Feasibility, Safety, Cost-effectiveness, and Environmental Impact of Reprocessed Ablation Catheters in Pulmonary Vein Isolation
试验速览
- 阶段
- 不适用
- 状态
- 招募中
- 发起方
- 入组人数
- 200
- 试验地点
- 1
- 主要终点
- Pulmonary Vein Isolation Procedure Duration
研究概览
简要总结
This study evaluates whether re-sterilized (reprocessed) ablation catheters are as effective and safe as new ablation catheters when used for pulmonary vein isolation in patients with atrial fibrillation. Adult patients scheduled for catheter ablation will be randomly assigned to undergo the procedure using either a new catheter or a re-sterilized catheter, with identical procedural techniques applied in both groups. The study will compare procedural efficiency, safety, costs, and environmental impact between the two approaches. The results may support more sustainable and cost-effective use of medical devices in cardiac electrophysiology.
详细描述
This is a prospective, randomized, controlled non-inferiority trial comparing re-sterilized (reprocessed) and new ablation catheters for pulmonary vein isolation in patients with atrial fibrillation. The study will be conducted at University Hospital Dubrava, a high-volume tertiary center for cardiac electrophysiology.
Patients scheduled for pulmonary vein isolation will be randomized in a 1:1 ratio using a computer-generated sequence to undergo ablation with either a new or a re-sterilized catheter. All procedures will be performed by experienced electrophysiologists in accordance with standard institutional practice.
Procedure duration will be measured from transseptal puncture to completion of ablation of all pulmonary veins. Additional procedural parameters related to ablation delivery, including duration and number of energy applications, total ablation time, and other procedural timing characteristics, will also be recorded. Fluoroscopy time and radiation dose, expressed as dose-area product (DAP), will be recorded automatically.
Catheter performance will be assessed based on achievement of complete pulmonary vein isolation, the number of energy applications per pulmonary vein, and procedural assessment of catheter integrity, flexibility, and electrical properties.
Procedural safety will be evaluated by monitoring peri-procedural and post-procedural adverse events, including pericardial effusion, stroke, vascular complications, and death. Laboratory markers of inflammation, infection, and hemolysis will be obtained at predefined time points before and after the procedure. Blood cultures will be collected after the procedure to assess potential infectious complications.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Age ≥ 18 years
- •Paroxysmal or persistent atrial fibrillation documented by ECG or Holter ECG monitoring
- •Indication for pulmonary vein isolation according to current clinical guidelines
- •Written informed consent
排除标准
- •Severe valvular heart disease
- •Significant structural heart disease that precludes pulsed field ablation (PFA)
- •Pregnancy or breastfeeding
- •Life expectancy < 12 months
研究组 & 干预措施
Reprocessed Catheter (Experimental)
Participants will undergo pulmonary vein isolation using a reprocessed electroporation ablation catheter. The catheter has undergone validated cleaning, re-sterilization, and functional testing in accordance with applicable regulatory and safety standards. Procedural technique, energy delivery protocol, and peri-procedural management will be identical to those used in the comparator arm.
干预措施: Participants will undergo pulmonary vein isolation using pulsed field ablation (PFA). The intervention consists of the use of either a reprocessed electroporation ablation catheter or a new electropor (Procedure)
New Catheter (Active Comparator)
Participants will undergo pulmonary vein isolation using a new electroporation ablation catheter. Procedural technique, energy delivery protocol, and peri-procedural management will be identical to those used in the experimental arm.
干预措施: Participants will undergo pulmonary vein isolation using pulsed field ablation (PFA). The intervention consists of the use of either a reprocessed electroporation ablation catheter or a new electropor (Procedure)
结局指标
主要结局
Pulmonary Vein Isolation Procedure Duration
时间窗: From the start of the index ablation procedure until its completion.
Procedure duration, expressed in minutes, measured from transseptal puncture to completion of ablation of all pulmonary veins. Additional procedural parameters, including duration of individual procedural segments, total ablation time, number and duration of energy applications, and other time-related procedural characteristics, will also be recorded.
次要结局
- Procedural Catheter Performance Parameters(From the start of the index ablation procedure until its completion)
- Medical Waste Generated Per Procedure(Periprocedural)
- Fluoroscopy Time(From the start of the index ablation procedure until its completion)
- Radiation Dose (Dose-Area Product)(From the start of the index ablation procedure until its completion)
- Incidence of Peri- and Post-Procedural Complications(Up to 30 days following the index ablation procedure)
- Direct Procedural Costs Per Patient(Periprocedural)
- Estimated Carbon Footprint Per Procedure(From the start of the index ablation procedure until its completion.)
研究者
Ivan Zeljkovic
Principal Investigator and Head of Diagnostic and Therapeutic Department for Cardiac Electrostimulation and Electrophysiology
University Hospital Dubrava