra activation (right) side in older adults, to resemble an activation pattern seen in younger adults (or higher scoring cohort). Using cathodal tDCS to reduce brain activity might help the brain in performing tasks.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Double (Participant, Investigator)

盲法说明

Double-blind

入排标准

年龄范围
55 Years 至 85 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Male or female outpatients with confirmed MCI diagnosis
  • Age 55-85
  • Right handed (tested using the Edinburgh handedness inventory)
  • Total PHQ-8 of ≤ 16 which signifies no severe depression
  • All participants and/or caregivers must be able to provide informed consent

排除标准

  • Neurodegenerative disease (e.g. Parkinson's, Huntington's, Multiple Sclerosis) other than MCI
  • Previous brain lesion
  • Intracranial abnormality such as prior stroke
  • History of seizure disorder or epilepsy
  • A "true" positive response, after patient clarification, to any question on the modified TMS/tDCS Adult Safety Screen questionnaire that would impact patient safety
  • Any history of brain stimulation treatment (e.g., electroconvulsive therapy (ECT), repetitive transcranial magnetic stimulation (rTMS), vagal nerve therapy (VNS), deep brain stimulation (DBS))
  • Use of any investigational drug within 4 weeks
  • Cardiac pacemakers, implanted medication pumps, intracardiac lines; acute or unstable cardiac disease; intracranial implants (e.g., aneurysm clips, shunts, stimulators, cochlear implants, or electrodes) or any other metal object within or near the head (exception: mouth/dental work) that cannot be safely removed
  • Known or suspected pregnancy (extremely unlikely as the age range for this study is 55-85 years)

结局指标

主要结局

Change in Dimensional Change Card Sort Test

时间窗: Baseline, 1 month post intervention

Post-intervention score comparison between the intervention and control group measured by the NIH Toolbox Cognition Battery Test. The NIH Toolbox Cognition Battery Test is a comprehensive set of neuro behavioral measurements used to assess cognitive, sensory and motor functions where a higher composite score equals better cognitive performance. The NIH Toolbox Cognitive Scores used the Fully Adjusted Scale score (also referred to as the fully corrected T-score) with a mean of 50 and standard deviation of 10.

Change in Picture Sequence Memory Test v2.1 Score

时间窗: Baseline, 1 month post intervention

Post-intervention score comparison between the intervention and control group measured by the NIH Toolbox Cognition Battery Test. The NIH Toolbox Cognition Battery Test is a comprehensive set of neuro behavioral measurements used to assess cognitive, sensory and motor functions where a higher composite score equals better cognitive performance. The NIH Toolbox Cognitive Scores used the Fully Adjusted Scale score (also referred to as the fully corrected T-score) with a mean of 50 and standard deviation of 10.

Change in Flanker Inhibitory Control and Attention Test Scores

时间窗: Baseline, 1-month post intervention

Post-intervention score comparison between the intervention and control group measured by the NIH Toolbox Cognition Battery Test. The NIH Toolbox Cognition Battery Test is a comprehensive set of neuro behavioral measurements used to assess cognitive, sensory and motor functions where a higher composite score equals better cognitive performance. The NIH Toolbox Cognitive Scores used the Fully Adjusted Scale score (also referred to as the fully corrected T-score) with a mean of 50 and standard deviation of 10.

Change in Picture Vocabulary Test Scores

时间窗: Baseline, 1 month post intervention

Post-intervention score comparison between the intervention and control group measured by the NIH Toolbox Cognition Battery Test. The NIH Toolbox Cognition Battery Test is a comprehensive set of neuro behavioral measurements used to assess cognitive, sensory and motor functions where a higher composite score equals better cognitive performance. The NIH Toolbox Cognitive Scores used the Fully Adjusted Scale score (also referred to as the fully corrected T-score) with a mean of 50 and standard deviation of 10.

Change in Oral Reading Recognition Test Score

时间窗: Baseline, 1 month post intervention

Post-intervention score comparison between the intervention and control group measured by the NIH Toolbox Cognition Battery Test. The NIH Toolbox Cognition Battery Test is a comprehensive set of neuro behavioral measurements used to assess cognitive, sensory and motor functions where a higher composite score equals better cognitive performance. The NIH Toolbox Cognitive Scores used the Fully Adjusted Scale score (also referred to as the fully corrected T-score) with a mean of 50 and standard deviation of 10.

Change in List Sorting Working Memory Test Scores

时间窗: Baseline, 1 month post intervention

Post-intervention score comparison between the intervention and control group measured by the NIH Toolbox Cognition Battery Test. The NIH Toolbox Cognition Battery Test is a comprehensive set of neuro behavioral measurements used to assess cognitive, sensory and motor functions where a higher composite score equals better cognitive performance. The NIH Toolbox Cognitive Scores used the Fully Adjusted Scale score (also referred to as the fully corrected T-score) with a mean of 50 and standard deviation of 10.

Change in Pattern Comparison Processing Speed Test Scores

时间窗: Baseline, 1 month post intervention

Post-intervention score comparison between the intervention and control group measured by the NIH Toolbox Cognition Battery Test. The NIH Toolbox Cognition Battery Test is a comprehensive set of neuro behavioral measurements used to assess cognitive, sensory and motor functions where a higher composite score equals better cognitive performance. The NIH Toolbox Cognitive Scores used the Fully Adjusted Scale score (also referred to as the fully corrected T-score) with a mean of 50 and standard deviation of 10.

次要结局

未报告次要终点

研究者

发起方
Mayo Clinic
申办方类型
Other
责任方
Principal Investigator
主要研究者

Yonas E Geda, MD

Professor of Neurology and Psychiatry

Mayo Clinic

研究点 (2)

Loading locations...

相似试验