Low-level Laser Therapy With a 635nm Diode Laser Affects Orthodontic Mini-implants Stability. A Randomized Clinical Split-Mouth Trial.
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 20
- 试验地点
- 1
- 主要终点
- stability of orthodontic mini-implants
研究概览
简要总结
The study aimed to clinically estimate an influence of a 635nm diode laser on the primary and secondary stability of orthodontic mini-implants placed in a maxilla, to assess mini-implants failure rate (mini-implant loss) and to evaluate a pain level after the treatment. The randomized clinical split-mouth trial included 15 subjects, 30 implants (Dual Top Anchor System, Seoul, Korea) with a diameter 1.4mm and length of 10mm. Mini-implants were placed in the area of the attached gingiva between the second premolar and first molar teeth 2 mm below the mucogingival junction of both sides of the maxilla in 20 patients (13 women and 7 men; age: 32.5 ± 6.1 years).
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- Single (Investigator)
入排标准
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •patients with class II malocclusion defect requiring lateral maxillary teeth distillation based on the use of orthodontic mini-implant;
- •the patients were treated first time using fixed orthodontic appliance;
- •no systemic diseases;
- •were not using anti-inflammatory drugs;
排除标准
- •had used antibiotics in the previous 24 months;
- •had history of radiotherapy,
- •taking bisphosphonate medication
结局指标
主要结局
stability of orthodontic mini-implants
时间窗: 60 days
The mini-implants stability was estimated employing a Periotest device (Medzintechnik Gulden e K, Modautal, Germany). The Periotest measurement system includes the sound formed from contact between an object and a metallic tapping bar in a handpiece, which is electromagnetically driven and electronically verified. The Periotest response detection is analyzed through a fast Fourier transform (FFT) algorithm. Simply put, the Periotest answer to tapping is estimated by an accelerometer and then analyzed. The signal generated by tapping is then transformed to a value called the Periotest value (PTV), which depends on the damping characteristics of the peri-implant tissue. \[27\] The Periotest Test values (PTVs) are based on a numerical scale ranging from -8 to +50, defined by mathematical computation. The lower Periotest values indicate higher implant stability and thereupon the higher absorption effect of the target objects.
次要结局
- Pain level(24 hours)
- mini-implants loss(60 days)
研究者
Jacek Matys
Principal Investigator
Wroclaw Medical University
