HIS-Purkinje Conduction System Pacing Optimized Trial of Cardiac Resynchronization Therapy
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 100
- 试验地点
- 2
- 主要终点
- Primary Endpoint
研究概览
简要总结
This is a randomized, prospective, single-blinded trial to determine the overall rate of successful His-Purkinje conduction system pacing Optimized Trial of Cardiac Resynchronization Therapy (HOT-CRT) versus biventricular pacing using coronary sinus lead (BVP) to compare acute and mid-term outcomes. Acute outcomes include change in QRS duration pre-and post-pacing (degree of QRS narrowing) and incidence of major periprocedural complications (pericardial tamponade, need for lead revision, etc.). Mid-term outcomes include echocardiographic response at 6 months along with a composite clinical outcome of heart failure hospitalization, ventricular arrhythmias, crossover, and all-cause mortality.
详细描述
This is a single-blinded study of 100 patients randomized to a strategy of His-Purkinje conduction system pacing Optimized Trial of Cardiac Resynchronization Therapy (HOT-CRT) versus biventricular pacing using coronary sinus (CS) lead (BVP). Both treatment options use standard-of-care, FDA-approved devices. The distinction is only in the allocation toward HOT-CRT and BVP. Treating physicians will be aware of assignment in order to facilitate routine device follow-up. Echocardiographic and electrocardiographic evaluation will also be performed in a blinded manner.
Cross-over is permitted between treatment group allocation if:
CS lead cannot be placed due to difficult cannulation of the CS, limited branches at the posterolateral or lateral wall, or phrenic nerve capture. These subjects may then cross-over to HOT-CRT.
HOT-CRT subjects may cross-over if His or left bundle pacing lead cannot be positioned with adequate stability and reasonable pacing output, or if optimal QRS narrowing cannot be achieved.
Implant procedure will be per routine percutaneous access, as is standard for pacemaker and Implantable Cardioverter Defibrillators (ICDs). . All subjects will receive an FDA-approved cardiac resynchronization therapy pacemaker or defibrillator device, as per standard of care outlined for the subject.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- Double (Participant, Outcomes Assessor)
盲法说明
Subjects will be blinded to treatment arm. Echocardiographic evaluation will be performed by study physician blinded to lead placement
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patients at least 18 years of age
- •Diagnosis is NYHA Class II, III, and ambulatory Class IV heart failure with either ischemic or nonischemic cardiomyopathy and patients with NYHA Class I symptoms and ischemic cardiomyopathy, with at least one of the following:
- •LV systolic dysfunction with LVEF ≤ 35% and Evidence of bundle branch block with QRS duration > 120 msec
- •LV systolic dysfunction with LVEF ≤ 50% and with need for >40% Right Ventricular (RV) pacing
排除标准
- •Existing CRT device
- •Inability of patient capacity to provide consent for themselves either due to medical or psychiatric comorbidity
- •Pregnancy
- •Participation in other device trials
- •Inability to complete study requirements
结局指标
主要结局
Primary Endpoint
时间窗: 6 months
Improvement in left ventricular ejection fraction (LVEF) - change in LVEF% measured by 2D echo at 6 months compared to baseline
Primary Safety
时间窗: 6 months
Freedom from major complications or need for CRT lead revision - complication such as lead dislodgment, pericardial tamponade, pneumothorax, systemic embolism, phrenic nerve stimulation not correctable by programming
次要结局
- Secondary Composite(6 months)
- Echocardiographic Response(6 months)
研究者
Pugazhendhi Vijayaraman
Sponsor-Investigator
Geisinger Clinic
