跳至主要内容
临床试验/NCT00387244
NCT00387244终止不适用

Efficacy of the Precision Spinal Cord Stimulation System as Salvage Therapy for Patients With Chronic Intractable Pain of the Trunk and or Limbs Who Have Failed Treatment With an Intraspinal Infusion Pump or Other Spinal Cord Stimulation Device

Boston Scientific Corporation2 个研究点 分布在 1 个国家目标入组 7 人开始时间: 2006年8月最近更新:
适应症

试验速览

阶段
不适用
状态
终止
入组人数
7
试验地点
2
主要终点
Percent of Subjects With a Significant Reduction in Pain During the Temporary Trial

研究概览

简要总结

The primary objective of this study is to evaluate the efficacy of spinal cord stimulation using the Precision implantable neurostimulation device for chronic and intractable pain of the trunk and or limbs in patients who have failed treatment with an intraspinal infusion pump or other SCS system.

详细描述

Chronic pain is managed by the sequential application of various strategies: medications, anesthetic injections, ablation, surgery, implantable intraspinal infusion pumps, and spinal cord stimulation. For a significant number of patients, however, these treatments are inadequate or cannot be tolerated. Those patients require another option for pain relief.

The therapy afforded by spinal cord stimulators is dependent on overlapping paresthesia with the painful areas. One of the leading reasons for explant of SCS systems (not including device failure or surgical complication) is the complaint of inadequate pain relief due to poor coverage of the painful area. Mounting evidence suggests that the clinical efficacy afforded by SCS varies with each manufacturer's technology. For instance, previously-implanted SCS patients report more complete coverage, better pain relief, and a more pleasant sensation associated with the paresthesia of the Precision system. The tight lead spacing and current fractionalization achievable with the Precision system may provide pain relief after failure with another SCS system.

This study will assess pain relief with the Precision system for patients with chronic, intractable pain who are refractory to treatment with other types of SCS systems and/or implantable intraspinal infusion pumps. Because Precision allows unique programming combinations not possible with other systems, it is expected that subjects will enjoy significant pain relief.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Have chronic and intractable neuropathic pain of the trunk and/or limbs of moderate to severe intensity and have failed treatment with an intraspinal infusion pump or other SCS device. Determination of failure of treatment will be based on subject feedback. Subjects with an active intraspinal infusion pump but with inadequate pain control will be allowed to participate;
  • Be 18 years of age or older;
  • Be an appropriate candidate for the surgical procedures required for this study;
  • Be willing and able to comply with all study related procedures and visits;
  • Be capable of reading and understanding patient information materials and giving written informed consent.

排除标准

  • Have failed immediate past treatment with an intraspinal infusion pump or other SCS device because of technical reasons associated with the device such as unresolved lead migration, battery depletion, etc.;
  • Have any evidence of neurologic instability requiring surgery;
  • Have any significant medical condition that in the opinion of the investigator may interfere with the conduct of the study or may adversely affect the subject's safety during the study;
  • Have any other active implantable device with the exception of a intraspinal infusion pump for pain medications;
  • Are pregnant or lactating or planning to become pregnant in the next year;
  • Have participated in any investigational drug or device trial in the last 4 weeks or plan to participate in any other investigational drug or device trial while on this study.

结局指标

主要结局

Percent of Subjects With a Significant Reduction in Pain During the Temporary Trial

时间窗: Baseline and at End of trial (approximately 5 days)

次要结局

未报告次要终点

研究者

申办方类型
Industry
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验