Pilot Evaluation for SMartphone-adaptable Artificial Intelligence for PRediction and DeTection of Left Ventricular Systolic Dysfunction

Yale University2 个研究点 分布在 1 个国家目标入组 10 人开始时间: 2023年9月13日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
10
试验地点
2
主要终点
Successful detection of asymptomatic LVSD by AI-ECG

研究概览

简要总结

The goal of this pilot study is to evaluate the prospective performance of an image-based, smartphone-adaptable artificial intelligence electrocardiogram (AI-ECG) strategy to predict and detect left ventricular systolic dysfunction (LVSD) in a real-world setting.

详细描述

The SMART-LV pilot study will be a prospective cohort study in outpatient clinics at the Yale New Haven Hospital. Participants who have undergone a 12-lead electrocardiogram (ECGs) with either a high (≥80%) or low (<10%) probability of LVSD on AI-ECG algorithm, but without an echocardiogram done in the clinical setting for at least 90 days after the ECG, will be identified by electronic health record (EHR) and invited for a limited echocardiogram/cardiac ultrasonogram for assessing LV ejection fraction. The goal of the study is to evaluate the feasibility of recruiting patients and performing the study after pursuing a screening on 12-lead ECGs. The procedure currently used for detection of LVSD, echocardiograms, are inaccessible and expensive. Therefore, while AI-ECG-based algorithms using a smartphone- or web-based application can broaden access to screening, a thorough evaluation for this indication is needed before clinical adoption. The investigators intend to use the results as pilot data for sample size and drop-off rate estimation for a subsequent larger prospective cohort study aimed at validating the performance characteristics of the model in a screening setting.

The validation of this accessible ECG-based screening strategy, that can be directly used by clinicians using a smartphone or web-based application, can transform the early identification of LVSD before the development of symptoms, thereby allowing broader utilization of evidence-based therapies to prevent symptomatic heart failure and premature death.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Device Feasibility
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Provision of signed and dated informed consent form.
  • Stated willingness to comply with all study procedures and availability for the duration of the study

排除标准

  • Patients who have undergone a prior echocardiogram.
  • Patients with a prior diagnosis of left ventricular dysfunction, based on a documented low ejection fraction (EF) in the medical record.
  • Patients with an intermediate predicted probability of low EF (10 to 80%)
  • Patients with a prior diagnosis of heart failure as determined by International Classification of Diseases-10 diagnosis code for heart failure.
  • Research opt-out patients

结局指标

主要结局

Successful detection of asymptomatic LVSD by AI-ECG

时间窗: During study visit approximately 50 minutes

Device feasibility of AI-ECG will be evaluated by comparing the proportion of patients with LVSD on echocardiography among those with a high predicted probability of LVSD on an AI-ECG screen compared with the proportion of patients with LVSD on echocardiography in those with a negative AI-ECG screen. Higher proportions indicate successful detection of asymptomatic LVSD compared with routine clinical care.