跳至主要内容
临床试验/NCT05253664
NCT05253664已完成不适用

Evaluation of the Effect of Woman-Centered Care Given in the Early Postpartum Period on Anxiety and Comfort Levels

Kutahya Health Sciences University1 个研究点 分布在 1 个国家目标入组 218 人开始时间: 2019年2月11日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
218
试验地点
1
主要终点
Pre-Test State, Trait Anxiety

研究概览

简要总结

H1a: There is a statistically significant difference in anxiety levels between women who received woman-centered care in the early postpartum period and women who received standard care.

H1b: There is a statistical difference in terms of comfort levels between women who received woman-centered care in the early postpartum period and women who received standard care.

H0a: There is no statistically significant difference in anxiety levels between women who received woman-centered care in the early postpartum period and women who received standard care.

H0b: There is no statistical difference in terms of comfort levels between women who receive female-centered care in the early postpartum period and women who receive standard care.

详细描述

The research was carried out as a single-blind and block randomized control. The research was conducted in a tertiary hospital in Turkey between February, 2019 and February 2020. The universe of the research consisted of women who gave birth by cesarean section. In the power analysis, the sample size was calculated as a minimum of 105 for each group, according to α:0.05 and 1-β= 0.95. Considering the possibility of loss or separation of the selected specimens during the conduct of the study, 240 women who met the inclusion criteria were assigned to the experimental (120) and control (120) groups.Due to the nature of the study, it was conducted as a single-blind randomized controlled trial.

The pre-test procedure was performed when the mothers' statuses were stabilized two hour after the admittance to the maternity service. The post-test procedure was conducted one hour before the discharge. Woman-centered care was provided to the experimental group, and standard care was provided to the control group.The women in the experimental and control groups were not told which group they were in. Each woman in the experimental group was given woman-centered care from the 2nd hour postpartum, and this process continued until the mother was discharged (mothers are discharged after 24 hours). The standard care provided by the hospital covers the basic postpartum care components. These components are the nutrition of the newborn and the protection of maternal and newborn health. A dynamic interaction was established between the women in the experimental group and the researcher in which woman-centered care was applied. Each woman in the experimental group was responsible for explaining herself, her own health behaviors, and her own needs and values.

"Descriptive Information Form", "Postpartum Comfort Scale" and "State-Trait Anxiety Inventory" were used as data collection tools.

Statistical analyses were performed using IBM SPSS (Statistical Package for Social Sciences) Statistics 22 software. Descriptive statistics (mean, standard deviation, frequency and percentage values) were used to assess the results. Kolmogorov-Smirnov test was used to review the goodness of fit to normal distribution.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Supportive Care
盲法
Single (Participant)

盲法说明

Participants didn't know which group they were allocated. The participants will be blind when they take Woman-Centered Care from investigators.

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
Female
接受健康志愿者
是

入选标准

  • •To receive woman-centered care
  • •To have cesarian section
  • •To have singleton birth
  • •To be within the early postpartum period (the first 24 hours)
  • •Not have complications childbirth
  • •Not have chronic diseases or mental disorders
  • •Older than 18 years
  • •To voluntary to participate
  • •To know how to read, write and speak in Turkish
  • •To stay within this study until the end
  • •To fully complete questionnaire
  • •To have a newborn with no complications
  • •To have a healthy baby

排除标准

  • •To receive standart care
  • •Not have cesarian section
  • •Having multiple birth
  • •Not to be within the early postpartum period (the first 24 hours)
  • •Having complications childbirth
  • •Having chronic diseases or mental disorders
  • •Younger than 18 years
  • •To refuse to participate
  • •Not knowing how to read, write and speak Turkish
  • •To leave early this study
  • •Not fill the questionnaire
  • •Having a newborn with complications
  • •Having a baby in need of medical care

研究组 & 干预措施

Woman-Centered Care Group

Experimental

Woman-centered care was given to the experimental group. At the time of the study, 6 women were discharged early, 4 women did not want to continue the study, and the babies of 1 women were admitted to the neonatal intensive care unit due to complications so these women were excluded from the study. The study was completed with 109 women in the experimental group.

干预措施: Woman-Centered Care Group (Behavioral)

Control Group

No Intervention

Standard care was given to the control group. At the time of the study, 2 women were discharged early, 7 women did not want to continue the study, and the babies of 2 women were admitted to the neonatal intensive care unit due to complications so these women were excluded from the study. The study was completed with 218 mothers, with 109 women in the control group.

结局指标

主要结局

Pre-Test State, Trait Anxiety

时间窗: 2nd postpartum hour

The State, Trait Anxiety Inventory consists of two subscales, being state and trait anxiety subscales, and 40 items. The State Anxiety Inventory determines how an individual feels at a certain moment and under certain conditions, and the Trait Anxiety Inventory on the other hand, generally determines how one feels. High scores indicate a high level of anxiety.

Systolic blood pressure

时间窗: 2nd postpartum hour

All of women were measured from the cubital fossa area using a digital sphygmomanometer. In order to ensure consistency in the measurement of physiological parameters, measurements were conducted on the women using the same devices. The first measurement of the physiological parameters of the women in both the experimental and control groups was recorded when they agreed to participate in the study. The measurement taken at the 2nd postpartum hour will be accepted. It will not be combined with the value measured at another time.

Body temperature

时间窗: 2nd postpartum hour

Body temperature was measured from the forehead using a non-contact thermometer. In order to ensure consistency in the measurement of physiological parameters, measurements were conducted on the women using the same devices. The first measurement of the physiological parameters of the women in both the experimental and control groups was recorded when they agreed to participate in the study. The measurement taken at the 2nd postpartum hour will be accepted. It will not be combined with the value measured at another time.

Pulse

时间窗: 2nd postpartum hour

Pulse was measured using a digital sphygmomanometer. In order to ensure consistency in the measurement of physiological parameters, measurements were conducted on the women using the same devices. The first measurement of the physiological parameters of the women in both the experimental and control groups was recorded when they agreed to participate in the study. The measurement taken at the 2nd postpartum hour will be accepted. It will not be combined with the value measured at another time.

Postpartum Comfort Scale

时间窗: 2nd postpartum hour

It is a five-point Likert-type scale that evaluates the physical, psychological, sociocultural and environmental comfort of mothers who had cesarean section and normal spontaneous delivery. The lowest and the highest scores that can be obtained from the 34-item scale are 34 and 170, respectively. High scores obtained from the scale indicate that the level of comfort increases.

Diastolic blood pressure

时间窗: 2nd postpartum hour

All of women were measured from the cubital fossa area using a digital sphygmomanometer. In order to ensure consistency in the measurement of physiological parameters, measurements were conducted on the women using the same devices. The first measurement of the physiological parameters of the women in both the experimental and control groups was recorded when they agreed to participate in the study. The measurement taken at the 2nd postpartum hour will be accepted. It will not be combined with the value measured at another time.

次要结局

  • Diastolic blood pressure(20th postpartum hour)
  • Post-Test State, Trait Anxiety(24th postpartum hour)
  • Post-Test postpartum Comfort Scale(24th postpartum hour)
  • Systolic blood pressure(20th postpartum hour)
  • Body temperature(20th postpartum hour)
  • Pulse(20th postpartum hour)

研究者

发起方
Kutahya Health Sciences University
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验