跳至主要内容
临床试验/NCT01729637
NCT01729637已完成不适用

Normothermic Ex-vivo Lung Perfusion: Clinical Experience of the Pressure/Time Curve Profile Study (Stress Index)

University of Turin, Italy1 个研究点 分布在 1 个国家目标入组 11 人开始时间: 2011年7月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
11
试验地点
1
主要终点
Presence of mechanical stress as assessed by analysis of the "Stress Index"

研究概览

简要总结

In order to minimize mechanical stress the investigators propose to implement EVLP procedure with a ventilation monitoring guided by the analysis of the Paw-t shape.

详细描述

Increase of interest about technique of Ex-Vivo Lung Perfusion (EVLP) has highlighted the need of new approaches to respiratory mechanics monitoring to prevent lung stress in atypical physiological settings.

Airway pressure/time curve (Paw-t) shape analysis at constant flow ventilation (Stress Index, SI) is thought to be predictor of lung stress; so the SI coefficient may therefore identify and quantify mechanical stress during ventilation. (1) In experimental studies, the threshold values for SI that best discriminated lungs with signs of Ventilator Induced Lung Injury ranged between 0.9 and 1.1. (2) During EVLP, the isolated lungs are free from the effect of chest wall impairment and represent the effective response of lung parenchyma to ventilatory setting.

Use of SI monitoring in isolated and perfuse lung reconditioning, may be an useful tool to prevent hyperinflation and opening-closing conditions by titrating optimal protective ventilation As previously reported by our group, in the first trial of lung reconditioning, signs of mechanical stress were detected with Paw-t curve. (3) Therefore we implemented EVLP procedure with continuous stress index analysis to detect and quantify the occurrence of hyperinflation or opening closing condition.

研究设计

研究类型
Observational
时间视角
Prospective

入排标准

年龄范围
65 Years 至 —(Older Adult)
性别
All
接受健康志愿者

入选标准

  • High risk donor lung, define as:
  • the ratio of partial pressure arterial oxygen and fraction of inspired oxygen less than 300
  • pulmonary edema
  • poor lung deflation or inflation
  • blood transfusions exceeding 10 units
  • donation after cardiac death as defined by Maastricht category III o IV

排除标准

  • donors lung with established pneumonia
  • donors lung with severe mechanical lung injury
  • donors lung with gross gastric aspiration

结局指标

主要结局

Presence of mechanical stress as assessed by analysis of the "Stress Index"

时间窗: During EVLP procedure (4 hours)

Stress index is the exponential coefficient of the equation describing the shape of the airway opening pressure vs time (Paw-t) curve during constant flow. This approach is based on the observation that, at constant flow the rate of change of the Paw-t curve corresponds to the rate of change of the compliance of the respiratory system during tidal inflation. A progressive increase in slope (i.e. a downward concavity of the curve) indicates that compliance is progressively increasing with tidal inflation (tidal recruitment). A progressive decrease in slope (i.e. a upward convexity of the curve) indicates that compliance is decreasing with tidal inflation (tidal hyperinflation). Clinical and experimental data show that presence of Stress Index values indicating mechanical stress are associated to morphological, histological and inflammatory evidence of ventilator induce lung injury.

次要结局

  • Association between values of Stress Index and occurrence of physiological criteria for EVLP success(During EVLP procedure (4 hours))

研究者

发起方
University of Turin, Italy
申办方类型
Other
责任方
Principal Investigator
主要研究者

Marco Ranieri

MD Professor

University of Turin, Italy

研究点 (1)

Loading locations...