Validation of Fitbit Measurements in Hospitalized General Medicine Patients
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 33
- 试验地点
- 2
- 主要终点
- Fitbit Sense 2 vs. StepWatch for activity (step count)
研究概览
简要总结
Patients admitted to the General Internal Medicine ward are sick and in need of monitoring that cannot be provided at home or treatments best administered in hospital. Standard care currently includes vital signs measurements and in some cases ECG. Wearable devices that continuous monitor patients could provided added information to improve the care of inpatients. This could include more monitoring and catching deterioration before it happens. Wearables have been shown to be largely accurate for monitoring heart rate, however it is still necessary to determine if they can reliably measure sleep, activity, and other health metrics. For this, study investigators are evaluating the validity of FitBit Sense 2 (or other FitBit devices) for measurement of sleep, activity, heart rate, respiratory rate, and oxygen saturation.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Subject inclusion criteria.
- •General internal medicine patients admitted to General Medicine Wards.
- •Able to consent.
- •18 years of age or older
排除标准
- •Patients who are purely palliative "comfort measures only" where measuring vital signs would not be appropriate and will be excluded.
- •To reduce the potential risk of transmitting nosocomial infections, patients under contact precautions for methicillin resistant Staphylococcus aureus (MRSA) and Clostridium difficile infections will also be excluded.
- •This study will also exclude patients at risk of vascular compromise of the arm or leg on which the wearable device was to be placed, such as patients with deep venous thrombosis, dialysis fistulas, and severe upper extremity trauma.
- •Expected discharge less than 24 hours
研究组 & 干预措施
General internal medicine patients admitted to General Medicine Wards
Intervention: Fitbit Sense 2 (Fitbit, San Francisco, CA, USA)
Gold standard devices: To compare measures, patients will be asked to wear the following for 24 hours:
- Sleep study device - Nox T3 chest band with oximeter. Participants will be asked to wear this for 24 hours. The Nox T3 monitors chest movement and determines sleep stages. It is paired with a Nonin oximeter. This provides continuous oxygen saturation monitoring as well as heart rate and respiratory rate.
- Step counter - An ankle-worn Stepwatch Activity Monitor which has been validated in hospital patients who move slowly.
结局指标
主要结局
Fitbit Sense 2 vs. StepWatch for activity (step count)
时间窗: Collected over 24 hours in 1 min bins
Comparisons of step counts between Fitbit and Modus StepWatch
Fitbit Sense 2 vs. Nox T3 for heart rate (bpm)
时间窗: Fitbit collected over 24 hours in 1 min bins and Nox T3 collected during nighttime sleep in 1 sec bins
Comparisons of HR between Fitbit and Nox pulse oximeter
Fitbit Sense 2 vs. Nox T3 for respiratory rate (breaths per minute)
时间窗: Fitbit collected over 24 hours in 1 min bins and Nox T3 collected during nighttime sleep in 1 sec bins.
Comparisons of RR between Fitbit and Nox RIP (respiratory inductive plethysmograph)
Fitbit Sense 2 vs. Nox T3 for oxygen saturation (SpO2, %)
时间窗: Fitbit collected over 24 hours in 1 min bins and Nox collected during nighttime sleep in 1 sec bins.
Comparisons of SpO2 between Fitbit and Nox T3
Fitbit Sense 2 vs. Nox T3 for total sleep time (min)
时间窗: Fitbit and Nox T3 collected during nighttime sleep (1 night)
Comparisons of sleep TST between Fitbit and Nox T3
Fitbit Sense 2 vs. Nox T3 for sleep efficiency (%)
时间窗: Fitbit and Nox T3 collected during nighttime sleep (1 night)
Comparisons of SE between Fitbit and Nox T3
Fitbit Sense 2 vs. Nox T3 for sleep stages (%, min)
时间窗: Fitbit and Nox T3 collected during nighttime sleep (1 night)
Comparisons of sleep stages (NREM - stage 1-3, REM) between Fitbit and Nox T3
Fitbit Sense 2 vs. Nox T3 for wake after sleep onset (min)
时间窗: Fitbit and Nox T3 collected during nighttime sleep (1 night)
Comparisons of WASO between Fitbit and Nox T3
Fitbit Sense 2 vs. Nox T3 for time of sleep onset and wake time
时间窗: Fitbit and Nox T3 collected during nighttime sleep (1 night)
Comparisons of sleep onset time and wake time between Fitbit and Nox T3
次要结局
- Fitbit Sense 2 vs. Sleep Diary for total sleep time (min)(Collected during nighttime sleep (1 night))
- Fitbit Sense 2 vs. Sleep Diary for sleep efficiency (%)(Collected during nighttime sleep (1 night))
- Fitbit Sense 2 vs. Sleep Diary for time of sleep schedule(Collected during nighttime sleep (1 night))
- Fitbit Sense 2 vs. Sleep Diary for wake after sleep onset (min)(Collected during nighttime sleep (1 night))
- Subgroup analysis based on gender(Collected at study baseline)
- Subgroup analysis based on comorbidities(Collected at study baseline)
- Subgroup analysis based on use of walking aids(Collected at study baseline)
研究者
Robert Wu
Clinician Investigator
University Health Network, Toronto