跳至主要内容
临床试验/NCT01320566
NCT01320566终止2 期

A Continuation Study of the AeriSeal® System Administered at 3 to 4 Sites During a Single Treatment Session for Lung Volume Reduction in Patients With Advanced Emphysema

Aeris Therapeutics4 个研究点 分布在 1 个国家目标入组 18 人开始时间: 2011年3月1日最近更新:
适应症

试验速览

阶段
2 期
状态
终止
发起方
入组人数
18
试验地点
4
主要终点
Change from baseline in Percent Volume of Lung

研究概览

简要总结

The purpose of this study is to assess the long term safety and efficacy of AeriSeal System treatment administered at up to 4 subsegments during a single treatment session for lung volume reduction in patients with advanced emphysema through 48 weeks after treatment.

详细描述

Emphysema is a progressive, debilitating disease characterized by destruction of lung tissue as a result of inflammation caused by exposure to noxious inhaled agents for extended periods. The most common cause of this condition is cigarette smoking, although genetic, occupational, and environmental causes account for up to 10% of cases. Despite aggressive public health initiatives aimed at discouraging the use of cigarettes, smoking-related lung diseases remain a significant cause of disability and death worldwide. Due to the number of current and new smokers, emphysema is expected to remain a leading cause of morbidity and mortality for years to come.

The AeriSeal System is a novel device system being developed for the treatment of advanced emphysema. The AeriSeal System is administered bronchoscopically, and designed to provide the physiological benefits of lung volume reduction without the risks and cost of major surgery.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
40 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients must have been enrolled in the 03-C10-002PLV Aeris' Investigational Study and completed a minimum of 12 weeks of follow-up following AeriSeal System treatment.

排除标准

  • 未提供

结局指标

主要结局

Change from baseline in Percent Volume of Lung

时间窗: 48 Weeks following treatment

Computed Tomography (CT) evidence of lobar volume reduction at site(s) of AeriSeal Foam Sealant administration at 48 weeks post treatment, assessed quantitatively by digital integration of CT dicom images collected using a standardized image acquisition and reconstruction algorithm.

次要结局

  • Change in Forced Expiratory Volume in 1 Second (FEV1)(24 and 48 weeks following treatment)
  • Change in distance walked in six minutes(24 and 48 weeks following treatment)
  • Change in the ratio of Residual Volume (RV) to Total Lung Capacity (TLC)(24 and 48 weeks following treatment)
  • Change in Forced Vital Capacity (FVC)(24 and 48 weeks following treatment)
  • Change in St. George's Respiratory Questionnaire (SGRQ)domain score(24 and 48 weeks following treatment)
  • Change in Medical Research Council Dyspnea (MRCD) score(24 and 48 weeks following treatment)

研究者

发起方
Aeris Therapeutics
申办方类型
Industry
责任方
Sponsor

研究点 (4)

Loading locations...