The Evaluation of Safety and Myopia Progression Control Using Novel Spectacle Lens
概览
- 阶段
- 不适用
- 干预措施
- 未指定
- 疾病 / 适应症
- Myopia
- 发起方
- HOYA Lens Thailand LTD.
- 入组人数
- 249
- 试验地点
- 5
- 主要终点
- Axial length
- 状态
- 进行中(未招募)
- 最后更新
- 上个月
概览
简要总结
The goal of this clinical trial is to test Novel spectacle lenses in myopic children. The main question it aims to answer are: safety and efficacy of the lenses. Participants will be asked to wear spectacles and participate in eye exams and questionnaires. Researchers will compare Novel spectacle lenses and general single vision spectacle lenses to see if the Novel spectacle lenses correct myopic ametropia, slow the progression of myopia and axial elongation.
详细描述
This is a 3-year prospective, multicenter, randomized, and single-masked\*, parallel-group controlled clinical study. The purpose of this study is to evaluate the safety and efficacy of wearing Novel spectacle lenses to correct myopic ametropia, slow the progression of myopia and axial elongation in myopic children as compared to the use of single vision spectacles lenses. The treatment arms are: * Model A Novel spectacle lens * Model B Novel spectacle lens * Single vision spectacle lens Single-masked: The investigator responsible for conducting ocular data measurements related to the primary and secondary endpoints will be masked. The participants will not be informed the treatment arm during the clinical trial.
研究者
入排标准
入选标准
- •Participant and parent (or guardian) are able and willing to provide consent
- •Participant and parent (or guardian) ensure to attend required study visits and adhere to participant requirements
- •Parent or guardian understands and accepts random allocation of grouping, and that participant and parent (or guardian) will not be told which group participant is allocated to
- •Participant willing to wear the study spectacles lens for a minimum of 12 hours per day for the duration of the study
- •Age at time of parent or guardian consent and participant assent: 7 - 13 years old
- •Spherical equivalent cycloplegic autorefraction: -1.00 to -7.00 D in each eye.
- •Cycloplegic autorefraction astigmatism of 1.50 D or less in each eye
- •Cycloplegic autorefraction anisometropia of 1.50 D or less
- •Monocular best corrected distance visual acuity (BCDVA) equal to or better than logMAR 0.10 in each eye.
排除标准
- •Participant is allergy to fluorescein, benoxinate, proparacaine, tropicamide or cyclopentolate eye drops
- •Any ocular and systemic abnormalities might be expected to affect visual functions or refractive development
- •(a) Have received treatment of myopic control pharmaceutical medication (e.g., atropine) or light fundus illuminance therapy (e.g., repeated red light therapy) within 6 months prior to entry into this study. (b) Have received treatment of myopia control such as contact lenses, orthokeratology lenses etc., progressive addition lenses, bifocal lenses, within 3 months. (c) Have received treatment of myopia control such as defocus spectacle lenses (difference between both eye's non-cycloplegic autorefraction and lens-meter results of the respective lenses are equal or less than 0.50 D SER) etc. within one month prior to entry into this study.
- •Participant with clinically significant strabismus (including intermittent tropia)
- •Medical history of binocular vision abnormalities
- •Participant with amblyopia
- •Participation in a clinical trial within 30 days prior to entry into this study or during participation
- •Previous intraocular surgery
- •Participant who, in the judgment of the Investigator, presence of any emotional, physiologic, or anatomical condition which may preclude participation in this study or provide an inappropriate landscape for the intended study treatment.
- •Any medical treatment or medication which might have an influence on vision or interfere with study assessments
结局指标
主要结局
Axial length
时间窗: 24 months
The difference of Axial length changes over 24 months between treatment groups in low and moderate myopia (-1.00 D to -5.00 D) participants.
Spherical equivalent cycloplegic autorefraction
时间窗: 24 months
The difference of spherical equivalent cycloplegic autorefraction changes over 24 months between treatment groups in low and moderate myopia (-1.00 D to -5.00 D) participants
次要结局
- Axial length(36 months)
- Spherical equivalent cycloplegic autorefraction(36 months)