A New Technique to Assess the Correct Positioning of a Right-sided Double-lumen Tube Without Fiberoptic Bronchoscopy

Cliniques universitaires Saint-Luc- Université Catholique de Louvain1 个研究点 分布在 1 个国家目标入组 10 人开始时间: 2017年3月10日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
10
试验地点
1
主要终点
Measurement of the distance between the lateral orifice of the tube and the orifice of the right upper lobe bronchus

研究概览

简要总结

A technique not yet described in the literature and allowing anesthesiologists who do not regularly practice fibroscopy or who do not routinely have this type of apparatus for their procedures, to install straight double-lumen tubes without compromising the ventilation of the patient. The aim is to introduce a central venous catheter wire guide into the bronchial arm of the right double-lumen tube and insert it into the right upper lobe bronchus orifice under fluoroscopic control. Then, to validate the new technique, we will carry out a fibroscopic control.

详细描述

Right-sided double lumen tube (Mallinckrodt - Endobronchial tube) is introduced into the glottis via direct laryngoscopy. After the endotracheal lumen tube has passed the vocal cords, the stylet is removed, and the tube is rotated 90° toward the right and advanced slightly until resistance is encountered. Auscultation is then performed to check the proper side the endobronchial tube was inserted to.

Then, the anatomy of the carina and the origins of the right and left upper bronchus are identified with the video-bronchoscopy.

After a mild plication of the distal extremity of an adult central venous catheter wire guide (0.53mm diameter, 45cm length, one straight soft tip on one end and one "J" tip on other), the J-shaped extremity of this guide is introduced through the endobronchial lumen under direct video-bronchoscope. The wire guide is then slowly removed in order that proper alignment between the wire extremity and the right upper lobe occurs. The wire is removed again until its J-shaped extremity appears through the right-upper lobe ventilation orifice. In order to align the orifice of the tube with the upper lobe bronchus, a rotational movement of the double-lumen tube may be necessary. When the location of the orifice of the right upper lobe is identified, the guide is moved forward through the orifice into the upper lobe bronchus.

Once satisfactory initial placement is achieved, the bronchial cuff is left inflated, the wire guide of the central venous catheter is kept in place in the upper lobe bronchus, and the patient is turned to the right lateral decubitus position. The proper positioning of the tube is once again checked by another video-bronchoscopy.

To confirm the exact placement of the tube, a fiberoptic bronchoscopy is performed through the endobronchial lumen to find the right upper lobe ventilation orifice and confirm alignment. Then, it is placed distally to the endobronchial lumen to confirm a clear view showing the bronchus intermedius.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Crossover
主要目的
Device Feasibility
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •all patients > 18 years old who have to undergo a left thoracic surgery with a one lung ventilation technique

排除标准

  • •emergency surgical procedures, patients with predictable difficulties of insertion of a double-lumen endotracheal tube, hemodynamically unstable patients

研究组 & 干预措施

Positioning of right-sided double lumen tube with fluoroscopy

Experimental

positioning of the right-sided double lumen tube with a wire guide and fluoroscopy

干预措施: right-sided double lumen tube (Procedure)

Positioning of right-sided double lumen tube with fibroscope

Experimental

positioning of the right sided double lumen tube in the same patient but with a fibroscope

干预措施: right-sided double lumen tube (Procedure)

结局指标

主要结局

Measurement of the distance between the lateral orifice of the tube and the orifice of the right upper lobe bronchus

时间窗: 20 minutes

Fibroscopic measurement to assess the correct positioning of the right-sided double lumen tube with the wire guide and the fluoroscopy

次要结局

  • Total time spent to correctly position the right-sided double lumen tube(20 minutes)