Evaluation of the Dialyzer Vitamin E Coated Effect Inflammatory State of Patients in ESRD and Its Clinical Benefits in Terms of Anemia
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- Hemotech
- 入组人数
- 120
- 试验地点
- 2
- 主要终点
- Evolution of the well-known inflammatory marker : High sensibility-CRP
研究概览
简要总结
Evaluation of the effect of a vitamin E coated high flux polysulfone dialyzer on the inflammatory state of patients' end stage renal disease and its clinical benefits in terms of anemia Objectives : To assess the benefits of a vitamin E coated polysulfone membrane on the micro-inflammatory state of chronic dialysis patients Prospective multicenter controlled and randomized study Number of patients : 120 patients (60 patients per group)
详细描述
Coordinator : Pr JP.CRISTOL Montpellier hospital university Rational : The hemodialyzed patients are subject to inflammation due to their pathologies and to the technique. The VIE dialyzer polysulfon coated to vitamin E has been shown to have a favourable action on inflammation and anemia. The investigators want to highlight the influence of vitamine E graft using as controlled dialyzer a similar polysulfon from the same manufacturer without vitamin E.
Medical device : ViE High flux dialyzer -> vitamin E coated polysulfone membrane manufactured by Asahi Kasei Medical, with CE mark and intended for use in hemodialysis for the patient suffering from acute or chronic renal failure Controlled medical device : Leoceed H high flux dialyzer : polysulfone membrane manufactured by Asahi Kasei Medical, with CE mark and intended for use in hemodialysis for patient suffering from acute or chronic renal failure Objectives : To assess the benefits of a vitamin E coated polysulfone membrane on the micro-inflammatory state of chronic dialysis patients Primary end point : Evolution of the well-known inflammatory marker : High sensibility-CRP Secondary end point : Evolution of the following inflammatory markers : IL-6, TNFa, fibrinogen, antibodies anti- LDLox Evolution of Hemoglobin and ERI Evolution of Nutritional parameters : albumin and pre albumin Study design : Prospective multicenter controlled and randomized protocol study Duration : 12 months Number of patients : 120 patients : 60 patients per group 120 patients : 60 patients per group Adult ESRD patient, whatever the origin, treated by HD, thrice a week for about 4 hours and hemo dynamically well balanced Inclusion criteria : Dialyzed patient on synthetic high flux dialyzer for 3 months Patient with a vascular access allowing a blood flow rate ≥ 250 ml/min Patient with micro inflammation, i.e an average CRP between 5 and 20 mg/L on the two last check-up of CRP Patient informed of the study and having signed the inform consent. Exclusion criteria : Underage patient Subjects who are pregnant or planning to become pregnant during the study Patient with an infection influencing the Hb level
Patient with an Iron deficiency showed with :
Transferin saturation < 20 % and/or Ferritin < 100 µg/L, Hemo transfusion in the last two months Patient treated by HF, HDF, biofiltration Patient with infectious risks Subjects who participated in a clinical study involving dialyzers in the last two months
Criteria of exit :
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Adult ESRD patient, whatever the origin, treated by HD, thrice a week for about 4 hours and hemo dynamically well balanced
- •Dialyzed patient on synthetic high flux dialyzer for 3 months
- •Patient with a vascular access allowing a blood flow rate ≥ 250 ml/min
- •Patient with micro inflammation, i.e an average CRP between 5 and 20 mg/L on the two last check-up of CRP
- •Patient informed of the study and having signed the inform consent.
排除标准
- •Underage patient
- •Subjects who are pregnant or planning to become pregnant during the study
- •Patient with an infection influencing the Hb level
- •Patient with an Iron deficiency showed with :
- •Transferin saturation < 20 % and/or Ferritin < 100 µg/L,
- •Patients having received an Hemo transfusion in the last two months
- •Patient treated by HF, HDF, biofiltration
- •Patient with infectious risks
- •Subjects who participated in a clinical study involving dialyzers in the last two months
研究组 & 干预措施
ViE High flux dialyzer
vitamin E coated polysulfone membrane manufactured by Asahi Kasei Medical, with CE mark and intended for use in hemodialysis for the patient suffering from acute or chronic renal failure
干预措施: VIE high flux dialyzer (Device)
Leoceed H high flux dialyzer
polysulfone membrane manufactured by Asahi Kasei Medical, with CE mark and intended for use in hemodialysis for patient suffering from acute or chronic renal failure
干预措施: Leoceed H high flux dialyzer (Device)
结局指标
主要结局
Evolution of the well-known inflammatory marker : High sensibility-CRP
时间窗: one year with a follow-up of three months
Decrease of the CRP marker due the use of vitamin E coated dialyzer
次要结局
- Inflammatory markers(one year with a follow-up of three months)
- Anemia parameters(one year with a follow-up of three months)
- Nutritional Parameters(one year with a follow-up of three months)
