跳至主要内容
临床试验/NCT04562701
NCT04562701已完成不适用

Relationship Between Hamstring Length and Gluteus Maximums Strength With and Without Normalization in Mechanical Low Back Pain

Cairo University1 个研究点 分布在 1 个国家目标入组 73 人开始时间: 2018年9月10日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
73
试验地点
1
主要终点
Gluteus muscle torque

研究概览

简要总结

The aim of this study was to determine the correlation between hamstring length and gluteus maximus strength with and without normalization in patients with mechanical low back pain

详细描述

seventy-three patients diagnosed as mechanical low back pain. Firstly, gluteus maximus (GM) strength was measured isometrically as a force (kg) and then converted to torque (Nm). GM strength was normalized for body weight and height using the following formula: % (body weight × h) = torque (N × m) ×100 / body weight (N) × h (m), then assessment of hamstring length flexibility using the active knee extension method.

Data was collected and the correlation was determined.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Cross Sectional

入排标准

年龄范围
18 Years 至 40 Years(Adult)
性别
All
接受健康志愿者

入选标准

  • 未提供

排除标准

  • History of previous fractures, surgeries, malignancies, trauma, rheumatoid arthritis, spondylosis, and spondylolisthesis.
  • History of lower limb injuries in the last six months before the study.
  • Inability to correctly produce maximal Gluteus Maximus contraction in a pain-free ROM.

结局指标

主要结局

Gluteus muscle torque

时间窗: 20 minutes

The gluteus maximus strength was evaluated by using hand-held dynamometer (HHD). The patient was asked to lie in the prone position. Belt was used to support the pelvis, then the patient was asked to maximally extend the hip joint with the knee joints flexed to 90°). Resistance belt (non-elastic strap) was placed 15 cm above the knee joint above popliteal fossa with the Hand-held dynamometer below it. Each subject was instructed to perform maximal isometric hip extension for 5 seconds. Measurement was done three times, with 2-minutes rest between trials. Subject's hand was places behind waist to control the substitute motions of arm or hand. The peak force for each trial was recorded, and the average value was calculated

Hamstring length

时间窗: 20 minutes

Patient was positioned supine with the non-tested limb flat with knee extended and supported with strap over the mid-thigh to eliminate any substitutive movement. An another strap was rapped over the pelvis for fixation, to maintain 90 degrees of the hip joint, a wooden frame was then placed on the plinth in line with the participant's anterior superior iliac spine of the pelvis. The participant was asked to flex the hip of the test leg so that their thigh touching the wooden apparatus all over test time

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Nasr Awad Abdelkader Othman

Lecturer

Cairo University

研究点 (1)

Loading locations...