Comparison of Intraoperative Performance and Incision Morphology Using Three Injector Devices : Randomized, Clinical Trial

Iladevi Cataract and IOL Research Center0 个研究点目标入组 120 人开始时间: 2013年12月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
120
主要终点
Incision enlargement in mm

研究概览

简要总结

This randomized clinical trial compares subjective performance during Intraocular lens (IOL) implantation, as well as incision enlargement and anterior segment morphology on OCT when IOL implantation was performed during microcoaxial phacoemulsification through a 2.2mm incision using one of three injectors :

Manual screw type (Monarch III), Manual plunger type (Royale) and motorised injector (Autosert). Further, the investigators also looked at incision integrity by comparing ingress of trypan blue from the ocular surface into the anterior chamber.

详细描述

In this randomized, clinical trial, three types of injectors were compared :

  1. Manual, screw type injector (Monarch III)
  2. Manual, plunger type injector (Royale, ASICO)
  3. Motorized injector (Autosert, Alcon)

Having performed a phacoemulsification through 2.2mm incision, IOL implantation was performed using a D cartridge and one of three injectors which was decided in a randomized fashion.

The investigators evaluated incision enlargement at following points : at the end of phacoemulsification, and then, at the end of IOL implantation The investigators also looked at trypan blue ingress into the anterior chamber from the ocular surface. At 1 day, 1 week, and 1 month after surgery anterior segment OCT morphology was also studied.

further, the surgeon was asked to subjectively grade the ease of implantation with each injector

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Single Group
主要目的
Treatment
盲法
Single (Participant)

入排标准

年龄范围
40 Years 至 85 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients undergoing phacoemulsification for age-related uncomplicated cataracts through a 2.2mm incision.
  • Nuclear or corticonuclear of grade 2 to 4 according to the Lens Opacities Classification System (LOCS III)

排除标准

  • Glaucoma,
  • shallow anterior chamber (depth <2.1mm),
  • prior ocular trauma or surgery,
  • maximal pupillary dilatation <6mm,
  • high myopia (axial length >25mm),
  • posterior polar cataracts,
  • dense cataracts, and
  • an IOL power <19.0 D or >25.0 D

结局指标

主要结局

Incision enlargement in mm

时间窗: 1 minute after surgery

次要结局

  • Trypan Blue ingress into the anterior chamber in log units(1 minute after surgery)
  • Incision morphology - qualitative(1 day, 1 week and 1 month after surgery)