Detection of Pleural Effusion by Internal Thoracic Impedance Method
试验速览
- 阶段
- 不适用
- 发起方
- 入组人数
- 100
- 主要终点
- Internal thoracic impedance
研究概览
简要总结
Early detection of pleural effusion (PLE) would improve the treatment. However, preclinical detection of pleural effusion is often not possible.
Radiographic examination, widely used for detecting pleural effusion ,is not suitable for prolonged monitoring of patients at high risk of developing PLE especially ambulatory or at home The currently available methods for monitoring and early detection such as the measurement of pulmonary capillary wedge pressure or measurement by double indicator thermodilution, are not reliable enough and may themselves lead to complications.
Measuring internal thoracic impedance (ITI), the main component of which is lung impedance, is a noninvasive and safe method. PLE will be diagnosed in accordance with well-accepted clinical signs(dyspnea, cyanosis, pulmonary rales, crepitations, arterial hypoxemia) and roentgenological criteria
详细描述
Early detection of pleural effusion (PLE) would improve the treatment. However, preclinical detection of pleural effusion is often not possible.
Radiographic examination, widely used for detecting pleural effusion ,is not suitable for prolonged monitoring of patients at high risk of developing PLE especially ambulatory or at home (1-9).
The currently available methods for monitoring and early detection such as the measurement of pulmonary capillary wedge pressure or measurement by double indicator thermodilution, are not reliable enough and may themselves lead to complications(2-8).
Yu C-M et al.(9) recently reported successful prediction of CPE by a surgically implanted impedance plethysmograph integrated into a pacemaker . The system was shown to be sufficiently sensitive for cardiogenic pulmonary edema preceding. However this method is invasive and not suitable for wide use (9).
Therefore, these methods are seldom employed for the detection of PLE (3-7). Thus, a safe and accurate technique for early detection and monitoring of PlEf would be of great clinical value. The changes in the blood and extravascular fluid content in the lungs in humans and animals can be easily monitored using a noninvasive and totally safe procedure based on impedance plethysmography (5-12-). This method is based on the fact that the impedance of the lungs decreases with the increase in the fluid and free ions content in them (8,13,). However, it proved to be unsuitable for preclinical stage monitoring of PLE (2-8) for several reasons, mainly the low sensitivity of the existing impedance plethysmographs. This is due to the high skin-electrode contact resistance (13,14), which is of an order of magnitude high erthan the impedance of the lung.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 40 Years 至 90 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Inclusion criteria for study group will be as follows: patients 40-90 year old with pleural effusion on chest X-ray of different etiologies:
- •coronary heart disease-(CHD)
- •valvular heart disease
- •renal failure
- •infectious disease malignant diseases( all complicated by pleural effusion).
- •The control group will be comprised of patients 40-90years old without pleural effusion established by chest X-ray.
排除标准
- •The exclusion criteria will be respiratory failure due to diseases, wearing a pacemaker,thoracic deformation, pulmonary edema and embolism
结局指标
主要结局
Internal thoracic impedance
时间窗: 12 months