Establishing Normative Values for Thermal Detection and Pain Threshold Established by the Psi Method

Université Catholique de Louvain1 个研究点 分布在 1 个国家目标入组 80 人开始时间: 2020年10月10日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
暂停
入组人数
80
试验地点
1
主要终点
Fitted psychometric functions for heat pain obtained with the psi method

研究概览

简要总结

The study aims to compare different methods to assess thermal detection ability in diabetic patients, as a way to monitor and diagnose neurological complications of diabetes mellitus.

详细描述

Diabetic polyneuropathy is a frequent complication of diabetes mellitus. The impairment of peripheral nerve fibre function can be very variable, predominantly affecting large-diameter fibres (subserving touch), small-diameter fibres (subserving thermonociception), or both.

Thermal detection threshold evaluation can be used to quantify the extent of function loss (hypoesthesia) and, to a lesser extent, gain (hyperesthesia) in patients with thermonociceptive impairments. They are important features of quantitative sensory testing (QST) protocols (Rolke, Baron, et al., 2006; Rolke, Magerl, et al., 2006) and are pivotal to the determination of sensory phenotypes (Baron et al., 2017; Raputova et al., 2017). Their role is particularly important in the diagnostic workup of neuropathies affecting small fibers (i.e., the subgroup of primary afferents responsible for thermonociception and autonomic functions) such as painful diabetic neuropathies (Terkelsen et al., 2017; Tesfaye et al., 2010).

Currently, clinical measurements of thermal detection thresholds are mainly performed using the method of limits (Fruhstorfer, Lindblom, & Schmidt, 1976), in which a continuous heating or cooling ramp (usually at a slow rate, 1°C/s in the case of the DFNS QST protocol (Rolke, Magerl, et al., 2006)) is applied to the skin of the patient who is instructed to press a button as soon as he/she feels a warm or cold sensation. The detection threshold is then considered to be the temperature reached at the moment the patient pressed the button. The method of limits has been known for a long time to be methodologically biased due to its reliance on the reaction time (Yarnitsky & Ochoa, 1991), which lead to an overestimation of the threshold value corresponding to the temperature change that occurred between detection and it's signalling by a motor response. This is problematic as reaction times are under the influence of decision and motor reaction response speeds which may be affected by factors irrelevant to the assessment of sensory discrimination, such as cognitive or motor impairments.

A methodologically sounder approach for threshold measurement is the method of levels or constant stimuli (Kingdom & Prins, 2010). A number of preselected stimulus intensities are presented a number of times in random order and the subject is asked whether he/she felt each stimulus. Unlike the method of limits, this approach is not biased by decision speed and motor function. Furthermore, this method enables the fitting of a psychometric function (probability of detection as a function of stimulus intensity) to the results, therefore moving thermal detection performance assessments from the outdated High Threshold Theory framework to that of the currently leading Signal Detection Theory (Kingdom & Prins, 2010). Whereas High Threshold Theory conceptualized detection as an ON/OFF process (below threshold, no detection occurs, above threshold detection always occurs), Signal Detection Theory sees detection as a probabilistic process (each stimulus intensity is associated with a probability of detection). This theoretical framework implies to redefine the threshold as the stimulus intensity for which detection probability equates 0.5. In addition to the threshold, the psychometric function is also defined by its slope, i.e. the rate at which detection probability changes around the value of the threshold. . Unfortunately, the method of levels has some important drawbacks. First, it is time consuming as it requires collecting responses to a large amount of stimuli (usually several hundreds) (Gescheider, 1997). Second, the range of stimulus intensities must be approximately centered on the actual threshold value and cover the transition range of detection probability.

To overcome these limitations, several adaptive procedures have been proposed. These procedures actively adjust the intensity of the presented stimuli depending on the previous responses of the subject (Kingdom & Prins, 2010). In the present study, we implemented for the first time the Psi method (a Bayesian adaptive algorithm proposed by Kontsevich and Tyler (1999)) to estimate the thresholds and slopes of the psychometric function for heat and cold detection. This algorithm associates each potential values of slope and threshold with a probability, updates this probability distribution based on the response recorded after each stimulus presentation (detected/not detected), and selects the next stimulus intensity so that the response to its presentation maximizes the entropy (i.e. the uncertainty around the values of slope and threshold) reduction.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
40 Years 至 79 Years(Adult, Older Adult)
性别
All
接受健康志愿者
是

入选标准

  • 未提供

排除标准

  • •Alcohol beverage intake >3 units/day
  • •Habitual substance abuse
  • •History of chemotherapy
  • •Scar or dermatological condition at the site of stimulation (forearm and hands, leg and foot)
  • •History of neurological, psychiatric or metabolic disorder other than Diabetes Mellitus (screening will be performed with the patient)
  • •Currently taking drugs that could induce neuropathy (screening will be performed with the patient)
  • •For healthy controls: Suffering of chronic pain

研究组 & 干预措施

Main study

Experimental

Several electrophysiological and behavioural tests will be performed to properly diagnose the patients/check that the healthy controls do not suffer of neuropathy.

干预措施: Thermal QST (cold and warm detection, heat pain) with the psi method (Diagnostic Test)

Main study

Experimental

Several electrophysiological and behavioural tests will be performed to properly diagnose the patients/check that the healthy controls do not suffer of neuropathy.

干预措施: Neurological examination (Diagnostic Test)

Main study

Experimental

Several electrophysiological and behavioural tests will be performed to properly diagnose the patients/check that the healthy controls do not suffer of neuropathy.

干预措施: Thermal QST (CDT, WDT, CPT, HPT) with the method of limits (Diagnostic Test)

结局指标

主要结局

Fitted psychometric functions for heat pain obtained with the psi method

时间窗: baseline

The alpha (threshold; °C) and beta (slope, °C\^-1) terms of the fitted logistic equation

Fitted psychometric functions for warm detection obtained with the psi method

时间窗: baseline

The alpha (threshold; °C) and beta (slope, °C\^-1) terms of the fitted logistic equation

Cold detection threshold (protocol of the German Research Network on Neuropathic Pain - DFNS)

时间窗: baseline

average of 3 measurement of the threshold with the method of limits, as described in the protocol of the German Research Network on Neuropathic Pain - DFNS

Cold pain threshold (protocol of the German Research Network on Neuropathic Pain - DFNS)

时间窗: baseline

average of 3 measurement of the threshold with the method of limits, as described in the protocol of the German Research Network on Neuropathic Pain - DFNS

Fitted psychometric functions for cold detection obtained with the psi method

时间窗: baseline

The alpha (threshold; °C) and beta (slope, °C\^-1) terms of the fitted logistic equation

Fitted psychometric functions for cold pain obtained with the psi method

时间窗: baseline

The alpha (threshold; °C) and beta (slope, °C\^-1) terms of the fitted logistic equation

Warm detection threshold (protocol of the German Research Network on Neuropathic Pain - DFNS)

时间窗: baseline

average of 3 measurement of the threshold with the method of limits, as described in the protocol of the German Research Network on Neuropathic Pain - DFNS

Heat Pain threshold (protocol of the German Research Network on Neuropathic Pain - DFNS)

时间窗: baseline

average of 3 measurement of the threshold with the method of limits, as described in the protocol of the German Research Network on Neuropathic Pain - DFNS