Impact of Pacing Output and Cycle Length on QRS Morphology in Ablation of Premature Ventricular Contractions
试验速览
- 阶段
- 不适用
- 入组人数
- 50
- 试验地点
- 2
- 主要终点
- Template Matching with clinical PVC
研究概览
简要总结
Current recommendations for pacemapping are based on expert opinion and animals models. Present study sought to evaluate the influence of different parameters of pacemapping on QRS morphology. Pacemapping is performed with different cycle length (fixed burst vs. coupling interval) and stimulation output (maximum output vs. threshold) and resulting QRS complexes are compared to clinical PVC and the standard of care to determine the optimal parameter setting in pacemapping.
详细描述
Pacemapping is a common technique to determine to origin of ventricular ectopy during catheter ablation of premature ventricular contractions (PVC). During the pacemapping process an electrical pacing stimulus is applied via the ablation catheter and the resulting QRS complex is compared the clinical target PVC. The higher the consistency between the stimulated QRS complex and the clinical PVC, the nearer the catheter is located to the origin of ectopy.
Current recommendations for the execution of pacemapping are based on expert opinion and animals models. The investigators sought to assess for the first time in a clinical real life setting the different parameters for pacemapping (i.e. Cycle length and stimulation output). Therefore during the pacemapping process in routine PVC ablation pacing is performed with different cycle length (fixed burst vs. coupling interval of PVC) and different electrical output (maximum output vs. stimulation threshold). The resulting QRS morphologies are on the one hand compared to the ablation target (clinical PVC) and on the other hand to the suggest standard of care (Coupling interval at pacing threshold) to determine the optimal setting of parameters in pacemapping.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •All patients undergoing PVC ablation
排除标准
- •patients <18 years
- •patients not able to consent
- •pregnancy
- •contraindication for PVC ablation
- •unavailability of vascular access
- •patients with complex congenital heart disease
- •expected hemodynamical instability during pacemapping
结局指标
主要结局
Template Matching with clinical PVC
时间窗: Immediately during PVC ablation. No follow up intended.
Different pacing settings are applied in order to determine the optimal Consistency between paced QRS complex and clinical PVC
次要结局
未报告次要终点