跳至主要内容
临床试验/NCT02977247
NCT02977247已完成不适用

ARM 2: A Prospective, Multicenter, Multi-arm, Clinical Case Collection Program to Acquire Breast Image Data and Establish an Image Library of Exams for Use in Future Research Studies, Training, and Product Development Efforts.

Delphinus Medical Technologies, Inc.10 个研究点 分布在 1 个国家目标入组 1,150 人开始时间: 2016年12月6日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
1,150
试验地点
10
主要终点
No Breast Cancer

研究概览

简要总结

The SoftVue™ is a whole breast ultrasound system with an automated scanning curvilinear ring-array transducer that employs UST. It is currently cleared under FDA 510(k) K123209 and K142517 for use as both a B-mode ultrasonic breast imaging system and color imaging of transmission data (sound speed and attenuation). SoftVue™ is not intended to be used as a replacement for screening mammography.

SoftVue uses non-ionizing ultrasound energy to generate tomographic image volumes of the whole breast. While the patient lays prone on a padded table with one breast comfortably submerged in a bath of warm water, a ring-shaped transducer, 22 cm in diameter, encircles the breast and pulses low-frequency sound waves through the water and into the breast tissue. More than 2000 elements in the curvilinear transducer's 360 degree array emit and receive ultrasound signals to analyze echoes from the breast anatomy in all directions, from the chest wall to the nipple. Not only does SoftVue capture data from the reflection of the sound waves off of tissue boundaries and structures within the breast, but because the transducer surrounds the whole breast, SoftVue also captures signals that are transmitted through the breast. This additional transmission data enhances the visualization of the anatomic structure of the breast tissue and is not currently available in any other commercially marketed breast ultrasound device.

This prospective, multicenter, multi-arm, clinical case collection program is IRB-approved and will be conducted in compliance with Good Clinical Practice, the Declaration of Helsinki and all applicable regulatory requirements. Arm 2 aims to collectively enroll up to 1,000 women at a total of up to 8 clinical sites. The design of Arm 2 in this protocol is strictly limited to case collection and is non-interventional; any investigational and/or statistical plans for future analyses will be prepared and registered separately, if they are applicable to the requirements of FDAAA 801.

Arm 2 is limited to the cohort of diagnostic female patients of any breast density composition category, who have been recommended for a breast biopsy (BI-RADS 4 or 5) after diagnostic imaging, or who have confirmed imaging findings. Matched sets of diagnostic imaging and SV exams, from the same patient, demographic information, and clinical outcome data, will be collected during diagnostic workup. Ultrasound characteristics for all types of lesions, whether they are benign or malignant, will be collected as well as objective and subjective breast density composition data. Ultrasound image data may be acquired with modified SoftVue devices, which have passed safety and quality evaluations per Delphinus' quality management system (QMS) and satisfy design change control standards, at select clinical sites in accordance with 21 CFR 812.2 (b), as a routine part of feasibility, validation, and verification testing for engineering and product development purposes.

The exams and clinical data accumulated in this prospective case collection (PCC) protocol will populate a database from which future investigations may be designed for peer reviewed publication, development of user training curricula, building teaching case, and creating new marketing materials for SoftVue.

详细描述

MEDICAL DEVICES:

  • SoftVue™ (SV) automated whole breast ultrasound system, 510(k) Cleared for B-Mode ultrasound breast imaging, manufactured by Delphinus Medical Technologies.
  • SoftVue™ with device modifications (software, hardware, user-interface), safety-tested for human use to complete feasibility, verification, and validation testing as a routine part of product development and performed in accordance with FDA 21 CFR 812.2 (b), manufactured by Delphinus Medical Technologies.
  • Full-field digital mammography (FFDM), FDA Approved for breast screening and diagnosis, various manufacturers. (If clinically indicated)
  • Digital breast tomosynthesis (DBT), FDA Approved for breast screening and diagnosis, various manufacturers.
  • Handheld Ultrasound (HHUS), FDA-Cleared for diagnostic breast imaging, various manufacturers. (If clinically indicated)
  • Other diagnostic tests and medical device examinations of the breast, including, but not limited to MRI, BSGI, PET, biopsy, and elastography, on the order of a licensed physician, when clinically indicated.

OBJECTIVES:

  • Primary: To establish a library of cases for use in future SoftVue™ research studies, user training, and marketing.
  • Secondary: Determine the frequency and severity of adverse events (AEs) to further evaluate the safety of SoftVue.

ENDPOINTS:

研究设计

研究类型
Observational
观察模型
Other
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
Female
接受健康志愿者

入选标准

  • 未提供

排除标准

  • 未提供

结局指标

主要结局

No Breast Cancer

时间窗: Current Diagnostic Evaluation Episode, 0 to 60 Days

Non-Cancer cases, confirmed by normal or negative breast imaging findings or concordant breast biopsy with benign pathology.

Breast Cancer

时间窗: Current Diagnostic Evaluation Episode, 0 to 60 Days

Cancer cases, confirmed by breast biopsy with malignant pathology

次要结局

未报告次要终点

研究者

申办方类型
Industry
责任方
Sponsor

研究点 (10)

Loading locations...

相似试验