Early Recurrences of Atrial Arrhythmias and Their Impact on Late Recurrence After Pulmonary Vein Isolation With Pulsed Field Ablation of Paroxysmal Atrial Fibrillation
试验速览
- 阶段
- 不适用
- 状态
- 招募中
- 发起方
- 入组人数
- 40
- 试验地点
- 1
- 主要终点
- Number of participants with AF recurrence 3-12 months post-procedure
研究概览
简要总结
This is a prospective, single-arm study conducted in University Hospital of Split, Department of Cardiology. Patients treated with PFA for symptomatic paroxysmal atrial fibrillation will be asked to participate in the study. An implantable loop recorder (ILR) will be placed immediately after the PFA procedure for rhythm monitoring. Early recurrences will be subsequently divided into very early recurrences (up to 1 month post-procedure) and early recurrences (1-3 months post-procedure). Late recurrences will be defined as those 3 to 12 months post-procedure. Patients will be monitored routinely through follow up visits during which ILR will be interrogated and eventual symptoms will be assessed. Follow-up visits will be scheduled 1, 3, 6, 12 months post-procedure. Median follow-up will be 12 months. Data for the study will be obtained from a loop monitor to assess the arrhythmia burden during follow-up visits in the University Hospital of Split Arrhythmia Clinic.
详细描述
This is a prospective, single-arm study conducted in the University Hospital of Split, Department of Cardiology. Patients treated with PFA for symptomatic paroxysmal atrial fibrillation will be asked to participate in the study. An implantable loop recorder (ILR) will be placed immediately after the PFA procedure for rhythm monitoring. Early recurrences will be subsequently divided into very early recurrences (up to 1-month post-procedure) and early recurrences (1-3 months post-procedure). Late recurrences will be defined as those 3 to 12 months post-procedure. Patients will be monitored routinely through follow-up visits during which ILR will be interrogated and eventual symptoms will be assessed. Follow-up visits will be scheduled 1, 3, 6, and 12 months post-procedure. The median follow-up will be 12 months. Data for the study will be obtained from a loop monitor to assess the arrhythmia burden during follow-up visits in the University Hospital of Split Arrhythmia Clinic.
For PVI, the "single-shot" multielectrode PFA catheter will be used. This catheter consists of 5 splines, with 4 electrodes per spline and 1 electrode available for intracardiac electrogram recording or 3-dimensional electroanatomic visualization. When used in conjunction with the PFA generator, an electric field is created that ablates tissue using irreversible electroporation. The catheter shape is changed through the manipulation of a slider mechanism on the handle of the catheter. The diameter of the catheter is measured in the fully deployed "flower" configuration and is available in 2 sizes (31 or 35 mm). Energy is delivered through all of the electrodes in a proprietary sequence.
All patients will be asked to provide written informed consent for their respective protocol before undergoing the study.
All procedures will be performed with conscious sedation and propofol bolus synchronized to sets of PFA applications. The procedures will be performed with uninterrupted oral anticoagulation, and left atrial thrombus will be excluded either through pre-procedure CT or intracardiac echocardiography (ICE) (AcuNav, Siemens, Munich, Germany) at the time of the procedure. Pre- and post-ablation diaphragm motion will be evaluated to observe changes in phrenic nerve function during the procedure. Esophageal temperature monitoring will not be utilized due to the nonthermal nature of PFA.
A single transseptal puncture will be performed with an 8.5-F sheath and exchanged for the 13-F PFA sheath in the left atrium, or a transseptal puncture will be performed directly with the PFA sheath. Intravenous heparin will be administered as boluses and continuous infusions to obtain an activated clotting time ≥300 s prior to ablation and throughout the procedure. A 0.035-inch, 180-cm extra-stiff, straight guidewire will be used to cannulate each vein over which the multielectrode PFA catheter will be deployed into the desired shape and advanced into position at the antrum of each vein. The antral level of catheter positioning will be monitored with ICE imaging and fluoroscopy. Patients with left common PV anatomy will receive therapy at the level of the common antrum with 2 sets of therapy delivered, 1 with the guidewire in a superior branch and 1 with the guidewire in an inferior branch.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 75 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Index PFA procedure after one failed or intolerant group I or III of the antiarrhythmic drug in patients with symptomatic paroxysmal AF (AF with self-terminating episodes lasting no longer than 7 continuous days)
- •Willing and able to provide informed consent.
排除标准
- •Any known contraindication to AF ablation or anticoagulation.
- •History of previous left atrial ablation or surgical treatment.
- •Secondary AF due to reversible or non-cardiac cause such as thyroid disease and electrolyte imbalance.
- •Asymptomatic AF patients, persistent AF, permanent AF patients.
- •History of clotting or bleeding disease or cryoglobulinemia.
- •Pregnant or lactating.
- •Other conditions that may make the patient a poor candidate for procedure such as mental illness, terminal illness, vulnerable patient population.
结局指标
主要结局
Number of participants with AF recurrence 3-12 months post-procedure
时间窗: 12 months
Number of participants with AF recurrence 3-12 months post-procedure (AF burden defined by loop recorder findings)
次要结局
- Adverse event rate(12 months)
- Number of patients with very early AF recurrence (within 1 month post procedure)(12 months)
研究者
Lucija Lisica
Principal Investigator
University of Split, School of Medicine