Toric Contact Lens Digital Performance and Comfort Study

Kathryn Richdale2 个研究点 分布在 1 个国家目标入组 30 人开始时间: 2021年3月16日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
30
试验地点
2
主要终点
Near Visual LogMAR Acuity

研究概览

简要总结

This study seeks to quantify digital visual performance and subjective visual acceptance of toric contact lenses as compared to spherical lenses in low to moderate astigmatic patients.

详细描述

This study seeks to quantify the near visual performance and subjective visual acceptance of toric contact lenses as compared to spherical lenses in an astigmatic cohort of patients. Primary Hypotheses: Subjects will have better near visual acuity and near visual performance with toric, as opposed to spherical, contact lens correction. As such, the following hypotheses will be tested: H01: There is no statistically significant difference in near visual acuity or near vision performance between contact lenses corrections Ha1: There is a statistically significant difference in visual acuity or vision performance between contact lenses corrections

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Treatment
盲法
Double (Participant, Investigator)

入排标准

年龄范围
18 Years 至 39 Years(Adult)
性别
All
接受健康志愿者

入选标准

  • 18 to 39 years of age (inclusive)
  • pl to -6.00D vertexed sphere power and -0.75 to -1.50D vertexed refractive cylinder OD and OS
  • Current/established full time (>6 days week, >8 hours/day) soft contact lens wearer
  • Best corrected acuity of 20/25 or better in each eye
  • Self-report of at least 4 hrs/day using digital devices
  • Willing to wear lenses at least 8 hours each day during the study period
  • Able to speak and read English at a high school level / have at least a high school diploma or equivalent (by self-report)
  • Enclusion Criteria:
  • History of ocular pathology or surgery
  • Binocular vision disorder (i.e., tropia, convergence or accommodative insufficiency)
  • Gas permeable lens wear for at least 3 months
  • Symptomatic soft contact lens wearer (CLDEQ-8 score <12 at baseline)

排除标准

  • 未提供

结局指标

主要结局

Near Visual LogMAR Acuity

时间窗: 10 +/- 2 days

High contrast LogMAR visual acuity was assessed at 40 cm using the M\&S Clinical Trial Suite system (Niles, Illinois, USA). The system was calibrated according to the manufacturer's directions every day, prior to use. Testing was performed binocularly 10+/-2 days after each intervention. The test started at 20/60 and continued until three letters were missed on a line.

Dynamic Visual Acuity

时间窗: 10 +/- 2 days

Dynamic VA was determined using a custom-made iPad application. The subject was instructed to hold the iPad at 40cm and presented with a Landolt C surrounded by crowding bars for 0.3s each, starting from 0.5 LogMAR and progressing to smaller sizes using a staircase threshold method. Testing was performed binocularly 10+/-2 days after each intervention

次要结局

未报告次要终点

研究者

发起方
Kathryn Richdale
申办方类型
Other
责任方
Sponsor Investigator
主要研究者

Kathryn Richdale

Associate professor