临床试验/NCT01242306
NCT01242306已完成1 期

Head-to-Head Comparison of Endothelial Dysfunction (Bare Metal Stent vs Sirolimus Eluting Stent) in the Same Patient With Multiple Coronary Artery Lesions

Azienda Ospedaliera San Camillo Forlanini1 个研究点 分布在 1 个国家目标入组 25 人开始时间: 2009年3月最近更新:
适应症
干预措施
相关药物

试验速览

阶段
1 期
状态
已完成
入组人数
25
试验地点
1
主要终点
evaluation of endothelial dysfunction at 6 months follow-up by measuring the change in vessel diameter in 5 points of the stent and peri-stent site after infusion of acetylcholine

研究概览

简要总结

This is a prospective, randomised study to compare the endothelial dysfunction of BMS vs SES, both implanted in the same patient with multiple de novo coronary artery lesions undergoing elective PCI. The primary end point will be the evaluation of endothelial dysfunction at 6 months follow-up by measuring the change in vessel diameter in 5 points of the stent and peri-stent site after infusion of acetylcholine.

详细描述

This prospective, randomised study compares the endothelial dysfunction of BMS vs SES, both implanted in the same patient with multiple de novo coronary artery lesions undergoing elective PCI. From february 2009 to may 2009 we aim to enroll 20 patients with at least two de novo significant angiographic stenoses in different coronary segments who will have similar diameter and length. The primary end point will be the evaluation of endothelial dysfunction at 6 months follow-up by measuring the change in vessel diameter in 5 points of the stent and peri-stent site after infusion of acetylcholine.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 90 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • stable angina pectoris
  • at least two significant angiographic stenoses in different native coronary vessels or in the same vessel but two different ramifications with similar diameter
  • non-surgical patients

排除标准

  • acute coronary syndromes
  • myocardial infarction within 3 months from event
  • clinical or angiographic coronary vasospasm
  • coronary angiographic findings of a fresh thrombus in the initial angiography (filling defect proximal to or involving the stenosis)
  • coronary anatomy unsuitable for for intracoronary acetylcholine testing (left main coronary artery disease >30%, surgical three vessel disease or other anatomical considerations that make it unsafe to perform intracoronary studies)
  • progression of lesions or development of de novo lesions in nontarget lesions or vessels on follow-up angiography
  • patients with a vessel diameter < 2,50 mm and length lesions <10 and >30 mm.
  • patients with vessel diameter difference (SES vs BMS) >0,5mm and length difference of the stenosis >50%
  • lesions treated with balloon injury <10 mm or >50 mm in length
  • severe left ventricular (LV) systolic dysfunction
  • bifurcation/ostial
  • presence of an unhealed dissection identified by intravascular ultrasound (IVUS) performed at the end of the study.
  • angiographic restenosis in follow-up angiography
  • patients with severe risk factors for endothelial dysfunction: severe renal failure, life expectancy less than 1 year, uncontrolled diabetes, uncontrolled hypertension (systolic blood pressure >180mmHg), currently smoking, uncontrolled hypercholesterolemia (total cholesterol >240mg/dl)
  • any contraindication/nontolerance to the use of aspirin, heparin and/or clopidogrel
  • lack of consent to participate

研究组 & 干预措施

BMS arm

Placebo Comparator

bare metal stent arm

干预措施: intracoronary infusion of acetylcholine (Drug)

SES arm

Active Comparator

sirolimus eluting stent arm

干预措施: intracoronary infusion of acetylcholine (Drug)

结局指标

主要结局

evaluation of endothelial dysfunction at 6 months follow-up by measuring the change in vessel diameter in 5 points of the stent and peri-stent site after infusion of acetylcholine

时间窗: 6 months

evaluation of change in vessel diameters (vasoconstriction or vasodilatation) in proximal and distal stent territories, after intracoronary acetylcholine infusion, having as reference the baseline diameters, for the BMS artery vs the SES artery

次要结局

未报告次要终点

研究者

申办方类型
Other

研究点 (1)

Loading locations...

相似试验