简要总结
This clinical investigation of the hepatocyte matrix implant is an evaluation blinded non-randomized and monocentric pilot study of Phase I, which is conducted as a therapeutic investigation. Randomization is not possible due to ethical and practical reasons. This study has already been approved in Switzerland and has been adapted to Indonesian Law and disease.
This new treatment procedure has already been successfully used on the basis of compassionate use in Germany. The hepatocyte matrix implant is a new patented procedure consisting of bio-matrix technology. A formaldehyde-free special matrix consisting of self-dissolving polymers is applied as a carrier substance and is cultivated with human autologous cells using a special technique. Clinically the bio artificial liver replacement tissue for patients with end-stage hepatic disease has been developed as a first application. In this procedure autologous hepatocytic tissue and pancreatic tissue is removed (liver resection and pancreatic biopsy) from the patient in a first surgical procedure. The tissue is sent to a specialized Cell Culture Laboratory. The laboratory is GMP certified for this procedure. The cells are processed according to SOPs in a special perfusion procedure and prepared on several platelets of matrices (platelets of 20 mm diameter and 4mm thickness). After completion of the laboratory process the bio tissues are implanted into the mesentery of the small intestine during a second operation. The cells are growing controlled on the matrix, take on the capillaries of the patient and thus connect to the blood circulation. The implanted cells multiply by a specific factor and independently take over the metabolic function of the original liver after two to four weeks. In the following process the carrier matrix dissolves completely and implanted cells develop into liver cell tissue.
详细描述
This new treatment procedure has already been successfully used on the basis of individual treatment in Germany. The hepatocyte matrix implant is a new patented procedure consisting of bio-matrix technology. A formaldehyde-free special matrix consisting of self-dissolving polymers is applied as a carrier substance and is cultivated with human autologous cells using a special technique. Clinically the bio artificial liver replacement tissue for patients with end-stage hepatic disease has been developed as a first application. In this procedure autologous hepatocytic tissue and pancreatic tissue is removed (liver resection and pancreatic biopsy) from the patient in a first surgical procedure. The tissue is sent to a specialized Cell Culture Laboratory. The laboratory is GMP certified for this procedure. The cells are processed according to SOPs in a special perfusion procedure and prepared on several platelets of matrices (platelets of 20 mm diameter and 4mm thickness). After completion of the laboratory process the bio tissues are implanted into the mesentery of the small intestine during a second operation. The cells are growing controlled on the matrix, take on the capillaries of the patient and thus connect to the blood circulation. The implanted cells multiply by a specific factor and independently take over the metabolic function of the original liver after two to four weeks. In the following process the carrier matrix dissolves completely and implanted cells develop into liver cell tissue.
研究设计
- 研究类型
- Interventional
- 分配方式
- Non Randomized
- 干预模型
- Single Group
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 20 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •endstage liver disease
- •stable and non-improving liver condition for at least 3 month
- •alcoholic liver cirrhosis: proven alcohol abstinence for 6 month or more
- •patient in bad general condition
排除标准
- •pregnancy
- •drug addiction (except alcohol)
- •psychiatric disease
- •HIV positive
- •peritoneal carcinosis
- •hereditary liver disease
- •acute liver failure
结局指标
主要结局
Evaluation of clinical and laboratory parameters of liver function
时间窗: 6 months
Evaluation of clinical parameters MELD, CHILD, Asictes, portal hypertension in comparison of values measured 3 and 6 months before operation Evaluation of laboratory parameters Bilirubin, ASAT, ALAT, alkaline phosphatase, cholinesterase, albumin, total protein
次要结局
未报告次要终点